ENTRY C2627 20210610 C207C262700000001 SUBENT C2627001 20210610 C207C262700100001 BIB 10 39 C262700100002 TITLE Elastic scattering measurements for the 10C+208Pb C262700100003 system at Elab = 66 MeV C262700100004 AUTHOR (R.Linares,Mandira Sinha,E.N.Cardozo,V.Guimaraes, C262700100005 G.V.Rogachev,J.Hooker,E.Koshchiy,T.Ahn,C.Hunt, C262700100006 H.Jayatissa,S.Upadhyayula,B.Roeder,A.Saastomoinen, C262700100007 J.Lubian,M.Rodriguez-Gallardo,J.Casal,K.C.C.Pires, C262700100008 M.Assuncao,Y.Penionzhkevich,S.Lukyanov) C262700100009 INSTITUTE (3BZLUFF,3INDBOS,3BZLUSP,1USATAM,2SPNSEU,2ITYUPV, C262700100010 4ZZZDUB) C262700100011 (3BZLBZL) Federal University of Sao Paulo,Diadema C262700100012 REFERENCE (J,PR/C,103,044613,2021) C262700100013 FACILITY (CYCLO,1USATAM) Experiment performed using K500 C262700100014 superconducting cyclotron and MARS Spectrometer at C262700100015 the Cyclotron Institute of Texas A+M University C262700100016 SAMPLE (82-PB-208,ENR=0.95) Two isotopically enriched 208Pb C262700100017 foils with thickness of 2.37 mg/cm2, evaporated on a C262700100018 0.08 mg/cm2 thick carbon backing C262700100019 DETECTOR (TELES,SISD,SISD) Charged particles were detected C262700100020 using telescope consisting of two double-sided C262700100021 silicon strip detectors (DSSSD) was placed at forward C262700100022 angle. E detectcor was 128 x 128 DSSSD with active C262700100023 area of 97.2 x 97.2 mm2 and thickness of 500 mu-m. dE C262700100024 detector was 16 x 16 DSSSD with active area of 49.5 x C262700100025 49.5 mm2 and thickness of 38 mu-m. E and dE detectors C262700100026 were placed 100 mm and 50 mm away from target, C262700100027 respectivelly and covered laboratory theta angles C262700100028 between 15 deg and 89 deg. C262700100029 (SISD) Another identical DSSSD E detector was placed C262700100030 at a distance 100 mm from the target at backward C262700100031 angle, covering theta laboratoty angles between 87 C262700100032 deg and 161 deg. C262700100033 METHOD (EDE) C262700100034 INC-SOURCE The radioactive 10C beam was produced by the charge- C262700100035 exchange p(10B,10C)n reaction. The primary 10B beam C262700100036 with energy of 9.6MeV/u was delivered by the K500 C262700100037 superconducting cyclotron and impinged on a cooled H2 C262700100038 gas cell. The produced 10C ions were selected by the C262700100039 Momentum Achromatic Recoil Spectrometer. C262700100040 HISTORY (20210610C) Compiled by S.H. C262700100041 ENDBIB 39 0 C262700100042 NOCOMMON 0 0 C262700100043 ENDSUBENT 42 0 C262700199999 SUBENT C2627002 20210610 C207C262700200001 BIB 3 6 C262700200002 REACTION (82-PB-208(6-C-10,EL)82-PB-208,,DA,,RTH) C262700200003 ERR-ANALYS (ERR-S) Statistical uncertainty C262700200004 (ERR-SYS) Systematic uncertainties mainly due to solid C262700200005 angles and the beam spot size at the target C262700200006 STATUS (TABLE) Data presented in fig. 4 of the reference C262700200007 sent by author C262700200008 ENDBIB 6 0 C262700200009 COMMON 2 3 C262700200010 EN ERR-SYS C262700200011 MEV PER-CENT C262700200012 66.0 10. C262700200013 ENDCOMMON 3 0 C262700200014 DATA 4 20 C262700200015 ANG-CM ANG-ERR DATA ERR-S C262700200016 ADEG ADEG NO-DIM NO-DIM C262700200017 34. 1.5 1.03 0.01 C262700200018 39.2 2.5 0.94 0.01 C262700200019 44.3 2.5 0.99 0.01 C262700200020 49.5 2.5 1. 0.01 C262700200021 54.6 2.5 1.04 0.01 C262700200022 59.8 2.5 1.03 0.02 C262700200023 64.9 2.5 1. 0.02 C262700200024 70. 2.5 1.02 0.03 C262700200025 75. 2.5 0.96 0.03 C262700200026 80.1 2.5 0.87 0.04 C262700200027 85.1 2.5 0.64 0.05 C262700200028 105.04 2.5 0.36 0.03 C262700200029 109.97 2.5 0.31 0.02 C262700200030 114.88 2.5 0.36 0.03 C262700200031 119.78 2.5 0.31 0.02 C262700200032 124.66 2.5 0.28 0.03 C262700200033 129.53 2.5 0.26 0.03 C262700200034 134.38 2.5 0.21 0.03 C262700200035 139.22 2.5 0.13 0.03 C262700200036 146.45 5. 0.09 0.04 C262700200037 ENDDATA 22 0 C262700200038 ENDSUBENT 37 0 C262700299999 ENDENTRY 2 0 C262799999999