ENTRY C0375 20220824 C037500000001 SUBENT C0375001 20220824 20230412 C037500100001 BIB 10 19 C037500100002 INSTITUTE (1USABNL) C037500100003 REFERENCE (J,PR,129,1809,1963) C037500100004 AUTHOR (G.Friedlander,L.Friedman,B.Gordon,L.Yaffe) C037500100005 TITLE Excitation functions and nuclear charge dispersion in C037500100006 the fission of uranium by 0.1- to 6.2-GeV protons C037500100007 SAMPLE Natural uranium foils. C037500100008 METHOD (ACTIV,CHSEP,ASEP) C037500100009 DETECTOR (NAICR,PROPC) C037500100010 ERR-ANALYS (DATA-ERR) Errors include uncertainties in decay curve C037500100011 analysis, counting efficiencies and chemical yields. C037500100012 Average values were obtained by weighting the indivi- C037500100013 dual results by reciprocals of their errors, and mean C037500100014 deviations were calculated without weighting factors. C037500100015 STATUS (TABLE) Data taken from PR,129,1809,1963--Tables I, II,C037500100016 IV and V. C037500100017 HISTORY (19870915C) C037500100018 (20220823A) OS. Updated ERR-ANALYS, modified monitor C037500100019 reaction coding, converted to lower case, corrections C037500100020 of DECAY-DATA in many subentries C037500100021 ENDBIB 19 0 C037500100022 NOCOMMON 0 0 C037500100023 ENDSUBENT 22 0 C037500199999 SUBENT C0375002 20220824 20230412 C037500200001 BIB 5 7 C037500200002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037500200003 DECAY-DATA ((1.)57-LA-140,40.2HR,B-,2200.,1.0) C037500200004 ((2.)55-CS-129,32.4HR,XR) C037500200005 ((3.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037500200006 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500200007 FACILITY (CYCLO,1USACOL) C037500200008 HISTORY (20220823A) Decay data coding corrected C037500200009 ENDBIB 7 0 C037500200010 COMMON 2 3 C037500200011 EN MONIT C037500200012 GEV MB C037500200013 0.10 10.8 C037500200014 ENDCOMMON 3 0 C037500200015 DATA 7 8 C037500200016 ELEMENT MASS DECAY-FLAG DATA DATA-ERR DATA-MAX C037500200017 DATA-APRX C037500200018 NO-DIM NO-DIM NO-DIM MB MB MB C037500200019 MB C037500200020 57. 131. C037500200021 0.01 C037500200022 56. 140. 1. 25.4 0.4 C037500200023 C037500200024 56. 129. 0.0017 0.0002 C037500200025 C037500200026 55. 137. 37. 1. C037500200027 C037500200028 55. 135. 52. 2. C037500200029 C037500200030 55. 129. 2. 0.05 0.03 C037500200031 C037500200032 55. 127. 3. 0.12 C037500200033 C037500200034 37. 87. 10. 3. C037500200035 C037500200036 ENDDATA 20 0 C037500200037 ENDSUBENT 36 0 C037500299999 SUBENT C0375003 20220824 20230412 C037500300001 BIB 5 10 C037500300002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037500300003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037500300004 ((2.)55-CS-132,6.48D,XR) C037500300005 ((3.)55-CS-131,9.69D,XR) C037500300006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037500300007 ((5.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037500300008 ((6.)37-RB-84-G,33.D,B-/B+) C037500300009 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500300010 FACILITY (CYCLO,1USACOL) C037500300011 HISTORY (20220823A) Decay data coding corrected C037500300012 ENDBIB 10 0 C037500300013 COMMON 2 3 C037500300014 EN MONIT C037500300015 GEV MB C037500300016 0.10 10.8 C037500300017 ENDCOMMON 3 0 C037500300018 DATA 6 8 C037500300019 ELEMENT MASS DECAY-FLAG DATA DATA-ERR DATA-MAX C037500300020 NO-DIM NO-DIM NO-DIM MB MB MB C037500300021 56. 131. 0.03 0.01 C037500300022 55. 136. 1. 14.7 1.3 C037500300023 55. 134. 11.0 0.3 C037500300024 55. 132. 2. 3.7 0.2 C037500300025 55. 131. 3. 1.53 0.10 C037500300026 55. 130. 4. 0.58 0.05 C037500300027 37. 86. 5. 0.6 0.2 C037500300028 37. 84. 6. 0.04 C037500300029 ENDDATA 10 0 C037500300030 ENDSUBENT 29 0 C037500399999 SUBENT C0375004 20220824 20230412 C037500400001 BIB 5 8 C037500400002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037500400003 DECAY-DATA ((1.)57-LA-140,40.2HR,B-,2200.,1.0) C037500400004 ((2.)55-CS-129,32.4HR,XR) C037500400005 ((3.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037500400006 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500400007 FACILITY (CYCLO,1USACOL) C037500400008 (SYNCY,1USACHI) C037500400009 HISTORY (20220823A) Decay data coding corrected C037500400010 ENDBIB 8 0 C037500400011 COMMON 2 3 C037500400012 EN MONIT C037500400013 GEV MB C037500400014 0.20 10.8 C037500400015 ENDCOMMON 3 0 C037500400016 DATA 6 8 C037500400017 ELEMENT MASS DECAY-FLAG DATA DATA-ERR DATA-MAX C037500400018 NO-DIM NO-DIM NO-DIM MB MB MB C037500400019 57. 131. 0.09 C037500400020 56. 140. 1. 19.1 0.1 C037500400021 56. 129. 0.12 0.01 C037500400022 55. 137. 23.0 0.5 C037500400023 55. 135. 33.8 1.5 C037500400024 55. 129. 2. 1.7 0.3 C037500400025 55. 127. 3. 0.3 0.1 C037500400026 37. 87. 20. 2. C037500400027 ENDDATA 10 0 C037500400028 ENDSUBENT 27 0 C037500499999 SUBENT C0375005 20220824 20230412 C037500500001 BIB 5 12 C037500500002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037500500003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037500500004 ((2.)55-CS-132,6.48D,XR) C037500500005 ((3.)55-CS-131,9.69D,XR) C037500500006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037500500007 ((5.)55-CS-129,32.4HR,XR) C037500500008 ((6.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037500500009 ((7.)37-RB-84-G,33.D,B-/B+) C037500500010 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500500011 FACILITY (CYCLO,1USACOL) C037500500012 (SYNCY,1USACHI) C037500500013 HISTORY (20220823A) Decay data coding corrected C037500500014 ENDBIB 12 0 C037500500015 COMMON 2 3 C037500500016 EN MONIT C037500500017 GEV MB C037500500018 0.20 10.8 C037500500019 ENDCOMMON 3 0 C037500500020 DATA 5 9 C037500500021 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037500500022 NO-DIM NO-DIM NO-DIM MB MB C037500500023 56. 131. 0.7 0.1 C037500500024 55. 136. 1. 9.9 0.6 C037500500025 55. 134. 8.6 0.4 C037500500026 55. 132. 2. 4.9 0.4 C037500500027 55. 131. 3. 3.8 0.4 C037500500028 55. 130. 4. 2.2 0.4 C037500500029 55. 129. 5. 1.55 0.4 C037500500030 37. 86. 6. 2.3 0.1 C037500500031 37. 84. 7. 0.8 0.1 C037500500032 ENDDATA 11 0 C037500500033 ENDSUBENT 32 0 C037500599999 SUBENT C0375006 20220824 20230412 C037500600001 BIB 3 3 C037500600002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037500600003 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500600004 FACILITY (SYNCY,1USACHI) C037500600005 ENDBIB 3 0 C037500600006 COMMON 2 3 C037500600007 EN MONIT C037500600008 GEV MB C037500600009 0.30 10.8 C037500600010 ENDCOMMON 3 0 C037500600011 DATA 4 3 C037500600012 ELEMENT MASS DATA DATA-ERR C037500600013 NO-DIM NO-DIM MB MB C037500600014 56. 131. 2.2 0.7 C037500600015 55. 137. 16.8 0.6 C037500600016 55. 135. 24.7 0.8 C037500600017 ENDDATA 5 0 C037500600018 ENDSUBENT 17 0 C037500699999 SUBENT C0375007 20220824 20230412 C037500700001 BIB 4 5 C037500700002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037500700003 DECAY-DATA ((1.)55-CS-132,6.48D,XR) C037500700004 ((2.)55-CS-131,9.69D,XR) C037500700005 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500700006 FACILITY (SYNCY,1USACHI) C037500700007 ENDBIB 5 0 C037500700008 COMMON 2 3 C037500700009 EN MONIT C037500700010 GEV MB C037500700011 0.30 10.8 C037500700012 ENDCOMMON 3 0 C037500700013 DATA 5 3 C037500700014 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037500700015 NO-DIM NO-DIM NO-DIM MB MB C037500700016 55. 134. 7.4 0.3 C037500700017 55. 132. 1. 6.5 0.1 C037500700018 55. 131. 2. 5.1 0.5 C037500700019 ENDDATA 5 0 C037500700020 ENDSUBENT 19 0 C037500799999 SUBENT C0375008 20220824 20230412 C037500800001 BIB 5 8 C037500800002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037500800003 DECAY-DATA ((1.)57-LA-140,40.2HR,B-,2200.,1.0) C037500800004 ((2.)55-CS-129,32.4HR,XR) C037500800005 ((3.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037500800006 ((4.)55-CS-125,45.MIN,AR,511.,0.49) C037500800007 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500800008 FACILITY (CYCLO,1USACOL) C037500800009 HISTORY (20220823A) Decay data coding corrected C037500800010 ENDBIB 8 0 C037500800011 COMMON 2 3 C037500800012 EN MONIT C037500800013 GEV MB C037500800014 0.38 10.8 C037500800015 ENDCOMMON 3 0 C037500800016 DATA 6 11 C037500800017 ELEMENT MASS DECAY-FLAG DATA DATA-ERR DATA-MAX C037500800018 NO-DIM NO-DIM NO-DIM MB MB MB C037500800019 57. 131. 0.8 0.1 C037500800020 56. 140. 1. 14.6 0.4 C037500800021 56. 131. 2.69 0.02 C037500800022 56. 129. 0.90 0.05 C037500800023 55. 137. 16.7 0.2 C037500800024 55. 135. 25.4 0.1 C037500800025 55. 129. 2. 4.8 0.2 C037500800026 55. 127. 3. 1.21 0.05 C037500800027 55. 125. 4. 0.06 C037500800028 37. 87. 41. 3. C037500800029 37. 83. 0.6 C037500800030 ENDDATA 13 0 C037500800031 ENDSUBENT 30 0 C037500899999 SUBENT C0375009 20220824 20230412 C037500900001 BIB 5 11 C037500900002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037500900003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037500900004 ((2.)55-CS-132,6.48D,XR) C037500900005 ((3.)55-CS-131,9.69D,XR) C037500900006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037500900007 ((5.)55-CS-129,32.4HR,XR) C037500900008 ((6.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037500900009 ((7.)37-RB-84-G,33.D,B-/B+) C037500900010 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037500900011 FACILITY (CYCLO,1USACOL) C037500900012 HISTORY (20220823A) Decay data coding corrected C037500900013 ENDBIB 11 0 C037500900014 COMMON 2 3 C037500900015 EN MONIT C037500900016 GEV MB C037500900017 0.38 10.8 C037500900018 ENDCOMMON 3 0 C037500900019 DATA 5 9 C037500900020 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037500900021 NO-DIM NO-DIM NO-DIM MB MB C037500900022 56. 131. 1.9 0.1 C037500900023 55. 136. 1. 7.2 0.1 C037500900024 55. 134. 6.9 0.1 C037500900025 55. 132. 2. 6.2 0.2 C037500900026 55. 131. 3. 6.5 0.9 C037500900027 55. 130. 4. 5.1 0.9 C037500900028 55. 129. 5. 3.9 0.2 C037500900029 37. 86. 6. 5.6 0.7 C037500900030 37. 84. 7. 1.7 0.2 C037500900031 ENDDATA 11 0 C037500900032 ENDSUBENT 31 0 C037500999999 SUBENT C0375010 20220824 20230412 C037501000001 BIB 3 3 C037501000002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037501000003 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501000004 FACILITY (SYNCY,1USACHI) C037501000005 ENDBIB 3 0 C037501000006 COMMON 2 3 C037501000007 EN MONIT C037501000008 GEV MB C037501000009 0.45 10.8 C037501000010 ENDCOMMON 3 0 C037501000011 DATA 4 3 C037501000012 ELEMENT MASS DATA DATA-ERR C037501000013 NO-DIM NO-DIM MB MB C037501000014 55. 137. 14.1 0.7 C037501000015 55. 135. 20.7 0.9 C037501000016 37. 83. 1.4 0.1 C037501000017 ENDDATA 5 0 C037501000018 ENDSUBENT 17 0 C037501099999 SUBENT C0375011 20220824 20230412 C037501100001 BIB 5 6 C037501100002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037501100003 DECAY-DATA ((1.)55-CS-132,6.48D,XR) C037501100004 ((2.)37-RB-84-G,33.D,B+/B-) C037501100005 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501100006 FACILITY (SYNCY,1USACHI) C037501100007 HISTORY (20220823A) Decay data coding corrected C037501100008 ENDBIB 6 0 C037501100009 COMMON 2 3 C037501100010 EN MONIT C037501100011 GEV MB C037501100012 0.45 10.8 C037501100013 ENDCOMMON 3 0 C037501100014 DATA 5 3 C037501100015 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501100016 NO-DIM NO-DIM NO-DIM MB MB C037501100017 55. 134. 6.7 0.1 C037501100018 55. 132. 1. 7.1 0.8 C037501100019 37. 84. 2. 2.0 0.1 C037501100020 ENDDATA 5 0 C037501100021 ENDSUBENT 20 0 C037501199999 SUBENT C0375012 20220824 20230412 C037501200001 BIB 5 5 C037501200002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037501200003 DECAY-DATA ((1.)55-CS-129,32.4HR,XR) C037501200004 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501200005 FACILITY (SYNCY,1USABRK) C037501200006 HISTORY (20220823A) Decay data coding corrected C037501200007 ENDBIB 5 0 C037501200008 COMMON 2 3 C037501200009 EN MONIT C037501200010 GEV MB C037501200011 0.68 10.8 C037501200012 ENDCOMMON 3 0 C037501200013 DATA 5 5 C037501200014 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501200015 NO-DIM NO-DIM NO-DIM MB MB C037501200016 56. 131. 6.2 0.3 C037501200017 55. 137. 11.9 0.9 C037501200018 55. 135. 18.3 1.0 C037501200019 55. 129. 1. 6.4 0.4 C037501200020 37. 83. 3.6 1.2 C037501200021 ENDDATA 7 0 C037501200022 ENDSUBENT 21 0 C037501299999 SUBENT C0375013 20220824 20230412 C037501300001 BIB 5 9 C037501300002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037501300003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037501300004 ((2.)55-CS-132,6.48D,XR) C037501300005 ((3.)55-CS-131,9.69D,XR) C037501300006 ((4.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037501300007 ((5.)37-RB-84-G,33.D,B-/B+) C037501300008 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501300009 FACILITY (SYNCY,1USABRK) C037501300010 HISTORY (20220823A) Decay data coding corrected C037501300011 ENDBIB 9 0 C037501300012 COMMON 2 3 C037501300013 EN MONIT C037501300014 GEV MB C037501300015 0.68 10.8 C037501300016 ENDCOMMON 3 0 C037501300017 DATA 6 7 C037501300018 ELEMENT MASS DECAY-FLAG DATA DATA-ERR DATA-MAX C037501300019 NO-DIM NO-DIM NO-DIM MB MB MB C037501300020 55. 136. 1. 4.8 0.5 C037501300021 55. 134. 5.5 0.3 C037501300022 55. 132. 2. 5.9 0.3 C037501300023 55. 131. 3. 5.8 0.3 C037501300024 37. 86. 4. 8.3 0.5 C037501300025 37. 84. 5. 3.6 1.2 C037501300026 37. 83. 2.4 C037501300027 ENDDATA 9 0 C037501300028 ENDSUBENT 27 0 C037501399999 SUBENT C0375014 20220824 20230412 C037501400001 BIB 5 8 C037501400002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037501400003 DECAY-DATA ((1.)57-LA-140,40.2HR,B-,2200.,1.0) C037501400004 ((2.)55-CS-129,32.4HR,XR) C037501400005 ((3.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037501400006 ((4.)55-CS-125,45.MIN,AR,511.,0.49) C037501400007 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501400008 FACILITY (SYNCH,1USABNL) C037501400009 HISTORY (20220823A) Decay data coding corrected C037501400010 ENDBIB 8 0 C037501400011 COMMON 2 3 C037501400012 EN MONIT C037501400013 GEV MB C037501400014 1.0 10.4 C037501400015 ENDCOMMON 3 0 C037501400016 DATA 5 10 C037501400017 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501400018 NO-DIM NO-DIM NO-DIM MB MB C037501400019 57. 131. 2.4 0.1 C037501400020 56. 140. 1. 9.3 0.6 C037501400021 56. 131. 5.8 0.2 C037501400022 56. 129. 3.60 0.05 C037501400023 56. 127. 1.4 0.4 C037501400024 55. 137. 9.6 1.5 C037501400025 55. 135. 13. 2. C037501400026 55. 129. 2. 9.4 0.3 C037501400027 55. 127. 3. 4.4 0.4 C037501400028 55. 125. 4. 1.1 0.1 C037501400029 ENDDATA 12 0 C037501400030 ENDSUBENT 29 0 C037501499999 SUBENT C0375015 20220824 20230412 C037501500001 BIB 5 12 C037501500002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037501500003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037501500004 ((2.)55-CS-132,6.48D,XR) C037501500005 ((3.)55-CS-131,9.69D,XR) C037501500006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037501500007 ((5.)55-CS-129,32.4HR,XR) C037501500008 ((6.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037501500009 ((7.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037501500010 ((8.)37-RB-84-G,33.D,B-/B+) C037501500011 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501500012 FACILITY (SYNCH,1USABNL) C037501500013 HISTORY (20220823A) Decay data coding corrected C037501500014 ENDBIB 12 0 C037501500015 COMMON 2 3 C037501500016 EN MONIT C037501500017 GEV MB C037501500018 1.0 10.4 C037501500019 ENDCOMMON 3 0 C037501500020 DATA 5 10 C037501500021 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501500022 NO-DIM NO-DIM NO-DIM MB MB C037501500023 56. 131. 3.4 0.1 C037501500024 55. 136. 1. 4.4 0.3 C037501500025 55. 134. 3.0 0.5 C037501500026 55. 132. 2. 4.1 0.4 C037501500027 55. 131. 3. 5.4 0.9 C037501500028 55. 130. 4. 5.55 0.05 C037501500029 55. 129. 5. 6.45 0.05 C037501500030 55. 127. 6. 3.0 0.2 C037501500031 37. 86. 7. 10.8 0.7 C037501500032 37. 84. 8. 6.9 0.7 C037501500033 ENDDATA 12 0 C037501500034 ENDSUBENT 33 0 C037501599999 SUBENT C0375016 20220824 20230412 C037501600001 BIB 5 6 C037501600002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037501600003 DECAY-DATA ((1.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037501600004 ((2.)55-CS-125,45.MIN,AR,511.,0.49) C037501600005 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501600006 FACILITY (SYNCH,1USABNL) C037501600007 HISTORY (20220823A) Decay data coding corrected C037501600008 ENDBIB 6 0 C037501600009 COMMON 2 3 C037501600010 EN MONIT C037501600011 GEV MB C037501600012 2.0 9.5 C037501600013 ENDCOMMON 3 0 C037501600014 DATA 5 7 C037501600015 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501600016 NO-DIM NO-DIM NO-DIM MB MB C037501600017 57. 131. 4.40 0.05 C037501600018 56. 131. 6.8 0.2 C037501600019 56. 129. 5.4 0.2 C037501600020 55. 137. 10.8 0.6 C037501600021 55. 135. 14.7 1.7 C037501600022 55. 127. 1. 7.2 0.6 C037501600023 55. 125. 2. 2.7 0.5 C037501600024 ENDDATA 9 0 C037501600025 ENDSUBENT 24 0 C037501699999 SUBENT C0375017 20220824 20230412 C037501700001 BIB 5 11 C037501700002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037501700003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037501700004 ((2.)55-CS-132,6.48D,XR) C037501700005 ((3.)55-CS-131,9.69D,XR) C037501700006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037501700007 ((5.)55-CS-129,32.4HR,XR) C037501700008 ((6.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037501700009 ((7.)37-RB-84-G,33.D,B-/B+) C037501700010 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501700011 FACILITY (SYNCH,1USABNL) C037501700012 HISTORY (20220823A) Decay data coding corrected C037501700013 ENDBIB 11 0 C037501700014 COMMON 2 3 C037501700015 EN MONIT C037501700016 GEV MB C037501700017 2.0 9.5 C037501700018 ENDCOMMON 3 0 C037501700019 DATA 5 11 C037501700020 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501700021 NO-DIM NO-DIM NO-DIM MB MB C037501700022 56. 131. 2.40 0.05 C037501700023 55. 136. 1. 3.6 0.4 C037501700024 55. 135. 3.4 1.0 C037501700025 55. 134. 3.1 0.4 C037501700026 55. 132. 2. 3.8 0.4 C037501700027 55. 131. 3. 3.8 0.3 C037501700028 55. 130. 4. 4.3 0.2 C037501700029 55. 129. 5. 4.9 0.8 C037501700030 37. 86. 6. 9.5 0.6 C037501700031 37. 84. 7. 6.9 0.1 C037501700032 37. 83. 6.2 0.7 C037501700033 ENDDATA 13 0 C037501700034 ENDSUBENT 33 0 C037501799999 SUBENT C0375018 20220824 20230412 C037501800001 BIB 5 7 C037501800002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037501800003 DECAY-DATA ((1.)57-LA-140,40.2HR,B-,2200.,1.0) C037501800004 ((2.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037501800005 ((3.)55-CS-125,45.MIN,AR,511.,0.49) C037501800006 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501800007 FACILITY (SYNCH,1USABNL) C037501800008 HISTORY (20220823A) Decay data coding corrected C037501800009 ENDBIB 7 0 C037501800010 COMMON 2 3 C037501800011 EN MONIT C037501800012 GEV MB C037501800013 2.9 9.1 C037501800014 ENDCOMMON 3 0 C037501800015 DATA 5 9 C037501800016 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501800017 NO-DIM NO-DIM NO-DIM MB MB C037501800018 57. 131. 6.0 0.1 C037501800019 56. 140. 1. 7.9 0.2 C037501800020 56. 131. 8.55 0.05 C037501800021 56. 129. 6.7 0.3 C037501800022 56. 127. 4.7 0.4 C037501800023 55. 137. 8.8 0.5 C037501800024 55. 135. 12.0 0.2 C037501800025 55. 127. 2. 6.9 0.2 C037501800026 55. 125. 3. 3.9 0.2 C037501800027 ENDDATA 11 0 C037501800028 ENDSUBENT 27 0 C037501899999 SUBENT C0375019 20220824 20230412 C037501900001 BIB 5 12 C037501900002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037501900003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037501900004 ((2.)55-CS-132,6.48D,XR) C037501900005 ((3.)55-CS-131,9.69D,XR) C037501900006 ((4.)55-CS-130-G,30.MIN,B+,1970.,0.46) C037501900007 ((5.)55-CS-129,32.4HR,XR) C037501900008 ((6.)55-CS-127,6.2HR,AR,511.,0.035,XR) C037501900009 ((7.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037501900010 ((8.)37-RB-84-G,33.D,B-/B+) C037501900011 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037501900012 FACILITY (SYNCH,1USABNL) C037501900013 HISTORY (20220823A) Decay data coding corrected C037501900014 ENDBIB 12 0 C037501900015 COMMON 2 3 C037501900016 EN MONIT C037501900017 GEV MB C037501900018 2.9 9.1 C037501900019 ENDCOMMON 3 0 C037501900020 DATA 5 12 C037501900021 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037501900022 NO-DIM NO-DIM NO-DIM MB MB C037501900023 56. 131. 2.55 0.05 C037501900024 55. 136. 1. 3.20 0.05 C037501900025 55. 135. 2.0 0.6 C037501900026 55. 134. 2.8 0.1 C037501900027 55. 132. 2. 3.30 0.15 C037501900028 55. 131. 3. 3.7 0.5 C037501900029 55. 130. 4. 4.3 0.1 C037501900030 55. 129. 5. 5.0 0.5 C037501900031 55. 127. 6. 2.8 0.5 C037501900032 37. 86. 7. 8.5 0.5 C037501900033 37. 84. 8. 5.4 0.3 C037501900034 37. 83. 3.9 0.4 C037501900035 ENDDATA 14 0 C037501900036 ENDSUBENT 35 0 C037501999999 SUBENT C0375020 20220824 20230412 C037502000001 BIB 3 3 C037502000002 REACTION (92-U-0(P,X)ELEM/MASS,CUM,SIG) C037502000003 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037502000004 FACILITY (SYNCH,1USABRK) C037502000005 ENDBIB 3 0 C037502000006 COMMON 2 3 C037502000007 EN MONIT C037502000008 GEV MB C037502000009 6.2 8.7 C037502000010 ENDCOMMON 3 0 C037502000011 DATA 4 4 C037502000012 ELEMENT MASS DATA DATA-ERR C037502000013 NO-DIM NO-DIM MB MB C037502000014 56. 131. 6.6 0.9 C037502000015 56. 129. 13. 3. C037502000016 55. 137. 9.4 1.8 C037502000017 55. 135. 15. 5. C037502000018 ENDDATA 6 0 C037502000019 ENDSUBENT 18 0 C037502099999 SUBENT C0375021 20220824 20230412 C037502100001 BIB 5 8 C037502100002 REACTION (92-U-0(P,X)ELEM/MASS,,SIG) C037502100003 DECAY-DATA ((1.)55-CS-136-G,12.93D,B-,340.,,B-,660.) C037502100004 ((2.)55-CS-131,9.69D,XR) C037502100005 ((3.)37-RB-86-G,18.6D,B-,230.,,B-,710.,,B-,1800.) C037502100006 ((4.)37-RB-84-G,33.D,B-/B+) C037502100007 MONITOR ((MONIT)13-AL-27(P,X)11-NA-24,,SIG) C037502100008 FACILITY (SYNCH,1USABRK) C037502100009 HISTORY (20220823A) Decay data coding corrected C037502100010 ENDBIB 8 0 C037502100011 COMMON 2 3 C037502100012 EN MONIT C037502100013 GEV MB C037502100014 6.2 8.7 C037502100015 ENDCOMMON 3 0 C037502100016 DATA 5 4 C037502100017 ELEMENT MASS DECAY-FLAG DATA DATA-ERR C037502100018 NO-DIM NO-DIM NO-DIM MB MB C037502100019 55. 136. 1. 2.9 0.3 C037502100020 55. 131. 2. 2.4 1.1 C037502100021 37. 86. 3. 6.9 0.4 C037502100022 37. 84. 4. 5.2 1.1 C037502100023 ENDDATA 6 0 C037502100024 ENDSUBENT 23 0 C037502199999 ENDENTRY 21 0 C037599999999