ENTRY D0070 20040217 0000D007000000001 SUBENT D0070001 20040217 0000D007000100001 BIB 10 13 D007000100002 TITLE A method for the measurement of the cross-sections for D007000100003 the production of radioisotops by charged particles D007000100004 from a cyclotron D007000100005 AUTHOR (I.A.Watson,S.L.Waters,D.K.Bewley,D.J.Silvester) D007000100006 INSTITUTE (2UK HHL) D007000100007 REFERENCE (J,NIM,106,231,1973) D007000100008 FACILITY (CYCLO) D007000100009 METHOD (ACTIV,STTA,EXTB) D007000100010 DECAY-DATA The authors used data from the Nuclear Data Sheets, D007000100011 B2-6-72, 1968 (Academic Press, New York) D007000100012 STATUS (TABLE) Table 2,3 from main ref. D007000100013 ERR-ANALYS (DATA-ERR) Standard deviation from overlaping D007000100014 HISTORY (20031217C) SD D007000100015 ENDBIB 13 0 D007000100016 NOCOMMON 0 0 D007000100017 ENDSUBENT 16 0 D007000199999 SUBENT D0070002 20040217 0000D007000200001 BIB 4 11 D007000200002 REACTION 1(29-CU-65(A,2N)31-GA-67,,SIG) D007000200003 2(29-CU-65(A,2N)31-GA-67,,SIG) D007000200004 ANALYSIS 1Experiment 1. Mean value for 10 targets of different D007000200005 weight. D007000200006 2Experiment 2. Mean value for 10 targets of different D007000200007 weight. D007000200008 SAMPLE Copper targets were prepared frompure copper (99.9%) D007000200009 foil supplied by the Royal Mint Refinery. A 2.135 cm D007000200010 diameter (nomilally 13/16") punch was used to punch D007000200011 out foils which were 4.9 mg/cm2 thick. D007000200012 DETECTOR (GELI) 15 cm3 Ge(Li) detector D007000200013 ENDBIB 11 0 D007000200014 COMMON 1 3 D007000200015 EN D007000200016 MEV D007000200017 26.3 D007000200018 ENDCOMMON 3 0 D007000200019 DATA 4 1 D007000200020 DATA 1DATA-ERR 1DATA 2DATA-ERR 2 D007000200021 MB MB MB MB D007000200022 775.98 16.5 791.98 15.44 D007000200023 ENDDATA 3 0 D007000200024 ENDSUBENT 23 0 D007000299999 SUBENT D0070003 20040217 0000D007000300001 BIB 3 7 D007000300002 REACTION (13-AL-27(D,P+A)11-NA-24,,SIG) D007000300003 SAMPLE The aluminium was supplied by BACO Aluminium Foils Ltd.D007000300004 as 99.99% pure, and was rolled to an average density ofD007000300005 7.25 mg/cm2. Each target was punched to the same area D007000300006 (3.467 cm2) weighted, and then sandwiched between D007000300007 similar aluminium foils. D007000300008 DETECTOR (NAICR) A calibrated 7.6 x 7.6 cm NaI(Tl) detector D007000300009 ENDBIB 7 0 D007000300010 NOCOMMON 0 0 3 D007000300011 DATA 3 10 D007000300012 EN DATA DATA-ERR D007000300013 MEV MB MB D007000300014 12.90 4.859 0.111 D007000300015 13.17 5.928 0.136 D007000300016 13.45 7.330 0.169 D007000300017 13.71 9.083 0.209 D007000300018 14.00 10.90 0.25 D007000300019 14.25 12.00 0.28 D007000300020 14.52 14.21 0.33 D007000300021 14.78 16.08 0.37 D007000300022 15.03 18.07 0.42 D007000300023 15.27 19.63 0.45 D007000300024 ENDDATA 12 0 D007000300025 ENDSUBENT 24 0 D007000399999 ENDENTRY 3 0 D007099999999