ENTRY C2692 20211108 C211C269200000001 SUBENT C2692001 20211108 C211C269200100001 BIB 10 20 C269200100002 TITLE Measurement of the 160Gd(p,n)160Tb excitation C269200100003 function from 4-18 MeV using stacked-target activation C269200100004 AUTHOR (R.K.Chapman,A.S.Voyles,N.Gharibyan,L.A.Bernstein, C269200100005 J.E.Bevins) C269200100006 INSTITUTE (1USAAFT,1USAUCX,1USALRL,1USABRK) C269200100007 REFERENCE (J,ARI,171,109647,2021) C269200100008 FACILITY (CYCLO,1USABRK) Measurement performed at Lawrence C269200100009 Berkeley National Laboratory's 88-Inch Cyclotron C269200100010 SAMPLE Stacked target intersparsed with natural Gd foils C269200100011 and Cu and Ti monitor foils. Target consisted of C269200100012 14 Gd foils with thickness between 9 and 12 mu-m C269200100013 9 Cu foils with thickness between 27 and 11 mu-m C269200100014 8 Ti foils with thickness between of 26 mu-m C269200100015 DETECTOR (HPGE) Ortec GEM-F8250P4 High-Purity Germanium detectorC269200100016 METHOD (ACTIV) C269200100017 ANALYSIS The mean incident energy on each foil is reported as C269200100018 a flux-weighted average differential proton flux C269200100019 obtained from MCNP modeling. The cross section was C269200100020 obtained from the EOB activity C269200100021 HISTORY (20211108C) Compiled by S.H. C269200100022 ENDBIB 20 0 C269200100023 NOCOMMON 0 0 C269200100024 ENDSUBENT 23 0 C269200199999 SUBENT C2692002 20211108 C211C269200200001 BIB 4 19 C269200200002 REACTION (64-GD-160(P,N)65-TB-160,,SIG) C269200200003 DECAY-DATA (65-TB-160,72.3D,DG,298.5783,0.261, C269200200004 DG,879.378,0.301, C269200200005 DG,966.166,0.251, C269200200006 DG,1177.954,0.149) C269200200007 ERR-ANALYS (DATA-ERR) Total uncertainty is a one-sigma C269200200008 uncertainty resulting from the systematic and C269200200009 statistical error propagation including C269200200010 - uncertainty in the mass, length, and width C269200200011 measurements of each foil C269200200012 - uncertainty in irradiation time C269200200013 - uncertainty in decay constant C269200200014 - uncertainty in beam current for each Gd compartment C269200200015 - uncertainty in detection efficiency C269200200016 - uncertainty in detected counts C269200200017 - uncertainty in in the time between the end of C269200200018 irradiation and the beginning of counting C269200200019 - uncertainty in the counting time (0.5 sec) C269200200020 STATUS (TABLE) Data taken from tab.3 of the reference C269200200021 ENDBIB 19 0 C269200200022 NOCOMMON 0 0 C269200200023 DATA 4 15 C269200200024 EN EN-RSL DATA DATA-ERR C269200200025 MEV MEV MB MB C269200200026 17.07 0.28 33.1 1.0 C269200200027 16.11 0.30 33.4 1.0 C269200200028 15.06 0.32 37.4 1.1 C269200200029 14.44 0.34 36.6 1.2 C269200200030 13.55 0.36 41.2 1.2 C269200200031 12.84 0.37 44.4 1.3 C269200200032 12.18 0.40 48.9 1.4 C269200200033 11.41 0.42 56.7 1.8 C269200200034 10.72 0.44 67.5 2.0 C269200200035 9.87 0.47 82.7 2.4 C269200200036 9.10 0.50 95.7 2.8 C269200200037 8.15 0.55 104.8 3.0 C269200200038 7.26 0.60 81.8 2.8 C269200200039 6.16 0.68 32.1 1.0 C269200200040 5.01 0.78 9.8 0.3 C269200200041 ENDDATA 17 0 C269200200042 ENDSUBENT 41 0 C269200299999 ENDENTRY 2 0 C269299999999