ENTRY 33181 20230120 3318100000001 SUBENT 33181001 20230120 20231011 3318100100001 BIB 12 30 3318100100002 TITLE Systematic study of the (n, 2n) reaction cross 3318100100003 section for 121Sb and 123Sb isotopes 3318100100004 AUTHOR (R.K.Singh, N.L.Singh, R.D.Chauhan, M.Mehta, 3318100100005 S.V.Suryanarayana, R.Makwana, B.K.Nayak, H.Naik, 3318100100006 T.N.Nag, K.Katovsky) 3318100100007 INSTITUTE (3INDBDA,3INDTRM) 3318100100008 (3INDIND) Netaji Subhas University of Technology, Delhi3318100100009 (3INDIND) Institute for Plasma Research, Gandhinagar 3318100100010 (3CZRCZR) Brno University of Technology, Brno, Czech 3318100100011 Republic 3318100100012 REFERENCE (J,CHP,46,054002,2022) 3318100100013 FACILITY (VDGT,3INDTRM) 14UD BARC-TIFR Pelletron accelerator 3318100100014 INC-SOURCE (P-LI7) NatLi foil target of thickness 8.0 mg/cm2 3318100100015 was pasted on 0.1-mm-thick tantalum foil to stop the 3318100100016 proton beam along with a 4.0 mg/cm2 thick front 3318100100017 tantalum foil. 3318100100018 The proton beam energies were 15, 18 and 21 MeV. 3318100100019 The beam current was 150-160 nA. 3318100100020 DETECTOR (HPGE) The energy resolution was 3.305 keV at 1408 keV 3318100100021 gamma-ray 3318100100022 MONITOR (13-AL-27(N,A)11-NA-24,,SIG) 3318100100023 DECAY-MON (11-NA-24,14.99HR,DG,1368.62,0.9999) 3318100100024 ERR-ANALYS (ERR-T) Total error in the measured cross-sections are:3318100100025 (ERR-S,,5.) Counting statistics (<= 5%) 3318100100026 (ERR-1,,1.) Isotopic abundance (<= 1%) 3318100100027 (ERR-2,,4.) Detector efficiency (<= 4%) 3318100100028 (ERR-3,,0.01) Weight of the samples (<= 0.01%) 3318100100029 (ERR-4,,1.) Self-absorption of gamma-ray (<=1%) 3318100100030 STATUS (TABLE) Table 3 of Chin.Phys.C46(2022)054002 3318100100031 HISTORY (20230120C) VT+On. 3318100100032 ENDBIB 30 0 3318100100033 NOCOMMON 0 0 3318100100034 ENDSUBENT 33 0 3318100199999 SUBENT 33181002 20230120 20231011 3318100200001 BIB 4 7 3318100200002 REACTION (51-SB-121(N,2N)51-SB-120-M,,SIG,,SPA) 3318100200003 DECAY-DATA (51-SB-120-M,5.76D,DG,1171.3,1.00) 3318100200004 SAMPLE (51-SB-121,NAT=0.5738) 3318100200005 The Sb pellet (601 mg wt., 0.07 cm thick) 3318100200006 Al metal foil (25.6 mg wt., 0.01 cm thick) 3318100200007 METHOD (ACTIV) The irradiation time is 32700 sec, cooling time3318100200008 is 20986 sec and counting time is 1930 sec. 3318100200009 ENDBIB 7 0 3318100200010 NOCOMMON 0 0 3318100200011 DATA 6 3 3318100200012 EN EN-RSL-HW DATA ERR-T MONIT MONIT-ERR 3318100200013 MEV MEV MB MB MB MB 3318100200014 12.50 0.68 424.47 46.35 118.94 0.0793318100200015 15.79 0.55 596.25 94.37 114.38 0.0673318100200016 18.87 0.59 633.68 55.17 55.74 0.1083318100200017 ENDDATA 5 0 3318100200018 ENDSUBENT 17 0 3318100299999 SUBENT 33181003 20230120 20231011 3318100300001 BIB 4 7 3318100300002 REACTION (51-SB-123(N,2N)51-SB-122,,SIG,,SPA) 3318100300003 DECAY-DATA (51-SB-122-G,2.72D,DG,564.12,0.7068) 3318100300004 SAMPLE (51-SB-123,NAT=0.4264) 3318100300005 The Sb pellet (602 mg wt., 0.07 cm thick) 3318100300006 Al metal foil (25.9 mg wt., 0.01 cm thick) 3318100300007 METHOD (ACTIV) The irradiation time is 25200 sec, cooling time3318100300008 is 21475 sec and counting time is 1244 sec. 3318100300009 ENDBIB 7 0 3318100300010 NOCOMMON 0 0 3318100300011 DATA 6 3 3318100300012 EN EN-RSL-HW DATA ERR-T MONIT MONIT-ERR 3318100300013 MEV MEV MB MB MB MB 3318100300014 12.50 0.68 1371.74 130.56 118.94 0.0793318100300015 15.79 0.55 1570.29 233.34 114.38 0.0673318100300016 18.87 0.59 1412.50 101.63 55.74 0.1083318100300017 ENDDATA 5 0 3318100300018 ENDSUBENT 17 0 3318100399999 ENDENTRY 3 0 3318199999999