ENTRY C2217 20211008 C210C221700000001 SUBENT C2217001 20211008 C210C221700100001 BIB 9 39 C221700100002 TITLE Investigation of the role of 10Li resonances in the C221700100003 halo structure of 11Li through the 11Li(p,d)10Li C221700100004 transfer reaction C221700100005 AUTHOR (A.Sanetullaev,R.Kanungo,J.Tanaka,M.Alcorta,C.Andreoiu,C221700100006 P.Bender,A.A.Chen,G.Christian,B.Davids,J.Fallis, C221700100007 J.P.Fortin,N.Galinski,A.T.Gallant,P.E.Garrett, C221700100008 G.Hackman,B.Hadinia,S.Ishimoto,M.Keefe,R.Krucken, C221700100009 J.Lighthall,E.McNeice,D.Miller,J.Purcell,J.S.Randhawa, C221700100010 T.Roger,A.Rojas,H.Savajols,A.Shotter,I.Tanihata, C221700100011 I.J.Thompsonm,C.Unsworth,P.Voss,Z.Wang) C221700100012 INSTITUTE (1CANSMR,1CANTMF,2JPNOSA,1CANSFU,1CANMCM,1CANLUQ, C221700100013 1CANGUE,2JPNKEK,1CANUBC,2FR GAN,2UK EDG,3CPRBHN, C221700100014 1USALRL) C221700100015 REFERENCE (J,PL/B,755,481,2016) C221700100016 FACILITY (LINAC,1CANTMF) Experiment performed using C221700100017 superconducting linac at the ISACII facility at TRIUMF C221700100018 SAMPLE Solid H2 target formed by spraying H2 gas onto a 5.4 C221700100019 mu-m thick cooled Ag foil. The foil adheres to a C221700100020 copper target cell frame cooled to 4K. The average C221700100021 thickness was approx. 60 mu-m varying from 30 mu-m to C221700100022 130 mu-m with time. The target thickness was C221700100023 continuously measured using the Ag(11Li,11Li)Ag C221700100024 elastic scattering peak energy of 11Li. C221700100025 DETECTOR (TELES,SISD,CSICR) The light particles p,d,t were C221700100026 detected using annular arrays of segmented silicon C221700100027 strip detectors backed by a CsI(Tl) array. The C221700100028 silicon detectors with thickness of 100 mu-m served C221700100029 as dE detector, the total energy was measured using C221700100030 CsI(Tl) array. This array covered laboratory angles C221700100031 of theta(lab) from 32 deg to 58 deg. C221700100032 (TELES,SISD,SISD) The heavy reaction residues pass C221700100033 through the hole in the YY1 annular array, and are C221700100034 detected using a dE - E (60 mu-m and 500 mu-m thick) C221700100035 double-sided segmented silicon strip detector array C221700100036 placed further downstream of the target. This C221700100037 telescope covered laboratory angles of theta(lab) C221700100038 from 1.8 deg to 5.7 deg. C221700100039 METHOD (EDE,COINC) C221700100040 HISTORY (20210818C) Compiled by S.H. C221700100041 ENDBIB 39 0 C221700100042 NOCOMMON 0 0 C221700100043 ENDSUBENT 42 0 C221700199999 SUBENT C2217002 20211008 C210C221700200001 BIB 4 11 C221700200002 REACTION (3-LI-11(P,EL)3-LI-11,,DA) C221700200003 ERR-ANALYS (ERR-1) Systematic uncertainty in target thickness C221700200004 (ERR-2) Systematic uncertainty from solid angle C221700200005 efficiency estimation C221700200006 (ERR-T) Total uncertainty include statistical and C221700200007 systematic uncertainties C221700200008 METHOD (EDE,COINC) Coincidence between scattered protons in C221700200009 Si-Cs array and recoil Li ions in Si-Si telescope was C221700200010 required. C221700200011 STATUS (CURVE) Data taken from fig.3 of the reference. C221700200012 Waiting for data from author. C221700200013 ENDBIB 11 0 C221700200014 COMMON 3 3 C221700200015 EN ERR-1 ERR-2 C221700200016 MEV/A PER-CENT PER-CENT C221700200017 5.7 5. 5. C221700200018 ENDCOMMON 3 0 C221700200019 DATA 3 13 C221700200020 ANG-CM DATA-CM ERR-T C221700200021 ADEG MB/SR MB/SR C221700200022 70.1 1.23 0.28 C221700200023 72.8 1.62 0.34 C221700200024 75.1 2.09 0.36 C221700200025 78.3 2.09 0.33 C221700200026 81.1 2.61 0.35 C221700200027 84.7 2.83 0.36 C221700200028 88.3 3.39 0.37 C221700200029 91.9 3.77 0.40 C221700200030 95.8 3.58 0.38 C221700200031 100.0 3.68 0.36 C221700200032 104.3 3.58 0.33 C221700200033 109.0 3.70 0.34 C221700200034 114.2 3.59 0.34 C221700200035 ENDDATA 15 0 C221700200036 ENDSUBENT 35 0 C221700299999 SUBENT C2217003 20211008 C210C221700300001 BIB 4 6 C221700300002 REACTION (3-LI-11(P,D)3-LI-10,PAR,DA) C221700300003 EN-SEC (E-RL,N+LI9) Relative energy between neutron and C221700300004 Li-9 in Li-10 C221700300005 ERR-ANALYS (DATA-ERR) Origin of uncertainties not described C221700300006 STATUS (CURVE) Data taken from fig.4 of the reference. C221700300007 Waiting for data from author. C221700300008 ENDBIB 6 0 C221700300009 COMMON 2 3 C221700300010 EN E-RL C221700300011 MEV/A MEV C221700300012 5.7 0.62 C221700300013 ENDCOMMON 3 0 C221700300014 DATA 3 7 C221700300015 ANG-CM DATA-CM DATA-ERR C221700300016 ADEG MB/SR MB/SR C221700300017 19.6 32.20 7.10 C221700300018 29.6 22.59 5.49 C221700300019 39.6 11.30 3.21 C221700300020 64.9 3.82 0.74 C221700300021 74.8 2.69 0.48 C221700300022 84.9 1.79 0.33 C221700300023 94.9 1.38 0.33 C221700300024 ENDDATA 9 0 C221700300025 ENDSUBENT 24 0 C221700399999 ENDENTRY 3 0 C221799999999