ENTRY C2629 20210609 C207C262900000001 SUBENT C2629001 20210609 C207C262900100001 BIB 10 44 C262900100002 TITLE Proton capture on 34S in the astrophysical energy C262900100003 regime of O-Ne novae C262900100004 AUTHOR (M.Lovely,A.Lennarz,D.Connolly,M.Williams,M.Alcorta, C262900100005 A.A.Chen,B.Davids,N.E.Esker,C.Fry,S.A.Gillespie,R.Giri,C262900100006 U.Greife,A.Hussein, D.Hutcheon,J.Karpesky,L.Kroll, C262900100007 J.Liang,P.D.O'Malley,S.Paneru,A.Psaltis,C.Ruiz, C262900100008 A.C.Shotter) C262900100009 INSTITUTE (1USACSM,1CANTMF,1USALAS,2UK YRK,1CANMCM,1USAMSU, C262900100010 1USAOHO,1USANOT,2UK EDG) C262900100011 (1CANCAN) University of Northern British Columbia, C262900100012 Prince George,British Columbia C262900100013 REFERENCE (J,PR/C,103,055801,2021) C262900100014 FACILITY (LINAC,1CANTMF) Experiment performed at ISAC facility C262900100015 at TRIUMF using DRAGON separator. C262900100016 SAMPLE Differentially pumped windowless gas target with C262900100017 effective length of 12.3 cm filled with H2 at the C262900100018 pressure of 5.76+-0.14 torr. Incoming beam with energy C262900100019 of 518.6 keV/A entered the gass target.Outgoing energy C262900100020 was measured to be 499.6 keV/A. C262900100021 DETECTOR (MAGSP) Recoil ions were momentum analysed in DRAGON C262900100022 two stage electromagnetic separator, each consisting C262900100023 of with one magnetic and one electrostatic dipole. C262900100024 Only one charge state can be transported through the C262900100025 length of DRAGON separator. Ions are identified in C262900100026 focal plane detector of the spectrometer, which consistC262900100027 of several detectors. C262900100028 (BGO) Prompt and de-excitation gamma-rays emitted C262900100029 from the gas target were detected using array of 30 C262900100030 closely packed BGO hexagonal crystals with solid C262900100031 angle coverage of 90% from the center of the target. C262900100032 (MCPLT) Ion velocity was measured using two C262900100033 micro-channel plate detectors separated by 57 cm. C262900100034 (TELES,SISD,IOCH) For ion identification a hybrid C262900100035 telescope detector consisting of a double sided C262900100036 silicon strip detector and ionization chamber C262900100037 METHOD (TOF,EDE) Inverse kinematics was used in the C262900100038 experiment. For identification of recoil ions, time C262900100039 of flight (TOF) as well as dE-E method was used. C262900100040 Local TOF of focal plane detector as well as C26C262900100041 between BGO detector and focal plane detector were C262900100042 used for ion identification C262900100043 INC-SOURCE Heavy ion beam of 34S was produced by the DRAGON C262900100044 off-line ion source. C262900100045 HISTORY (20210609C) Compiled by S.H. C262900100046 ENDBIB 44 0 C262900100047 NOCOMMON 0 0 C262900100048 ENDSUBENT 47 0 C262900199999 SUBENT C2629002 20210609 C207C262900200001 BIB 3 15 C262900200002 REACTION (1-H-1(16-S-34,G),,WID/STR) C262900200003 ERR-ANALYS (ERR-1) Systematic uncertainty in BGO efficiency C262900200004 (ERR-2) Uncertainty in charge state fraction C262900200005 (ERR-3) Uncertainty in target transmission C262900200006 (ERR-4) Uncertainty in live time correction C262900200007 (ERR-5) Uncertainty in separator transmission C262900200008 (ERR-6) Uncertainty in MCP grid transmission C262900200009 (ERR-7) Uncertainty in hybrid efficiency C262900200010 (ERR-8) Uncertainty in target pressure C262900200011 (ERR-9) Uncertainty in target temperature C262900200012 (ERR-10) Uncertainty in stopping power C262900200013 (ERR-11) Uncertainty in integrated beam particles C262900200014 (ERR-12) Uncertainty in recoils detected C262900200015 (ERR-T) Total uncertainty C262900200016 STATUS (TABLE) Data taken from tab. 4 of the reference C262900200017 ENDBIB 15 0 C262900200018 COMMON 12 6 C262900200019 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 C262900200020 ERR-7 ERR-8 ERR-9 ERR-10 ERR-11 ERR-12 C262900200021 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900200022 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900200023 10.1 5.5 1.9 0.9 0.1 1.2 C262900200024 0.8 2.6 0.8 10.6 1.9 0.7 C262900200025 ENDCOMMON 6 0 C262900200026 DATA 4 1 C262900200027 EN-RES-CM EN-RES-ERR DATA ERR-T C262900200028 EV EV EV EV C262900200029 495.5 0.6 1.37E-2 0.22E-2 C262900200030 ENDDATA 3 0 C262900200031 ENDSUBENT 30 0 C262900299999 SUBENT C2629003 20210609 C207C262900300001 BIB 3 15 C262900300002 REACTION (1-H-1(16-S-34,G),,WID/STR) C262900300003 ERR-ANALYS (ERR-1) Systematic uncertainty in BGO efficiency C262900300004 (ERR-2) Uncertainty in charge state fraction C262900300005 (ERR-3) Uncertainty in target transmission C262900300006 (ERR-4) Uncertainty in live time correction C262900300007 (ERR-5) Uncertainty in separator transmission C262900300008 (ERR-6) Uncertainty in MCP grid transmission C262900300009 (ERR-7) Uncertainty in hybrid efficiency C262900300010 (ERR-8) Uncertainty in target pressure C262900300011 (ERR-9) Uncertainty in target temperature C262900300012 (ERR-10) Uncertainty in stopping power C262900300013 (ERR-11) Uncertainty in integrated beam particles C262900300014 (ERR-12) Uncertainty in recoils detected C262900300015 (ERR-T) Total uncertainty C262900300016 STATUS (TABLE) Data taken from tab. 4 of the reference C262900300017 ENDBIB 15 0 C262900300018 COMMON 12 6 C262900300019 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 C262900300020 ERR-7 ERR-8 ERR-9 ERR-10 ERR-11 ERR-12 C262900300021 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900300022 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900300023 17.6 10.3 1.8 3.1 0.1 1.2 C262900300024 6.2 1.0 0.8 10.1 2.4 20.0 C262900300025 ENDCOMMON 6 0 C262900300026 DATA 4 1 C262900300027 EN-RES-CM EN-RES-ERR DATA ERR-T C262900300028 EV EV EV EV C262900300029 471. 2. 9.4E-5 2.9E-5 C262900300030 ENDDATA 3 0 C262900300031 ENDSUBENT 30 0 C262900399999 SUBENT C2629004 20210609 C207C262900400001 BIB 3 15 C262900400002 REACTION (1-H-1(16-S-34,G),,WID/STR) C262900400003 ERR-ANALYS (ERR-1) Systematic uncertainty in BGO efficiency C262900400004 (ERR-2) Uncertainty in charge state fraction C262900400005 (ERR-3) Uncertainty in target transmission C262900400006 (ERR-4) Uncertainty in live time correction C262900400007 (ERR-5) Uncertainty in separator transmission C262900400008 (ERR-6) Uncertainty in MCP grid transmission C262900400009 (ERR-7) Uncertainty in hybrid efficiency C262900400010 (ERR-8) Uncertainty in target pressure C262900400011 (ERR-9) Uncertainty in target temperature C262900400012 (ERR-10) Uncertainty in stopping power C262900400013 (ERR-11) Uncertainty in integrated beam particles C262900400014 (ERR-12) Uncertainty in recoils detected C262900400015 (ERR-T) Total uncertainty C262900400016 STATUS (TABLE) Data taken from tab. 4 of the reference C262900400017 ENDBIB 15 0 C262900400018 COMMON 12 6 C262900400019 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 C262900400020 ERR-7 ERR-8 ERR-9 ERR-10 ERR-11 ERR-12 C262900400021 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900400022 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900400023 18.1 3.9 1.4 0.5 0.1 1.2 C262900400024 4.6 1.1 0.8 10.6 5.8 6.8 C262900400025 ENDCOMMON 6 0 C262900400026 DATA 4 1 C262900400027 EN-RES-CM EN-RES-ERR DATA ERR-T C262900400028 EV EV EV EV C262900400029 407. 2. 8.0E-4 1.9E-4 C262900400030 ENDDATA 3 0 C262900400031 ENDSUBENT 30 0 C262900499999 SUBENT C2629005 20210609 C207C262900500001 BIB 3 15 C262900500002 REACTION (1-H-1(16-S-34,G),,WID/STR) C262900500003 ERR-ANALYS (ERR-1) Systematic uncertainty in BGO efficiency C262900500004 (ERR-2) Uncertainty in charge state fraction C262900500005 (ERR-3) Uncertainty in target transmission C262900500006 (ERR-4) Uncertainty in live time correction C262900500007 (ERR-5) Uncertainty in separator transmission C262900500008 (ERR-6) Uncertainty in MCP grid transmission C262900500009 (ERR-7) Uncertainty in hybrid efficiency C262900500010 (ERR-8) Uncertainty in target pressure C262900500011 (ERR-9) Uncertainty in target temperature C262900500012 (ERR-10) Uncertainty in stopping power C262900500013 (ERR-11) Uncertainty in integrated beam particles C262900500014 (ERR-12) Uncertainty in recoils detected C262900500015 (ERR-T) Total uncertainty C262900500016 STATUS (TABLE) Data taken from tab. 4 of the reference C262900500017 ENDBIB 15 0 C262900500018 COMMON 12 6 C262900500019 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 C262900500020 ERR-7 ERR-8 ERR-9 ERR-10 ERR-11 ERR-12 C262900500021 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900500022 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C262900500023 17.3 9.8 3.0 0.9 0.1 1.2 C262900500024 0.7 1.0 0.8 8.2 7.8 18.8 C262900500025 ENDCOMMON 6 0 C262900500026 DATA 4 1 C262900500027 EN-RES-CM EN-RES-ERR DATA ERR-T C262900500028 EV EV EV EV C262900500029 272. 2. 1.22E-5 0.36E-5 C262900500030 ENDDATA 3 0 C262900500031 ENDSUBENT 30 0 C262900599999 SUBENT C2629006 20210609 C207C262900600001 BIB 2 2 C262900600002 REACTION (1-H-1(16-S-34,G),,WID/STR) C262900600003 STATUS (TABLE) Data taken from tab. 4 of the reference C262900600004 ENDBIB 2 0 C262900600005 NOCOMMON 0 0 C262900600006 DATA 3 4 C262900600007 EN-RES-CM EN-RES-ERR DATA-MAX C262900600008 EV EV EV C262900600009 452. 2. 3.1E-5 C262900600010 431. 4. 3.9E-5 C262900600011 390. 2. 6.9E-6 C262900600012 303. 2. 7.2E-6 C262900600013 ENDDATA 6 0 C262900600014 ENDSUBENT 13 0 C262900699999 ENDENTRY 6 0 C262999999999