ENTRY C2462 20200323 C195C246200000001 SUBENT C2462001 20200323 C195C246200100001 BIB 11 39 C246200100002 TITLE Single-particle shell strengths near the doubly magic C246200100003 nucleus 56Ni and the 56Ni(p,g)57Cu reaction rate in C246200100004 explosive astrophysical burning C246200100005 AUTHOR (D.Kahl,P.J.Woods,T.Poxon-Pearson,F.M.Nunes,B.A.Brown, C246200100006 H.Schatz,T.Baumann,D.Bazin,J.A.Belarge,P.C.Bender, C246200100007 B.Elman,A.Estrade,A.Gade,A.Kankainen,C.Lederer-Woods, C246200100008 S.Lipschutz,B.Longfellow,S.-J.Lonsdale,E.Lunderberg, C246200100009 F.Montes,W.J.Ong,G.Perdikakis,J.Pereira,C.Sullivan, C246200100010 R.Taverner,D.Weisshaar,R.Zegers) C246200100011 INSTITUTE (2UK EDG,1USAMSU,2SF JYV) C246200100012 (1USAUSA) Central Michigan University, Mount Pleasant C246200100013 REFERENCE (J,PL/B,797,134803,2019) C246200100014 FACILITY (CYCTM,1USAMSU) Experiment performed at the tandem C246200100015 cyclotron system at the National Superconducting C246200100016 Cyclotron Laboratory, East Lansing C246200100017 SAMPLE Deuterated polyethylene target (CD2)n with thickness C246200100018 of (10.7+-0.8)mg/cm2. C246200100019 DETECTOR (MAGSP) Beam-like residues were collected and C246200100020 analyzed with the S800 spectro-graph positioned at C246200100021 0deg scattering angle. C246200100022 (HPGE) Gamma rays were detected by high resolution C246200100023 gamma ray array GRETINA (Gamma-Ray Energy Tracking C246200100024 In-beam Nuclear Array).GRETINA detectors were C246200100025 positioned in two rings at laboratory angles of 58deg C246200100026 and 90deg with respect to the beam direction. C246200100027 METHOD (COINC) Coincidence between gammma rays from reaction C246200100028 products detected in GRETINA and reaction residue C246200100029 identified in S800 spectrograph was required C246200100030 (GSPEC) Level properties were determined with the help C246200100031 of gamma spetrometry C246200100032 Inverse kinematics was used. C246200100033 INC-SOURCE Radioactive beam of 56Ni ions was produced by C246200100034 in-flight fragmentation of primary 58Ni beam with C246200100035 energy of 160MeV/A on 9Be production target. 56Ni C246200100036 ions were separated using A1900 fragment separator. C246200100037 The 56Ni beam had purity of 47% and average intensity C246200100038 of 3E+5 particles per sec. C246200100039 ERR-ANALYS (DATA-ERR) Origin of uncertainties not described C246200100040 HISTORY (20200323C) Compiled by S.H. C246200100041 ENDBIB 39 0 C246200100042 COMMON 1 3 C246200100043 EN C246200100044 MEV/A C246200100045 33.6 C246200100046 ENDCOMMON 3 0 C246200100047 ENDSUBENT 46 0 C246200199999 SUBENT C2462002 20200323 C195C246200200001 BIB 2 3 C246200200002 REACTION ((1-H-2(28-NI-56,N)29-CU-57,PAR,SIG)= C246200200003 (28-NI-56(D,N)29-CU-57,PAR,SIG)) C246200200004 STATUS (TABLE) Data taken from tab.1 of the reference C246200200005 ENDBIB 3 0 C246200200006 NOCOMMON 0 0 C246200200007 DATA 4 4 C246200200008 E-LVL DATA DATA-ERR DATA-MAX C246200200009 MEV MB MB MB C246200200010 1.028 2.00 0.40 C246200200011 1.109 0.28 0.06 C246200200012 2.398 0.2 C246200200013 2.525 0.2 C246200200014 ENDDATA 6 0 C246200200015 ENDSUBENT 14 0 C246200299999 SUBENT C2462003 20200323 C195C246200300001 BIB 2 3 C246200300002 REACTION ((1-H-2(28-NI-56,P)28-NI-57,PAR,SIG)= C246200300003 (28-NI-56(D,P)28-NI-57,PAR,SIG)) C246200300004 STATUS (TABLE) Data taken from tab.1 of the reference C246200300005 ENDBIB 3 0 C246200300006 NOCOMMON 0 0 C246200300007 DATA 4 4 C246200300008 E-LVL DATA DATA-ERR DATA-MAX C246200300009 MEV MB MB MB C246200300010 0.768 2.10 0.60 C246200300011 1.122 0.50 0.15 C246200300012 2.443 0.4 C246200300013 2.579 1.24 0.36 C246200300014 ENDDATA 6 0 C246200300015 ENDSUBENT 14 0 C246200399999 ENDENTRY 3 0 C246299999999