ENTRY C0499 20230802 C049900000001 SUBENT C0499001 20230802 20240513 C049900100001 BIB 15 42 C049900100002 INSTITUTE (1USAMHG) C049900100003 REFERENCE (J,PR/C,40,1563,1989) C049900100004 #doi:10.1103/PhysRevC.40.R1563 C049900100005 (T,SAAM,1989) Measurement report C049900100006 AUTHOR (B.Saam,M.Skalsey,J.Van House) C049900100007 TITLE Measurement of the cross section of 22Ne(p,n)22Na C049900100008 FACILITY (CYCLO,1USAMHG) PET facility at U. Michigan Medical C049900100009 School. C049900100010 INC-SPECT Metallic absorbers of Ta, Ni, and stainless steel used C049900100011 at entrance window of cell to degrade initial proton C049900100012 energy of 26 MeV. Energy controlled by adjusting C049900100013 thickness of absorbers. C049900100014 SAMPLE Natural Ne (9.2% 22Ne) gas cell with aluminum internal C049900100015 walls, a removeable Monel liner, and copper end C049900100016 flange. C049900100017 (10-NE-22,NAT=0.092) C049900100018 METHOD (ACTIV) All 22Na produced was bound to Monel liner in C049900100019 cell. Liner was removed from cell after activation C049900100020 for counting. C049900100021 DETECTOR (GE-IN) C049900100022 MONITOR Sealed 22Na calibration sources. C049900100023 DECAY-DATA (11-NA-22,,DG,1274.) C049900100024 CORRECTION Corrected for C049900100025 . background counts in end window, C049900100026 . nonuniform activity distribution, C049900100027 . neon gas density reduction effect. C049900100028 ERR-ANALYS (EN-ERR1) Uncertainty in proton energy at gas cell C049900100029 entrance C049900100030 (EN-ERR2) Uncertainty in proton energy at gas cell exitC049900100031 (ERR-T) Sum in quadrature of uncertainties in C049900100032 (ERR-1) density reduction calculation (10%), C049900100033 (ERR-2) intensity of calibration sources (6%), C049900100034 (ERR-3) pressure reading (5%), C049900100035 (ERR-4) measurement of integrated charge (3.5%), C049900100036 (ERR-S) statistical uncertainties (3%). C049900100037 STATUS (APRVD) Approved by M. Skalsey, 26 July 1999. C049900100038 (TABLE) Data received by email from M. Skalsey, C049900100039 25 Feb 1999. C049900100040 Measurement reported in senior thesis, B.T. Saam 1989. C049900100041 HISTORY (19990623C) VM C049900100042 (19990726A) BIB update; data heading corrected. C049900100043 (20230715A) OS. ERR-ANALYS updated, 2nd reference addedC049900100044 ENDBIB 42 0 C049900100045 COMMON 5 3 C049900100046 ERR-1 ERR-2 ERR-3 ERR-4 ERR-S C049900100047 PER-CENT PER-CENT PER-CENT PER-CENT PER-CENT C049900100048 10. 6. 5. 3.5 3. C049900100049 ENDCOMMON 3 0 C049900100050 ENDSUBENT 49 0 C049900199999 SUBENT C0499002 20230802 20240513 C049900200001 BIB 2 4 C049900200002 REACTION (10-NE-22(P,N)11-NA-22,,SIG) C049900200003 HISTORY (20230715A) EN-ERR (in COMMON) changed to EN-ERR1, C049900200004 EN-ERR (in DATA table) changed to EN-ERR2, C049900200005 DATA-ERR changed to ERR-T C049900200006 ENDBIB 4 0 C049900200007 COMMON 1 3 C049900200008 EN-ERR1 C049900200009 MEV C049900200010 0.5 C049900200011 ENDCOMMON 3 0 C049900200012 DATA 4 3 C049900200013 EN EN-ERR2 DATA ERR-T C049900200014 MEV MEV MB MB C049900200015 7.3 1.3 190. 30. C049900200016 12.0 1.0 180. 30. C049900200017 16.1 0.8 90. 15. C049900200018 ENDDATA 5 0 C049900200019 ENDSUBENT 18 0 C049900299999 ENDENTRY 2 0 C049999999999