ENTRY 14198 20090505 13531419800000001 SUBENT 14198001 20090505 13531419800100001 BIB 11 18 1419800100002 TITLE Spin of the 3120 keV level in 56Fe 1419800100003 AUTHOR (V.C.Rogers) 1419800100004 INSTITUTE (1USABYU) 1419800100005 REFERENCE (J,PR/C,6,801,1972) 1419800100006 FACILITY (LINAC,1USAGRT) Gulf Radiation Technology linac 1419800100007 SAMPLE Ring shaped natural iron sample with inner radius of 1419800100008 14.0cm, outer radius of 24.1 cm and thickness of 1419800100009 0.95 cm 1419800100010 DETECTOR (GELI) 80cm3 Ge(Li) detector positioned at 125 deg 1419800100011 with respect to the incident neutron beam 1419800100012 METHOD (TOF) Time of flight was used to determine incident 1419800100013 neutron energy 1419800100014 INC-SOURCE (PHOTO) 1419800100015 ERR-ANALYS (DATA-ERR)Quoted absolute uncertainties include 1419800100016 statistical and systematic uncertainties. 1419800100017 (ERR-1) Systematic uncertainty in production of 1419800100018 847 keV gamma ray. 1419800100019 HISTORY (20081231C) 1419800100020 ENDBIB 18 0 1419800100021 COMMON 1 3 1419800100022 ERR-1 1419800100023 PER-CENT 1419800100024 8.0 1419800100025 ENDCOMMON 3 0 1419800100026 ENDSUBENT 25 0 1419800199999 SUBENT 14198002 20090505 13531419800200001 BIB 4 5 1419800200002 REACTION (26-FE-56(N,INL)26-FE-56,PAR,SIG) 1419800200003 STATUS (CURVE) Data taken from fig. 2 of the reference 1419800200004 MONITOR (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) Cross section for 1419800200005 production of 847 keV gamma ray was used as monitor 1419800200006 MONIT-REF (14198003,V.C.Rogers,J,PR/C,6,801,1972) 1419800200007 ENDBIB 5 0 1419800200008 COMMON 1 3 1419800200009 E-LVL 1419800200010 KEV 1419800200011 3120.0 1419800200012 ENDCOMMON 3 0 1419800200013 DATA 3 4 1419800200014 EN DATA DATA-ERR 1419800200015 MEV MB MB 1419800200016 3.678E+00 5.505E+01 6.654E+00 1419800200017 4.551E+00 5.315E+01 7.166E+00 1419800200018 4.898E+00 4.819E+01 6.652E+00 1419800200019 5.588E+00 3.265E+01 6.913E+00 1419800200020 ENDDATA 6 0 1419800200021 ENDSUBENT 20 0 1419800299999 SUBENT 14198003 20090505 13531419800300001 BIB 2 2 1419800300002 REACTION (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) 1419800300003 STATUS (CURVE) Data taken from fig. 3 of the reference 1419800300004 ENDBIB 2 0 1419800300005 COMMON 1 3 1419800300006 E 1419800300007 KEV 1419800300008 847.0 1419800300009 ENDCOMMON 3 0 1419800300010 DATA 3 11 1419800300011 EN DATA DATA-ERR 1419800300012 MEV MB MB 1419800300013 8.996E-01 4.752E+02 5.557E+01 1419800300014 1.157E+00 6.014E+02 6.297E+01 1419800300015 1.506E+00 7.833E+02 7.779E+01 1419800300016 1.910E+00 8.579E+02 8.888E+01 1419800300017 2.324E+00 1.066E+03 9.259E+01 1419800300018 2.803E+00 1.044E+03 9.627E+01 1419800300019 3.300E+00 1.134E+03 1.037E+02 1419800300020 3.816E+00 1.197E+03 1.149E+02 1419800300021 4.351E+00 1.094E+03 1.037E+02 1419800300022 4.885E+00 1.128E+03 1.111E+02 1419800300023 5.373E+00 1.207E+03 1.111E+02 1419800300024 ENDDATA 13 0 1419800300025 ENDSUBENT 24 0 1419800399999 SUBENT 14198004 20090505 13531419800400001 BIB 4 5 1419800400002 REACTION (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) 1419800400003 STATUS (CURVE) Data taken from fig. 3 of the reference 1419800400004 MONITOR (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) Cross section for 1419800400005 production of 847 keV gamma ray was used as monitor 1419800400006 MONIT-REF (14198003,V.C.Rogers,J,PR/C,6,801,1972) 1419800400007 ENDBIB 5 0 1419800400008 COMMON 1 3 1419800400009 E 1419800400010 KEV 1419800400011 1811.0 1419800400012 ENDCOMMON 3 0 1419800400013 DATA 3 6 1419800400014 EN DATA DATA-ERR 1419800400015 MEV MB MB 1419800400016 2.819E+00 1.275E+02 1.402E+01 1419800400017 3.398E+00 1.427E+02 1.495E+01 1419800400018 3.859E+00 1.401E+02 1.309E+01 1419800400019 4.384E+00 1.217E+02 1.402E+01 1419800400020 4.936E+00 1.294E+02 1.869E+01 1419800400021 5.415E+00 1.213E+02 1.403E+01 1419800400022 ENDDATA 8 0 1419800400023 ENDSUBENT 22 0 1419800499999 SUBENT 14198005 20090505 13531419800500001 BIB 4 5 1419800500002 REACTION (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) 1419800500003 STATUS (CURVE) Data taken from fig. 3 of the reference 1419800500004 MONITOR (26-FE-56(N,INL)26-FE-56,PAR,SIG,G) Cross section for 1419800500005 production of 847 keV gamma ray was used as monitor 1419800500006 MONIT-REF (14198003,V.C.Rogers,J,PR/C,6,801,1972) 1419800500007 ENDBIB 5 0 1419800500008 COMMON 1 3 1419800500009 E 1419800500010 KEV 1419800500011 1238.0 1419800500012 ENDCOMMON 3 0 1419800500013 DATA 3 7 1419800500014 EN DATA DATA-ERR 1419800500015 MEV MB MB 1419800500016 2.360E+00 3.951E+01 1.387E+01 1419800500017 2.836E+00 1.275E+02 1.295E+01 1419800500018 3.379E+00 1.508E+02 1.757E+01 1419800500019 3.848E+00 1.999E+02 1.942E+01 1419800500020 4.372E+00 2.426E+02 2.127E+01 1419800500021 4.933E+00 2.752E+02 2.959E+01 1419800500022 5.421E+00 3.003E+02 2.959E+01 1419800500023 ENDDATA 9 0 1419800500024 ENDSUBENT 23 0 1419800599999 ENDENTRY 5 0 1419899999999