ENTRY            C2154   20241031                                 C215400000001 
SUBENT        C2154001   20241031   20250110                      C215400100001 
BIB                 11         24                                 C215400100002 
TITLE      Ac, La, and Ce radioimpurities in 225Ac produced in    C215400100003 
           40 - 200 MeV proton irradiations of thorium            C215400100004 
AUTHOR     (J.W.Engle,J.W.Weidner,B.D.Ballard,M.E.Fassbender,     C215400100005 
           L.A.Hudston,K.R.Jackman,D.E.Dry,L.E.Wolfsberg,         C215400100006 
           L.J.Bitteker,J.L.Ullmann,M.S.Gulley,Ch.Pillai,G.Goff,  C215400100007 
           E.R.Birnbaum,K.D.John,S.G.Mashnik,F.M.Nortier)         C215400100008 
INSTITUTE  (1USALAS,1USAAFT)                                      C215400100009 
REFERENCE  (J,RCA,102,569,2014)                                   C215400100010 
           #doi:10.1515/ract-2013-2179                            C215400100011 
REL-REF    (I,,J.W.Weidner+,J,ARI,70,2602,2012) Detailed          C215400100012 
            description of experimental irradiations              C215400100013 
FACILITY   (LINAC,1USALAS) Irradiations were performed at the     C215400100014 
           Los Alamos National Laboratory's Neutron Science       C215400100015 
           Center (LANSCE), proton beams of approximately 90-120  C215400100016 
           nA intensities with incident energies of 100 and       C215400100017 
           200MeV.                                                C215400100018 
SAMPLE     Thorium foil stacks were used as a sample. Each stack  C215400100019 
           contained two sets of six thin thorium foils           C215400100020 
           separated by aluminum energy degraders.                C215400100021 
METHOD     (ACTIV,CHSEP)                                          C215400100022 
MONITOR    (13-AL-27(P,X)11-NA-22,,SIG)                           C215400100023 
ERR-ANALYS (DATA-ERR) No information given                        C215400100024 
HISTORY    (20150204C) Compiled by S.H.                           C215400100025 
           (20241025A) OS. DECAY-DATA in sub.2 corrected          C215400100026 
ENDBIB              24          0                                 C215400100027 
NOCOMMON             0          0                                 C215400100028 
ENDSUBENT           27          0                                 C215400199999 
SUBENT        C2154002   20241031   20250110                      C215400200001 
BIB                  6         17                                 C215400200002 
REACTION   (90-TH-232(P,X)89-AC-227,CUM,SIG)                      C215400200003 
STATUS     (TABLE,,J.W.Engle+,J,RCA,102,569,2014) Tab.3.          C215400200004 
DETECTOR   (SIBAR) Samples were assayed in eight chambers, each   C215400200005 
           with a 300mm2 ruggedized Si surface barrier detector   C215400200006 
           having a depletion depth of 100 mu-m, under a          C215400200007 
           pressure of approximately 10 millitorr.                C215400200008 
DECAY-DATA (89-AC-227,21.8YR)                                     C215400200009 
           (90-TH-227,18.68D)                                     C215400200010 
           (88-RA-223,11.43D)                                     C215400200011 
           (86-RN-219,3.96SEC)                                    C215400200012 
           (84-PO-215,1.781MSEC,A,7390.,0.999998)                 C215400200013 
METHOD     Amount of reduced 227Ac was determined from its decay  C215400200014 
           product 215Po. To reach equilibrium with 215Po parents C215400200015 
           to facilitate spectroscopic measurement required       C215400200016 
           approximately 100-day waiting period following         C215400200017 
           chemical separation                                    C215400200018 
HISTORY    (20241025A) DECAY-DATA: Energy corrected               C215400200019 
ENDBIB              17          0                                 C215400200020 
NOCOMMON             0          0                                 C215400200021 
DATA                 4         12                                 C215400200022 
EN         EN-ERR     DATA       DATA-ERR                         C215400200023 
MEV        MEV        MB         MB                               C215400200024 
      194.5        0.3       13.9        1.8                      C215400200025 
      178.3        0.7       14.2        1.8                      C215400200026 
      160.7        1.0       15.5        1.9                      C215400200027 
      141.8        1.3       14.2        1.8                      C215400200028 
      120.9        1.6       10.9        1.4                      C215400200029 
       97.0        2.0        8.8        1.1                      C215400200030 
       90.8        0.4        6.6        0.8                      C215400200031 
       81.7        0.6        5.6        0.7                      C215400200032 
       72.8        0.7        2.8        0.3                      C215400200033 
       64.9        0.9        2.6        0.3                      C215400200034 
       56.3        1.1        2.1        0.2                      C215400200035 
       44.0        1.4        4.0        0.5                      C215400200036 
ENDDATA             14          0                                 C215400200037 
ENDSUBENT           36          0                                 C215400299999 
SUBENT        C2154003   20150204                             C150C215400300001 
BIB                  4          7                                 C215400300002 
REACTION   (90-TH-232(P,X)89-AC-226,CUM,SIG)                      C215400300003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400300004 
DETECTOR   (SIBAR) Samples were assayed in eight chambers, each   C215400300005 
           with a 300mm2 ruggedized Si surface barrier detector   C215400300006 
           having a depletion depth of 100 mu-m, under a          C215400300007 
           pressure of approximately 10 millitorr.                C215400300008 
DECAY-DATA (89-AC-226,29.4HR)                                     C215400300009 
ENDBIB               7          0                                 C215400300010 
NOCOMMON             0          0                                 C215400300011 
DATA                 4         12                                 C215400300012 
EN         EN-ERR     DATA       DATA-ERR                         C215400300013 
MEV        MEV        MB         MB                               C215400300014 
      194.5        0.3       15.7        1.1                      C215400300015 
      178.3        0.7       17.2        1.3                      C215400300016 
      160.7        1.0       16.0        1.1                      C215400300017 
      141.8        1.3       14.2        1.3                      C215400300018 
      120.9        1.6       12.8        0.8                      C215400300019 
       97.0        2.0        8.4        0.5                      C215400300020 
       90.8        0.4        7.5        0.4                      C215400300021 
       81.7        0.6        4.9        1.4                      C215400300022 
       72.8        0.7        4.3        0.2                      C215400300023 
       64.9        0.9        4.9        0.2                      C215400300024 
       56.3        1.1        5.0        1.3                      C215400300025 
       44.0        1.4        3.5        0.8                      C215400300026 
ENDDATA             14          0                                 C215400300027 
ENDSUBENT           26          0                                 C215400399999 
SUBENT        C2154004   20150204                             C150C215400400001 
BIB                  4          8                                 C215400400002 
REACTION   (90-TH-232(P,X)58-CE-139,CUM,SIG)                      C215400400003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400400004 
DETECTOR   (HPGE) Following the separation the samples were       C215400400005 
           counted on an HPGe detector (1min count length), and   C215400400006 
           the integrated counts were compared with those         C215400400007 
           obtained from the 5mL standards counted in the same    C215400400008 
           geometry.                                              C215400400009 
DECAY-DATA (58-CE-139-G,137.64D,DG,166.0,0.800)                   C215400400010 
ENDBIB               8          0                                 C215400400011 
NOCOMMON             0          0                                 C215400400012 
DATA                 4          9                                 C215400400013 
EN         EN-ERR     DATA       DATA-ERR                         C215400400014 
MEV        MEV        MB         MB                               C215400400015 
      194.5        0.3        2.1        0.2                      C215400400016 
      178.3        0.7        2.2        0.2                      C215400400017 
      160.7        1.0        2.1        0.1                      C215400400018 
      141.8        1.3        1.9        0.2                      C215400400019 
      120.9        1.6        1.5        0.1                      C215400400020 
       97.0        2.0        1.1        0.2                      C215400400021 
       90.8        0.4        0.9        0.4                      C215400400022 
       81.7        0.6        0.9        0.6                      C215400400023 
       72.8        0.7        0.2        0.0                      C215400400024 
ENDDATA             11          0                                 C215400400025 
ENDSUBENT           24          0                                 C215400499999 
SUBENT        C2154005   20150204                             C150C215400500001 
BIB                  4          8                                 C215400500002 
REACTION   (90-TH-232(P,X)58-CE-141,CUM,SIG)                      C215400500003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400500004 
DETECTOR   (HPGE) Following the separation the samples were       C215400500005 
           counted on an HPGe detector (1min count length), and   C215400500006 
           the integrated counts were compared with those         C215400500007 
           obtained from the 5mL standards counted in the same    C215400500008 
           geometry.                                              C215400500009 
DECAY-DATA (58-CE-141,32.51D,DG,145.0,0.4829)                     C215400500010 
ENDBIB               8          0                                 C215400500011 
NOCOMMON             0          0                                 C215400500012 
DATA                 4         12                                 C215400500013 
EN         EN-ERR     DATA       DATA-ERR                         C215400500014 
MEV        MEV        MB         MB                               C215400500015 
      194.5        0.3       13.1        0.9                      C215400500016 
      178.3        0.7       15.8        1.2                      C215400500017 
      160.7        1.0       16.3        4.0                      C215400500018 
      141.8        1.3       17.0        1.9                      C215400500019 
      120.9        1.6       19.8        1.4                      C215400500020 
       97.0        2.0       24.5        2.7                      C215400500021 
       90.8        0.4       24.7        1.2                      C215400500022 
       81.7        0.6       25.9        1.2                      C215400500023 
       72.8        0.7       26.5        1.2                      C215400500024 
       64.9        0.9       28.1        1.2                      C215400500025 
       56.3        1.1       28.4        1.1                      C215400500026 
       44.0        1.4       30.4        1.6                      C215400500027 
ENDDATA             14          0                                 C215400500028 
ENDSUBENT           27          0                                 C215400599999 
SUBENT        C2154006   20150204                             C150C215400600001 
BIB                  4          8                                 C215400600002 
REACTION   (90-TH-232(P,X)58-CE-143,CUM,SIG)                      C215400600003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400600004 
DETECTOR   (HPGE) Following the separation the samples were       C215400600005 
           counted on an HPGe detector (1min count length), and   C215400600006 
           the integrated counts were compared with those         C215400600007 
           obtained from the 5mL standards counted in the same    C215400600008 
           geometry.                                              C215400600009 
DECAY-DATA (58-CE-143,33.04HR,DG,293.0,0.428)                     C215400600010 
ENDBIB               8          0                                 C215400600011 
NOCOMMON             0          0                                 C215400600012 
DATA                 4         12                                 C215400600013 
EN         EN-ERR     DATA       DATA-ERR                         C215400600014 
MEV        MEV        MB         MB                               C215400600015 
      194.5        0.3        7.7        0.5                      C215400600016 
      178.3        0.7        9.3        0.7                      C215400600017 
      160.7        1.0        9.6        0.6                      C215400600018 
      141.8        1.3       10.9        0.7                      C215400600019 
      120.9        1.6       13.4        1.6                      C215400600020 
       97.0        2.0       15.2        1.7                      C215400600021 
       90.8        0.4       15.2        0.8                      C215400600022 
       81.7        0.6       16.4        0.8                      C215400600023 
       72.8        0.7       17.8        0.8                      C215400600024 
       64.9        0.9       19.9        1.0                      C215400600025 
       56.3        1.1       21.7        1.0                      C215400600026 
       44.0        1.4       24.3        1.4                      C215400600027 
ENDDATA             14          0                                 C215400600028 
ENDSUBENT           27          0                                 C215400699999 
SUBENT        C2154007   20150204                             C150C215400700001 
BIB                  4          8                                 C215400700002 
REACTION   (90-TH-232(P,X)57-LA-140,IND,SIG)                      C215400700003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400700004 
DETECTOR   (HPGE) Following the separation the samples were       C215400700005 
           counted on an HPGe detector (1min count length), and   C215400700006 
           the integrated counts were compared with those         C215400700007 
           obtained from the 5mL standards counted in the same    C215400700008 
           geometry.                                              C215400700009 
DECAY-DATA (57-LA-140,1.68D,DG,1596.0,0.954)                      C215400700010 
ENDBIB               8          0                                 C215400700011 
NOCOMMON             0          0                                 C215400700012 
DATA                 4         12                                 C215400700013 
EN         EN-ERR     DATA       DATA-ERR                         C215400700014 
MEV        MEV        MB         MB                               C215400700015 
      194.5        0.3        2.6        0.2                      C215400700016 
      178.3        0.7        2.8        0.4                      C215400700017 
      160.7        1.0        3.2        0.3                      C215400700018 
      141.8        1.3        3.5        0.3                      C215400700019 
      120.9        1.6        3.9        0.2                      C215400700020 
       97.0        2.0        4.9        0.7                      C215400700021 
       90.8        0.4        4.9        0.3                      C215400700022 
       81.7        0.6        5.3        0.3                      C215400700023 
       72.8        0.7        5.8        0.3                      C215400700024 
       64.9        0.9        6.0        0.3                      C215400700025 
       56.3        1.1        5.6        0.4                      C215400700026 
       44.0        1.4        3.9        0.6                      C215400700027 
ENDDATA             14          0                                 C215400700028 
ENDSUBENT           27          0                                 C215400799999 
SUBENT        C2154008   20150204                             C150C215400800001 
BIB                  4          8                                 C215400800002 
REACTION   (90-TH-232(P,X)56-BA-140,CUM,SIG)                      C215400800003 
STATUS     (TABLE) Data taken from tab. 3 of the reference        C215400800004 
DETECTOR   (HPGE) Following the separation the samples were       C215400800005 
           counted on an HPGe detector (1min count length), and   C215400800006 
           the integrated counts were compared with those         C215400800007 
           obtained from the 5mL standards counted in the same    C215400800008 
           geometry.                                              C215400800009 
DECAY-DATA (56-BA-140,12.75D)                                     C215400800010 
ENDBIB               8          0                                 C215400800011 
NOCOMMON             0          0                                 C215400800012 
DATA                 4         12                                 C215400800013 
EN         EN-ERR     DATA       DATA-ERR                         C215400800014 
MEV        MEV        MB         MB                               C215400800015 
      194.5        0.3        8.0        0.8                      C215400800016 
      178.3        0.7       10.0        0.8                      C215400800017 
      160.7        1.0       10.6        0.8                      C215400800018 
      141.8        1.3       12.0        0.8                      C215400800019 
      120.9        1.6       13.6        0.9                      C215400800020 
       97.0        2.0       16.8        1.9                      C215400800021 
       90.8        0.4       17.1        1.1                      C215400800022 
       81.7        0.6       18.5        1.1                      C215400800023 
       72.8        0.7       19.7        1.2                      C215400800024 
       64.9        0.9       22.3        1.4                      C215400800025 
       56.3        1.1       25.8        1.4                      C215400800026 
       44.0        1.4       30.9        2.0                      C215400800027 
ENDDATA             14          0                                 C215400800028 
ENDSUBENT           27          0                                 C215400899999 
ENDENTRY             8          0                                 C215499999999