ENTRY 33164 20220830 32083316400000001 SUBENT 33164001 20220830 32083316400100001 BIB 15 40 3316400100002 TITLE Measurement of 100Mo(n,2n)99Mo reaction cross section 3316400100003 and covariance analysis using extended unscented 3316400100004 transformation technique at the incident neutron energy3316400100005 of 13.9 MeV 3316400100006 AUTHOR (S.P.Ram, J.Nair, S.V.Suryanarayana, L.S.Dhanu, 3316400100007 H.Naik, S.Ganesan) 3316400100008 INSTITUTE (3INDTRM) 3316400100009 (3INDIND) V.E.S. Institute of Technology, Mumbai 3316400100010 REFERENCE (J,IPA,58,351,2020) 3316400100011 FACILITY (CCW,3INDTRM) Purnima neutron generator 3316400100012 SAMPLE The molybdenum sample of weight 165.8 mg and square of 3316400100013 area 2.0 X 2.0 cm2. 3316400100014 The monitor were wrapped with 0.011 mm thick aluminum 3316400100015 foil. 3316400100016 DETECTOR (HPGE) 3316400100017 METHOD (ACTIV) The irradiation was carried out for 1.5 hours. 3316400100018 INC-SOURCE (D-T) 3316400100019 MONITOR (79-AU-197(N,2N)79-AU-196,,SIG) 3316400100020 DECAY-MON (79-AU-196-G,148.0HR,DG,355.7,0.870) 3316400100021 COMMENT By Sangeetha Prasanna Ram (2021-10-06): 3316400100022 The unit of uncertainties in Table 5 is barn. 3316400100023 The data combined by weighted average method to provide3316400100024 a single cross section value 3316400100025 ERR-ANALYS (ERR-T) Total uncertainty propagated from 3316400100026 (ERR-1,,,F) Monitor reaction cross section 3316400100027 (ERR-2,,,U) Gamma-ray peak count, 99Mo 3316400100028 (ERR-3,,,U) Gamma-ray peak count, Au 3316400100029 (ERR-4,,,F) Half life, 99Mo 3316400100030 (ERR-5,,,F) Half life, Au 3316400100031 (ERR-6,,,F) Atomic mass, 99Mo 3316400100032 (ERR-7,,,F) Atomic mass, Au 3316400100033 (ERR-8,,,F) Weight, 99Mo 3316400100034 (ERR-9,,,F) Weight, Au 3316400100035 (ERR-10,,,P) Detector Efficiency of detector, 99Mo 3316400100036 (ERR-11,,,P) Detector Efficiency of detector, Au 3316400100037 (ERR-12,,,F) Gamma abundances, Au 3316400100038 STATUS (TABLE) Text(p.355) Ind. J. Pure Appl. Phys. 58 (2020) 3316400100039 122236 3316400100040 HISTORY (20211103C) VT 3316400100041 (20220830U) VT. REFERENCE: IJP/A->IPA replaced 3316400100042 ENDBIB 40 0 3316400100043 NOCOMMON 0 0 3316400100044 ENDSUBENT 43 0 3316400199999 SUBENT 33164002 20220830 32083316400200001 BIB 2 3 3316400200002 REACTION (42-MO-100(N,2N)42-MO-99,,SIG) 3316400200003 DECAY-DATA ((1.)42-MO-99,65.97HR,DG,739.50,0.1220) 3316400200004 ((2.)42-MO-99,65.97HR,DG,181.06,0.0605) 3316400200005 ENDBIB 3 0 3316400200006 NOCOMMON 0 0 3316400200007 DATA 16 2 3316400200008 EN DATA ERR-T ERR-1 ERR-2 ERR-3 3316400200009 ERR-4 ERR-5 ERR-6 ERR-7 ERR-8 ERR-9 3316400200010 ERR-10 ERR-11 ERR-12 DECAY-FLAG 3316400200011 MEV B B B B B 3316400200012 B B B B B B 3316400200013 B B B NO-DIM 3316400200014 13.59 1.471 0.305 1.08E-02 12.95E-02 2.44E-023316400200015 13.57E-04 14.52E-04 3.99E-09 2.29E-08 5.20E-04 2.58E-043316400200016 4.18E-02 2.21E-02 5.14E-02 1. 3316400200017 13.59 1.471 0.305 1.20E-02 19.15E-02 2.74E-023316400200018 16.25E-04 16.25E-04 4.46E-09 2.56E-08 5.81E-04 2.89E-043316400200019 1.42E-02 2.48E-02 5.76E-02 2. 3316400200020 ENDDATA 12 0 3316400200021 ENDSUBENT 20 0 3316400299999 ENDENTRY 2 0 3316499999999