ENTRY C2592 20210127 C202C259200000001 SUBENT C2592001 20210127 C202C259200100001 BIB 9 33 C259200100002 TITLE Beyond the acceptance limit of DRAGON: The case of C259200100003 the 6Li(alpha,gamma)10B reaction C259200100004 AUTHOR (A.Psaltis,A.A.Chen,D.S.Connolly,B.Davids,G.Gilardy, C259200100005 R.Giri,U.Greife,W.Huang,D.A.Hutcheon,J.Karpesky, C259200100006 A.Lennarz,J.Liang,M.Lovely,S.N.Paneru,C.Ruiz, C259200100007 G.Tenkila,M.Williams) C259200100008 INSTITUTE (1CANMCM,1CANTMF,1USANOT,2FR GRA,1USACSM,1CANUBC, C259200100009 1USAOHO,2UK YRK) C259200100010 (1CANCAN) University of Northern British Columbia, C259200100011 Prince George C259200100012 REFERENCE (J,NIM/A,987,164828,2021) C259200100013 FACILITY (LINAC,1CANTMF) Experiment performed at DRAGON C259200100014 facility using off-line ion source, ISAC-1 C259200100015 radio-frequency quadrupole and drift-tube linac C259200100016 SAMPLE Windowless He gas target at the pressure of 5.0+-0.1 C259200100017 torr and thickness of (1.97+-0.04)E+018 atoms/cm2. C259200100018 DETECTOR (MAGSP) DRAGON magnetic spectrometer was used to C259200100019 momentum analyze 10Be recoil products C259200100020 (SISD) Gridded double-sided Si strip detector with C259200100021 thickness of 66 mu-m was placed near the focal plane C259200100022 of the DRAGON spectrometer to detect and identify C259200100023 reaction recoils. C259200100024 (BGO) Gamma rays are detected by an array of 30 BGO C259200100025 detectors covering almost whole solid angle around C259200100026 the gas target C259200100027 METHOD Inverse kinematics was used C259200100028 (COINC) Coincidence between BGO array and Si strip C259200100029 detector was required. C259200100030 (TOF) Time of flight of 10B recoil, measured as time C259200100031 difference between detected gamma ray in BGO and recoilC259200100032 detected in Si strip detector, was used in recoil C259200100033 identification C259200100034 HISTORY (20210127C) Compiled by S.H. C259200100035 ENDBIB 33 0 C259200100036 NOCOMMON 0 0 C259200100037 ENDSUBENT 36 0 C259200199999 SUBENT C2592002 20210127 C202C259200200001 BIB 3 10 C259200200002 REACTION (3-LI-6(A,G),,WID/STR) C259200200003 ERR-ANALYS (ERR-S) Statistical uncertainty C259200200004 (ERR-SYS) Systematic uncertainty (total) C259200200005 (ERR-1) Uncertainty in charge state fraction C259200200006 (ERR-2) Uncertainty in beam intensity C259200200007 (ERR-3) Uncertainty in BGO detection efficiency C259200200008 (ERR-4) Uncertainty in separator efficiency C259200200009 (ERR-5) Uncertaainty in target stopping power C259200200010 (ERR-6) Uncertainty in DAQ livetime C259200200011 STATUS (TABLE) Data taken from text p.6 of the reference C259200200012 ENDBIB 10 0 C259200200013 COMMON 6 3 C259200200014 ERR-1 ERR-2 ERR-3 ERR-4 ERR-5 ERR-6 C259200200015 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C259200200016 1.5 1.64 11.4 4.1 5.5 0.009 C259200200017 ENDCOMMON 3 0 C259200200018 DATA 6 1 C259200200019 EN-RES EN-ERR DATA +ERR-S -ERR-S ERR-SYS C259200200020 KEV MEV EV EV EV EV C259200200021 1466.6 0.006 0.225 0.025 0.035 0.030 C259200200022 ENDDATA 3 0 C259200200023 ENDSUBENT 22 0 C259200299999 ENDENTRY 2 0 C259299999999