ENTRY C0911 20030424 0000C091100000001 SUBENT C0911001 20030424 0000C091100100001 BIB 10 13 C091100100002 INSTITUTE (1CANTOR,1CANOTC) C091100100003 REFERENCE (J,CJP,49,1397,1971) C091100100004 AUTHOR (D.W.O.Rogers,J.H.Aitken,A.E.Litherland,W.R.Dixon, C091100100005 R.S.Storey) C091100100006 TITLE Radiative Width of the 6+ Level in 20Ne at 8.78 MeV C091100100007 FACILITY (VDG,1CANOTC) C091100100008 METHOD (GSPEC) C091100100009 DETECTOR (GELI) 2 Ge(Li) detectors situated at 0 and 90 degs. C091100100010 to beam axis. C091100100011 MONITOR Detector efficiency determined using 60Co calibrated C091100100012 source. C091100100013 STATUS Data taken from reference. C091100100014 HISTORY (20030424C) VM C091100100015 ENDBIB 13 0 C091100100016 NOCOMMON 0 0 C091100100017 ENDSUBENT 16 0 C091100199999 SUBENT C0911002 20030424 0000C091100200001 BIB 3 10 C091100200002 REACTION 1(8-O-16(A,G),,WID/STR) C091100200003 2(8-O-16(A,G),,WID) C091100200004 ANALYSIS 2Assumed alpha width much greater than gamma width. C091100200005 ERR-ANALYS (DATA-ERR) Major contributions due to uncertainty in: C091100200006 . absolute Ge(Li) detector efficiency at 4.53 MeV C091100200007 (10%), C091100200008 . uncertainty in value of stopping power (10%), C091100200009 . counting statistics (4%), C091100200010 . finite size of the detector (2%), C091100200011 . measurement of current (3%). C091100200012 ENDBIB 10 0 C091100200013 NOCOMMON 0 0 C091100200014 DATA 5 1 C091100200015 EN-RES DATA 1DATA-ERR 1DATA 2DATA-ERR 2 C091100200016 MEV EV EV EV EV C091100200017 5.06 1.30 0.20 0.100 0.015 C091100200018 ENDDATA 3 0 C091100200019 ENDSUBENT 18 0 C091100299999 ENDENTRY 2 0 C091199999999