ENTRY            13491   19910614                             00001349100000001 
SUBENT        13491001   19910614                             00001349100100001 
BIB                 11         13                                 1349100100002 
INSTITUTE  (1USAPUR)                                              1349100100003 
REFERENCE  (J,NIM/B,51,198,9008)                                  1349100100004 
AUTHOR     (B.R.BULLARD,J.G.MULLEN)                               1349100100005 
TITLE      BURNOUT CROSS SECTION OF 159DY                         1349100100006 
FACILITY   (REAC,1USAMIS). MURR                                   1349100100007 
INC-SOURCE THERMAL FLUX OF ABOUT 2.5E14 N/CM**2/SEC               1349100100008 
SAMPLE     THREE SAMPLES OF DY-O(2) IN THE FORM OF A FINE POWDER. 1349100100009 
           ENRICHED TO 20.8 ATOM% 158DY                           1349100100010 
DETECTOR   (GE-IN)                                                1349100100011 
STATUS     (APRVD) B.R.BULLARD, 91/6/14                           1349100100012 
ERR-ANALYS AUTHOR'S ESTIMATE BURNOUT CROSS SECTION TO BE 8000+-   1349100100013 
            2000 B.                                               1349100100014 
HISTORY    (910523C)                                              1349100100015 
ENDBIB              13          0                                 1349100100016 
COMMON               1          3                                 1349100100017 
EN-DUMMY                                                          1349100100018 
EV                                                                1349100100019 
 0.0253                                                           1349100100020 
ENDCOMMON            3          0                                 1349100100021 
ENDSUBENT           20          0                                 1349100199999 
SUBENT        13491002   19910523                             00001349100200001 
BIB                  4          5                                 1349100200002 
REACTION   (66-DY-159(N,ABS),,SIG,,MXW) BURNOUT CROSS SECTION     1349100200003 
MONITOR    ((MONIT1)66-DY-158(N,G)66-DY-159,,SIG,,MXW)            1349100200004 
           ((MONIT2)66-DY-158(N,G)66-DY-159,,RI)                  1349100200005 
DECAY-MON  (66-DY-159,,DG,58.,0.0222)                             1349100200006 
CORRECTION CORRECTED FOR ATTENUATION, INCLUDING SELF-ATTENUATION. 1349100200007 
ENDBIB               5          0                                 1349100200008 
NOCOMMON             0          0                                 1349100200009 
DATA                 3          1                                 1349100200010 
DATA       MONIT1     MONIT2                                      1349100200011 
B          B          B                                           1349100200012 
7100.        43.       120.                                       1349100200013 
ENDDATA              3          0                                 1349100200014 
ENDSUBENT           13          0                                 1349100299999 
SUBENT        13491003   19910523                             00001349100300001 
BIB                  5          9                                 1349100300002 
REACTION   (66-DY-159(N,ABS),,SIG,,MXW) BURNOUT CROSS SECTION     1349100300003 
MONITOR    ((MONIT)66-DY-166(N,ABS),,SIG,,MXW) BURNOUT CROSS      1349100300004 
              SECTION                                             1349100300005 
DECAY-MON  (66-DY-166,,DG,82.)                                    1349100300006 
DECAY-DATA (66-DY-159,,DG,58.)                                    1349100300007 
CORRECTION CORRECTED FOR:                                         1349100300008 
            -SELF ABSORPTION IN SOURCE                            1349100300009 
            -DECAY SINCE IRRADIATION                              1349100300010 
            -ATTENUATION BY MATERIALS IN BEAM PATH                1349100300011 
ENDBIB               9          0                                 1349100300012 
NOCOMMON             0          0                                 1349100300013 
DATA                 2          1                                 1349100300014 
DATA       MONIT                                                  1349100300015 
B          B                                                      1349100300016 
9100.       100.                                                  1349100300017 
ENDDATA              3          0                                 1349100300018 
ENDSUBENT           17          0                                 1349100399999 
ENDENTRY             3          0                                 1349199999999