ENTRY 22323 19970214 00002232300000001 SUBENT 22323001 19970214 00002232300100001 BIB 15 34 2232300100002 REFERENCE (C,94GATLIN,,1045,9405) MAIN REF. 2232300100003 TITLE -CROSS SECTION MEASUREMENTS FOR STUDIES ON NUCLEAR 2232300100004 TRANSMUTATION AND NUCLEOSYNTHESIS. 2232300100005 AUTHOR (M.IGASHIRA,K.MASUDA,Y.NAGAI,H.KITAZAWA) 2232300100006 INSTITUTE (2JPNTIT) 2232300100007 FACILITY (VDG) THE 3-MV PELLETRON ACCELERATOR OF THE RESEARCH 2232300100008 LABORATORY FOR NUCLEAR REACTORS AT THE TOKYO 2232300100009 INSTITUTE OF TECHNOLOGY. 2232300100010 INC-SOURCE (P-LI7) 2232300100011 INC-SPECT .MONOENERGETIC NEUTRONS PRODUCED IN THE LI-7(P,N) 2232300100012 REACTION. 2232300100013 METHOD (GSPEC) CAPTURE GAMMA RAYS WERE DETECTED AT 125 2232300100014 DEGREES WITH A NAI(TL) CRYSTAL DETECTOR. 2232300100015 DETECTOR (NAICR) THE MAIN DETECTOR IS 15.2 CM IN DIAMETER 2232300100016 AND 20.3 CM LONG. IT IS SURROUNDED BY A HOLLOW 2232300100017 ANTICOMPTON SHIELD, 33.0 CM IN DIAMETER AND 35.6 2232300100018 CM LONG. 2232300100019 (SCIN) RELATIVE MONITORING WAS ACHIEVED USING A 2232300100020 LI-6 GLASS SCINTILLATION COUNTER. 2232300100021 PART-DET (G ) 2232300100022 SAMPLE .THE SAMPLES WERE DISKS WITH A DIAMETER OF 9 OR 2 2232300100023 CM, WITH THICKNESSES OF 0.2 TO 3.0 CM. THESE WERE 2232300100024 LOCATED 15.6 OR 11.8 CM FROM THE NEUTRON SOURCE 2232300100025 AT AN ANGLE OF ZERO DEGREES WITH RESPECT TO THE 2232300100026 INCOMING PROTON BEAM. 2232300100027 CORRECTION .CORRECTIONS WERE MADE FOR MULTIPLE SCATTERING 2232300100028 OF NEUTRONS AND GAMMA ABSORPTION IN THE SAMPLE, 2232300100029 AND FOR THE DEPENDENCE OF THE GAMMA-RAY DETECTION 2232300100030 EFFICIENCY ON THE GAMMA-RAY SOURCE POSITION IN 2232300100031 THE SAMPLE. 2232300100032 ERR-ANALYS (DATA-ERR) 2232300100033 STATUS .TAKEN FROM MAIN REFERENCE. 2232300100034 HISTORY (960914C) J.B. 2232300100035 (970214E) 2232300100036 ENDBIB 34 0 2232300100037 NOCOMMON 0 0 2232300100038 ENDSUBENT 37 0 2232300199999 SUBENT 22323002 19970214 00002232300200001 BIB 3 4 2232300200002 REACTION (5-B-10(N,G)5-B-11,PAR,SIG) 2232300200003 STATUS .TAKEN FROM MAIN REFERENCE. 2232300200004 HISTORY (960925C) J.B. 2232300200005 (970214E) 2232300200006 ENDBIB 4 0 2232300200007 COMMON 1 3 2232300200008 EN 2232300200009 KEV 2232300200010 4.0000E+01 2232300200011 ENDCOMMON 3 0 2232300200012 DATA 3 4 2232300200013 E-EXC DATA DATA-ERR 2232300200014 MEV MB MB 2232300200015 0.0000E+00 1.1400E-02 1.9000E-03 2232300200016 4.4500E+00 1.6170E-01 1.2500E-02 2232300200017 6.7400E+00 8.3100E-02 1.0100E-02 2232300200018 8.9200E+00 3.1500E-02 5.1000E-03 2232300200019 ENDDATA 6 0 2232300200020 ENDSUBENT 19 0 2232300299999 SUBENT 22323003 19970214 00002232300300001 BIB 3 4 2232300300002 REACTION (5-B-11(N,G)5-B-12,PAR,SIG) 2232300300003 STATUS .TAKEN FROM MAIN REFERENCE. 2232300300004 HISTORY (960925C) J.B. 2232300300005 (970214E) 2232300300006 ENDBIB 4 0 2232300300007 NOCOMMON 0 0 2232300300008 DATA 4 6 2232300300009 EN E-EXC DATA DATA-ERR 2232300300010 KEV MEV MB MB 2232300300011 2.3000E+01 0.0000E+00 9.5000E-03 3.2000E-03 2232300300012 2.3000E+01 1.6700E+00 2.2840E-01 1.2300E-02 2232300300013 4.0000E+01 0.0000E+00 5.1000E-03 9.0000E-04 2232300300014 4.0000E+01 1.6700E+00 1.4600E-02 1.2000E-03 2232300300015 6.1000E+01 0.0000E+00 5.9000E-03 1.4000E-03 2232300300016 6.1000E+01 1.6700E+00 1.1900E-02 2.4000E-03 2232300300017 ENDDATA 8 0 2232300300018 ENDSUBENT 17 0 2232300399999 ENDENTRY 3 0 2232399999999