ENTRY 31526 20030321 00003152600000001 SUBENT 31526001 20030321 00003152600100001 BIB 15 46 3152600100002 INSTITUTE (3CPRAEP) 3152600100003 REFERENCE (C,88MITO,,967,198805) 3152600100004 (J,CNP,7,(2),97,198505) Li Ze et al: referred to in 3152600100005 this work as to where information can be found how 3152600100006 fission yields were calculated from the measured data. 3152600100007 This includes information on ANALYSIS, CORRECTION and 3152600100008 ERR-ANALYS. See also EXFOR30751. 3152600100009 AUTHOR (Qi Linkun,Liu Conggui,Tang Peijia,Li Ze,Wang Xiuzhi, 3152600100010 Liu Yonghui,Liu Daming,Ju Changxin,Lu Huijun, 3152600100011 Zhi Jiaxuan,Guo Jingru) 3152600100012 TITLE Mass Distribution in Fission Spectrum Neutron Induced 3152600100013 Fission of U-235 3152600100014 COMMENT By compiler (ML): These measurements were performed 3152600100015 to test the radiochemical method used for fast fission 3152600100016 yield mesurements (see EXFOR31525), and are regarded 3152600100017 only as byproduct of the fast yield experiment. 3152600100018 However, it can be assumed, that the detector and 3152600100019 method are the same as for fast yields, although 3152600100020 no information on METHOD, DETECTOR or ANALYSIS is 3152600100021 explicitely given in the publication. 3152600100022 INC-SPECT Thermal neutron spectrum. 3152600100023 INC-SOURCE No information; compiler assumes: the thermal neutron 3152600100024 beam of the institute's heavy water reactor. 3152600100025 SAMPLE No information. 3152600100026 DETECTOR No information on fission counting or radioactivity 3152600100027 measurements. 3152600100028 From EXFOR31525 for beta-measurements: 3152600100029 (PROPC)-2Pi-gas-flow proportional counter, or 3152600100030 (SCIN)-2Pi-plastic-scintillator; 3152600100031 for gamma-measurements: 3152600100032 (NAICR)-well type NaI(Tl),3x3 inch, anticoincidence 3152600100033 spectrometer. 3152600100034 METHOD No information given. From EXFOR31525 for beta- 3152600100035 measurements: 3152600100036 (RCHEM) Sample was dissolved in 6-10M HCl, fission 3152600100037 products extracted with carriers;standard radiochemical3152600100038 procedures were used to separate and purify the fission3152600100039 product samples for measurement.Chemical yields were 3152600100040 determined. Purified samples were measured by beta- or 3152600100041 gamma-counting (generally for 2-4 half lives). 3152600100042 ANALYSIS No information, see second reference. 3152600100043 CORRECTION No information, see second reference. 3152600100044 ERR-ANALYS Only the overall error is given. 3152600100045 STATUS Data taken from text on page 970 of 88Mito. 3152600100046 HISTORY (20030129C) ML 3152600100047 (20030321U) OS. Ref.coding corrected 3152600100048 ENDBIB 46 0 3152600100049 COMMON 1 3 3152600100050 EN-DUMMY 3152600100051 EV 3152600100052 0.025 3152600100053 ENDCOMMON 3 0 3152600100054 ENDSUBENT 53 0 3152600199999 SUBENT 31526002 20030130 00003152600200001 BIB 2 2 3152600200002 REACTION (92-U-235(N,F)ELEM/MASS,CUM,FY,,MXW) 3152600200003 DECAY-DATA no information, see second reference. 3152600200004 ENDBIB 2 0 3152600200005 NOCOMMON 0 0 3152600200006 DATA 4 3 3152600200007 MASS ELEMENT DATA ERR-T 3152600200008 NO-DIM NO-DIM PC/FIS PC/FIS 3152600200009 95. 40. 6.39 0.21 3152600200010 99. 42. 6.08 0.16 3152600200011 144. 58. 5.34 0.34 3152600200012 ENDDATA 5 0 3152600200013 ENDSUBENT 12 0 3152600299999 ENDENTRY 2 0 3152699999999