ENTRY C2409 20190916 C188C240900000001 SUBENT C2409001 20190916 C188C240900100001 BIB 11 38 C240900100002 TITLE Strong coupling effect in the elastic scattering of C240900100003 the 10C+58Ni system near barrier C240900100004 AUTHOR (V.Guimaraes,E.N.Cardozo,V.B.Scarduelli,J.Lubian, C240900100005 J.J.Kolata,P.D.O'Malley,D.W.Bardayan,E.F.Aguilera, C240900100006 E.Martinez-Quiroz,D.Lizcano,A.Garcia-Flores,M.Febbraro,C240900100007 C.C.Lawrence,J.Riggins,R.O.Torres-Isea,P.N.de Faria, C240900100008 D.S.Monteiro,E.S.Rossi Jr,N.N.Deshmukh) C240900100009 INSTITUTE (3BZLUSP,1USANOT,3MEXINI,1USAORL,1USAHRV,1USAMHG, C240900100010 3INDSAH,3BZLUFF) C240900100011 (3BZLBZL) Universidade Federal da Integracao Latino- C240900100012 Americana, Parana C240900100013 REFERENCE (J,PR/C,100,034603,2019) C240900100014 FACILITY (VDGT,1USANOT) Experiment performed using TwinSol C240900100015 facility at the 10MV UND FN-Tandem Accelerator at the C240900100016 Nuclear Science Laboratory of the University of Notre C240900100017 Dame C240900100018 SAMPLE (28-NI-58,ENR=0.99) Enriched Ni foil with thickness C240900100019 of 0.75 mg/cm2. C240900100020 DETECTOR (TELES,SI,SI) Detector setup consisted of 3 telescope C240900100021 detectors with dE and E detector 20 mu-m and 1000 C240900100022 mu-m thick at forward angles and 4 E detectors C240900100023 1000 mu-m thick at backward angles. C240900100024 METHOD (EDE) E-dE method was used for particle identification C240900100025 at forward angles. C240900100026 MONITOR (79-AU-197(6-C-10,EL)79-AU-197,,DA,,RTH) C240900100027 It was assumed, that elastic scattering in this C240900100028 angular range is pure Rutherford scattering. C240900100029 INC-SOURCE (KINDT) The 10C secondary radioactive beam was C240900100030 produced in-flight using 3He(10B,10C) charge- C240900100031 exchange reaction. The 10B(5+) primary beam C240900100032 was accelerated to an energy of 54.0 MeV C240900100033 and had an intensity of typically 200 enA. Primary C240900100034 target was a 3He gas cell with pressure of 0.5 atm, C240900100035 sealed with 2 mu-m thick Ti foils. Two C240900100036 superconducting solenoids of the TwinSol system C240900100037 collected, selected and focused the secondary beam of C240900100038 10C produced in the forward direction. C240900100039 HISTORY (20190916C) Compiled by S.H. C240900100040 ENDBIB 38 0 C240900100041 NOCOMMON 0 0 C240900100042 ENDSUBENT 41 0 C240900199999 SUBENT C2409002 20190916 C188C240900200001 BIB 3 4 C240900200002 REACTION (28-NI-58(6-C-10,EL)28-NI-58,,DA,,RTH) C240900200003 STATUS (CURVE) Data taken from fig. 4 of the reference. C240900200004 Waiting for data from author. C240900200005 ERR-ANALYS (ERR-S) Uncertainties are mainly of statistical origin C240900200006 ENDBIB 4 0 C240900200007 COMMON 1 3 C240900200008 EN C240900200009 MEV C240900200010 35.3 C240900200011 ENDCOMMON 3 0 C240900200012 DATA 3 7 C240900200013 ANG-CM DATA ERR-S C240900200014 ADEG NO-DIM NO-DIM C240900200015 34.9 9.94E-01 C240900200016 52.0 9.08E-01 C240900200017 84.7 5.48E-01 4.71E-02 C240900200018 100.1 3.19E-01 8.06E-02 C240900200019 114.7 2.49E-01 1.11E-01 C240900200020 128.7 2.60E-01 1.50E-01 C240900200021 142.2 1.49E-01 9.96E-02 C240900200022 ENDDATA 9 0 C240900200023 ENDSUBENT 22 0 C240900299999 ENDENTRY 2 0 C240999999999