ENTRY 33156 20211201 32053315600000001 SUBENT 33156001 20211201 32053315600100001 BIB 11 34 3315600100002 TITLE Measurement of 90Zr(n,2n)89Zr and 90Zr(n,p)90mY 3315600100003 reaction cross-sections in the neutron energy range 3315600100004 of 10.95 to 20.02 MeV 3315600100005 AUTHOR (M.Mehta, N.L.Singh, R.K.Singh, S.Parashari, 3315600100006 P.V.Subhash, H.Naik, R.D.Chauhan, R.Makwana, 3315600100007 S.V.Suryanarayana, S.Mukherjee, A.Gandhi, J.Varmuza, 3315600100008 K.Katovsky) 3315600100009 INSTITUTE (3INDBDA,3INDTRM,3INDBHU) 3315600100010 (3INDIND) Institute for Plasma Research, Gandhinagar 3315600100011 (3INDIND) ITER-India, Gandhinagar 3315600100012 (3INDIND) Homi Bhabha National Institute, 3315600100013 Anushaktinagar, Mumbai 3315600100014 (3CZRCZR) Brno University of Technology, Czech Republic3315600100015 REFERENCE (J,JRN,328,71,2021) 3315600100016 FACILITY (VDGT,3INDTRM) 14 UD BARC-TIFR Pelletron facility 3315600100017 DETECTOR (HPGE) The gamma-ray counting of irradiated samples was3315600100018 performed using detector coupled with a PC-based 3315600100019 4096 channel analyzer. 3315600100020 The resolution of detector was 1.82 keV at 1332.50 keV 3315600100021 gamma-line of 60Co. 3315600100022 The dead time of detector was <5%. 3315600100023 INC-SOURCE (P-LI7) Natural lithium foil of thickness ~6.8 mg/cm2 3315600100024 was used as target, sandwich between two tantalum 3315600100025 foils of thickness ~4 mg/cm2 front side and 0.1 mm 3315600100026 in back side of Li to stop the proton beams. 3315600100027 The proton beam energies were 13, 16, 19 and 22 MeV. 3315600100028 METHOD (ACTIV) 3315600100029 ERR-ANALYS Some partial uncertainty are provided by author but 3315600100030 the units of uncertainties are not clear. 3315600100031 (DATA-ERR) Square-root of diagonal elements of 3315600100032 covariance matrix 3315600100033 STATUS (TABLE) Table 11+12 of J. Radioanal. Nucl. Chem. 328 3315600100034 (2021) 71 3315600100035 HISTORY (20211201C) VT 3315600100036 ENDBIB 34 0 3315600100037 NOCOMMON 0 0 3315600100038 ENDSUBENT 37 0 3315600199999 SUBENT 33156002 20211201 32053315600200001 BIB 5 11 3315600200002 REACTION (40-ZR-90(N,2N)40-ZR-89-G,M+,SIG,,SPA) 3315600200003 DECAY-DATA (40-ZR-89-G,78.41HR,DG,909.15,0.9904) 3315600200004 SAMPLE (40-ZR-90,NAT=0.5045) Natural Zr metal foil 3315600200005 (99.99% purity) 3315600200006 Al metal foil (purity 99.99%) with dimension of 3315600200007 10 x 10 mm2 and 0.1 mm thick have been used as monitor 3315600200008 to measure the neutron flux. 3315600200009 The samples were wrapped in a 0.025 mm thick 3315600200010 aluminum foil. 3315600200011 MONITOR (13-AL-27(N,A)11-NA-24,,SIG) 3315600200012 DECAY-MON (11-NA-24,14.997HR,DG,1368.63,0.999936) 3315600200013 ENDBIB 11 0 3315600200014 NOCOMMON 0 0 3315600200015 DATA 4 3 3315600200016 EN EN-RSL DATA DATA-ERR 3315600200017 MEV MEV MB MB 3315600200018 13.97 0.68 515.173 79.5072 3315600200019 16.99 0.53 1011.788 153.992 3315600200020 20.02 0.58 1091.078 178.243 3315600200021 ENDDATA 5 0 3315600200022 ENDSUBENT 21 0 3315600299999 SUBENT 33156003 20211201 32053315600300001 BIB 5 12 3315600300002 REACTION (40-ZR-90(N,P)39-Y-90-M,,SIG,,SPA) 3315600300003 DECAY-DATA (39-Y-90-M,3.19HR,DG,202.53,0.973, 3315600300004 DG,479.51,0.9074) 3315600300005 SAMPLE (40-ZR-90,NAT=0.5045) Natural Zr metal foil 3315600300006 (99.99% purity). 3315600300007 (49-IN-115,NAT=0.9571) In metal foil (purity 99.99%) 3315600300008 with dimension of 10 x 10 mm2 and 0.1 mm thick have 3315600300009 been used as monitor to measure the neutron flux. 3315600300010 The samples were wrapped in a 0.025 mm thick 3315600300011 aluminum foil. 3315600300012 MONITOR (49-IN-115(N,INL)49-IN-115-M,,SIG)) 3315600300013 DECAY-MON (49-IN-115-M,4.486HR,DG,336.24,0.460) 3315600300014 ENDBIB 12 0 3315600300015 NOCOMMON 0 0 3315600300016 DATA 4 4 3315600300017 EN EN-RSL DATA DATA-ERR 3315600300018 MEV MEV MB MB 3315600300019 10.95 0.45 5.897 1.014 3315600300020 13.97 0.68 8.854 2.140 3315600300021 16.99 0.53 12.232 3.069 3315600300022 20.02 0.58 7.452 1.922 3315600300023 ENDDATA 6 0 3315600300024 ENDSUBENT 23 0 3315600399999 ENDENTRY 3 0 3315699999999