ENTRY 23723 20210206 22982372300000001 SUBENT 23723001 20210206 22982372300100001 BIB 13 42 2372300100002 TITLE The cross-sections for the 187Re(n,p)187W and 2372300100003 185Re(n,3n)183Re reactions in the energy range between 2372300100004 13.08 MeV and 19.50 MeV 2372300100005 AUTHOR (S.Ilic,N.Jovancevic,L.Daraban,H.Stroh,S.Oberstedt, 2372300100006 M.Hult,C.Bonaldi,W.Geerts,F.-J.Hambsch,G.Lutter, 2372300100007 G.Marissens,M.Vidali,D.Knezevic) 2372300100008 INSTITUTE (3SRBSRB) University of Novi Sad, Trg Dositeja 2372300100009 Obradovica 6, 21000 Novi Sad, Serbia 2372300100010 (3RUMRUM) University Babes-Bolyai, Str. M. Kogalniceanu2372300100011 No.1, 400084 Cluj Napoca, Romania 2372300100012 (2ZZZGEL) 2372300100013 (3SRBSRB) Institute of Physics Belgrade, 2372300100014 Pregrevica 118, 11080 Belgrade, Serbia 2372300100015 REFERENCE (J,EPJ/A,56,202,2020) 2372300100016 #doi:10.1140/epja/s10050-020-00207-8 2372300100017 (J,EPJ/CS,146,11025,2017) preliminary data 2372300100018 REL-REF (M,23301001,N.Jovancevic+,J,EPJ/A,52,148,2016) 2372300100019 Irradiation and analysis procedure 2372300100020 FACILITY (VDG,2ZZZGEL) 2372300100021 INC-SOURCE (D-T) Ti-3H target of 2.293 mg/cm2 with the 3H/Ti 2372300100022 ratio of 1.4 at the start of the irradiation. 2372300100023 Deuterium ion beam energy was 2.000(11) MeV. 2372300100024 METHOD (ACTIV,GSPEC) First gamma-ray spectra measurement 2372300100025 was perform 20 min after irradiation. The second one 2372300100026 was carried out after a period of time significantly 2372300100027 greater than the half-live of the short-living 2372300100028 radionuclides, such as 184Re and 186Re. 2372300100029 DETECTOR (IOCH,IOCH) Measurements of the neutron fluence were 2372300100030 done with two ionization chambers, one loaded with 2372300100031 235U and another one with 238U. The chamber with 238U 2372300100032 target was used for the determination of the neutron 2372300100033 fluence rate, and the 235U chamber was used as a 2372300100034 neutron flux monitor. 2372300100035 (HPGE) 2372300100036 - coaxial HPGe-detector with a 40% relative efficiency 2372300100037 - BEGe with 50% relative efficiency 2372300100038 SAMPLE Rhenium disks (20 mm in diameter and 5 mm in 2372300100039 thickness) of natural isotopic abundance with a 2372300100040 stated relative purity of 99.9%. 2372300100041 ERR-ANALYS (DATA-ERR) No information on sources of uncertainties. 2372300100042 STATUS (APRVD) Approved by S.Ilie (08.03.2021) 2372300100043 HISTORY (20210206C) VS 2372300100044 ENDBIB 42 0 2372300100045 NOCOMMON 0 0 2372300100046 ENDSUBENT 45 0 2372300199999 SUBENT 23723002 20210206 22982372300200001 BIB 5 12 2372300200002 REACTION 1(75-RE-185(N,3N)75-RE-183,,SIG) 2372300200003 2(75-RE-185(N,3N)75-RE-183,,SIG) 2372300200004 DECAY-DATA (75-RE-183-G,,DG,162.3,0.25) 2372300200005 INC-SPECT 1Disk no. 4 was kept in steady position at 0 degrees and2372300200006 irradiated by neutrons with an energy of 18.1 MeV 2372300200007 2Disks were activated by effective wide energy neutron 2372300200008 field by moving along a circular arc extending from 2372300200009 0 to 80 degrees and located 200 mm from the tritium 2372300200010 target 2372300200011 ANALYSIS 2(UNFLD) Two types of algorithms for unfolding 2372300200012 procedures were used in this work, MAXED and GRAVEL. 2372300200013 STATUS (TABLE) Tbls. 3 and 4 of Eur.Phys.J.A 56(2020)202 2372300200014 ENDBIB 12 0 2372300200015 NOCOMMON 0 0 2372300200016 DATA 6 7 2372300200017 EN EN-ERR DATA 1DATA-ERR 1DATA 2DATA-ERR 22372300200018 MEV MEV B B B B 2372300200019 18.3 1.2 0.83 0.042372300200020 18.1 0.28 0.834 0.034 2372300200021 17.3 1.0 0.32 0.022372300200022 16.8 0.9 0.41 0.022372300200023 16.1 0.6 0.32 0.022372300200024 15.3 0.6 0.126 0.0072372300200025 14.8 0.5 0.066 0.0032372300200026 ENDDATA 9 0 2372300200027 ENDSUBENT 26 0 2372300299999 SUBENT 23723003 20210206 22982372300300001 BIB 5 12 2372300300002 REACTION 1(75-RE-187(N,P)74-W-187,,SIG) 2372300300003 2(75-RE-187(N,P)74-W-187,,SIG) 2372300300004 DECAY-DATA (74-W-187,,DG,618.3,0.076) 2372300300005 INC-SPECT 1Disk no. 4 was kept in steady position at 0 degrees and2372300300006 irradiated by neutrons with an energy of 18.1 MeV 2372300300007 2Disks were activated by effective wide energy neutron 2372300300008 field by moving along a circular arc extending from 2372300300009 0 to 80 degrees and located 200 mm from the tritium 2372300300010 target 2372300300011 ANALYSIS 2(UNFLD) Two types of algorithms for unfolding 2372300300012 procedures were used in this work, MAXED and GRAVEL. 2372300300013 STATUS (TABLE) Table 3 of Eur.Phys.J.A 56(2020)202 2372300300014 ENDBIB 12 0 2372300300015 NOCOMMON 0 0 2372300300016 DATA 6 7 2372300300017 EN EN-ERR DATA 1DATA-ERR 1DATA 2DATA-ERR 22372300300018 MEV MEV B B B B 2372300300019 18.3 1.2 0.0049 0.00032372300300020 18.1 0.28 0.0049 0.0012 2372300300021 17.3 1.0 0.0037 0.00022372300300022 16.8 0.9 0.0054 0.00032372300300023 16.1 0.6 0.0052 0.00032372300300024 15.3 0.6 0.0031 0.00022372300300025 14.8 0.5 0.0023 0.00032372300300026 ENDDATA 9 0 2372300300027 ENDSUBENT 26 0 2372300399999 ENDENTRY 3 0 2372399999999