ENTRY C2441 20191105 C188C244100000001 SUBENT C2441001 20191105 C188C244100100001 BIB 9 28 C244100100002 TITLE Direct neutron capture cross section on 80Ge and C244100100003 probing shape coexistence in neutron-rich nuclei C244100100004 AUTHOR (S.Ahn,D.W.Bardayan,K.L.Jones,A.S.Adekola,G.Arbanas, C244100100005 J.C.Blackmon,K.Y.Chae,K.A.Chipps,J.A.Cizewski, C244100100006 S.Hardy,M.E.Howard, R.L.Kozub,B.Manning,M.Matos, C244100100007 C.D.Nesaraja,P.D.O'Malley,S.D.Pain,W.A.Peters, C244100100008 S.T.Pittman,B.C.Rasco,M.S.Smith,I.Spassova) C244100100009 INSTITUTE (1USATEN,1USAORL,1USAMSU,1USANOT,1USARUT,1USALSU, C244100100010 1USACSM,1USATTU,1USAOAU) C244100100011 (3KORKOR) Sungkyunkwan University, Suwon C244100100012 REFERENCE (J,PR/C,100,044613,2019) C244100100013 FACILITY (VDGT,1USAORL) Experiment performed at the Holifield C244100100014 Radioactive Ion Beam Facility (HRIBF) at Oak Ridge C244100100015 National Laboratory. C244100100016 SAMPLE Deuterated polyethylene target (CD2)n with thickness C244100100017 of 174 mu-g/cm2 C244100100018 DETECTOR (IOCH) A fast ionization counter was placed C244100100019 downstream of the target chamber to detect and C244100100020 identify the beam components and the 81Ge recoils. C244100100021 (SI) Several silicon detectors, Micron S1 covering C244100100022 theta(lab) =154-170deg, SIDAR covering theta(lab)=124- C244100100023 154deg, MICRON X3 covering theta(lab) = 50- 89deg, C244100100024 two Micron SX3s covering theta(lab) =50-124deg and C244100100025 Micron BB15 covering theta(lab) = 50-124 deg were C244100100026 used to measure energies and angles of light ion C244100100027 ejectiles from (d,d) and (d,p) reactions. C244100100028 METHOD Inverse kinematics was used C244100100029 HISTORY (20191105C) Compiled by S.H. C244100100030 ENDBIB 28 0 C244100100031 NOCOMMON 0 0 C244100100032 ENDSUBENT 31 0 C244100199999 SUBENT C2441002 20191105 C188C244100200001 BIB 4 9 C244100200002 REACTION ((1-H-2(32-GE-80,P)32-GE-81,PAR,DA)= C244100200003 (32-GE-80(D,P)32-GE-81,PAR,DA,RSD)) C244100200004 ERR-ANALYS (ERR-S) Statistical error C244100200005 (ERR-1) Systematic uncertainty in target thickness C244100200006 (ERR-2) Systematic uncertainty due to geometrical C244100200007 parameters in the detector setup, C244100200008 METHOD Inverse kinematics was used C244100200009 STATUS (TABLE) Data presented in fig. 3 of the reference C244100200010 sent by author (S.A.) C244100200011 ENDBIB 9 0 C244100200012 COMMON 5 3 C244100200013 EN E-LVL E-LVL ERR-1 ERR-2 C244100200014 MEV/A KEV KEV PER-CENT PER-CENT C244100200015 3.875 679. 711. 13. 10. C244100200016 ENDCOMMON 3 0 C244100200017 DATA 3 8 C244100200018 ANG-CM DATA-CM ERR-S C244100200019 ADEG MB/SR MB/SR C244100200020 12. 9.35 0.76 C244100200021 15. 7.90 0.76 C244100200022 17. 7.27 0.71 C244100200023 19. 6.60 0.66 C244100200024 21. 6.44 0.96 C244100200025 31. 4.72 0.51 C244100200026 37. 6.29 0.65 C244100200027 45. 3.89 0.42 C244100200028 ENDDATA 10 0 C244100200029 ENDSUBENT 28 0 C244100299999 ENDENTRY 2 0 C244199999999