ENTRY E2504 20170125 E106E250400000001 SUBENT E2504001 20170125 E106E250400100001 BIB 11 31 E250400100002 TITLE Mapping the deformation in the ''island of E250400100003 inversion'': Inelastic scattering of 30Ne and 36Mg at E250400100004 intermediate energies E250400100005 AUTHOR (P.Doornenbal, H.Scheit, S.Takeuchi, N.Aoi, K.Li, E250400100006 M.Matsushita, D.Steppenbeck, H.Wang, H.Baba, E250400100007 E.Ideguchi, N.Kobayashi, Y.Kondo, J.Lee, S.Michimasa, E250400100008 T.Motobayashi, A.Poves, H.Sakurai, M.Takechi, E250400100009 Y.Togano, K.Yoneda) E250400100010 INSTITUTE (2JPNIPC) RIKEN Nishina Center E250400100011 (3CPRBJG) E250400100012 (2JPNYOK) Department of Physics E250400100013 (2JPNTOK) Center for Nuclear Study E250400100014 (2JPNTIT) Department of Physics E250400100015 (2SPNAUT) Departamento de Fisica Teorica and E250400100016 IFT-UAM/CSIC E250400100017 REFERENCE (J,PR/C,93,044306,2016) E250400100018 SAMPLE - Chemical-form of target is element. E250400100019 - Physical-form of target is solid. E250400100020 METHOD (EDE,TOF,GSPEC) E250400100021 FACILITY (CYCLO,2JPNIPC) To accelerate primary 345 MeV/nucleon E250400100022 48Ca beam E250400100023 (PRJFS,2JPNIPC) 30Ne and 36Mg beams were produced from E250400100024 Be production target E250400100025 DETECTOR (NAICR) DALI2 NaI(Tl) based gamma-ray spectrometer E250400100026 (MAGSP,PPAC) ZeroDegree Spectrometer E250400100027 CORRECTION Feeding of 6+/-6% was assumed, and subtracted from the E250400100028 observed cross sections E250400100029 ERR-ANALYS (DATA-ERR) Quoted errors include the fit errors and E250400100030 the error for the absolute efficiency of E250400100031 DALI2. E250400100032 HISTORY (20160530C) Ichko E250400100033 ENDBIB 31 0 E250400100034 NOCOMMON 0 0 E250400100035 ENDSUBENT 34 0 E250400199999 SUBENT E2504002 20170125 E106E250400200001 BIB 8 9 E250400200002 REACTION (6-C-0(10-NE-30,INL)6-C-0,PAR,SIG) E250400200003 PART-DET (G,10-NE-30) E250400200004 EN-SEC (E-LVL,10-NE-30) E250400200005 LEVEL-PROP (10-NE-30,E-LVL=0.799,SPIN=2.,PARITY=+1.) E250400200006 INC-SOURCE Beam intensity is 370 PPS. E250400200007 SAMPLE Target-thickness is 2540 mg/cm2. E250400200008 METHOD (COINC) Detect prompt gamma and 30Ne in coincidence. E250400200009 STATUS (TABLE) Presented in Table 1 of Phys. Rev. C 93, E250400200010 044306, 2016 E250400200011 ENDBIB 9 0 E250400200012 COMMON 3 3 E250400200013 EN E-LVL E-LVL-ERR E250400200014 MEV/A KEV KEV E250400200015 228. 799. 5. E250400200016 ENDCOMMON 3 0 E250400200017 DATA 2 1 E250400200018 DATA DATA-ERR E250400200019 MB MB E250400200020 14.4 0.14 E250400200021 ENDDATA 3 0 E250400200022 ENDSUBENT 21 0 E250400299999 SUBENT E2504003 20170125 E106E250400300001 BIB 8 9 E250400300002 REACTION (82-PB-0(10-NE-30,INL)82-PB-0,PAR,SIG) E250400300003 PART-DET (G,10-NE-30) E250400300004 EN-SEC (E-LVL,10-NE-30) E250400300005 LEVEL-PROP (10-NE-30,E-LVL=0.801,SPIN=2.,PARITY=+1.) E250400300006 INC-SOURCE Beam intensity is 370 PPS. E250400300007 SAMPLE Target-thickness is 3370 mg/cm2. E250400300008 METHOD (COINC) Detect prompt gamma and 30Ne in coincidence. E250400300009 STATUS (TABLE) Presented in Table 1 of Phys. Rev. C 93, E250400300010 044306, 2016 E250400300011 ENDBIB 9 0 E250400300012 COMMON 3 3 E250400300013 EN E-LVL E-LVL-ERR E250400300014 MEV/A KEV KEV E250400300015 232. 801. 6. E250400300016 ENDCOMMON 3 0 E250400300017 DATA 2 1 E250400300018 DATA DATA-ERR E250400300019 MB MB E250400300020 56. 6. E250400300021 ENDDATA 3 0 E250400300022 ENDSUBENT 21 0 E250400399999 SUBENT E2504004 20170125 E106E250400400001 BIB 8 9 E250400400002 REACTION (6-C-0(12-MG-36,INL)6-C-0,PAR,SIG) E250400400003 PART-DET (G,12-MG-36) E250400400004 EN-SEC (E-LVL,12-MG-36) E250400400005 LEVEL-PROP (12-MG-36,E-LVL=0.666,SPIN=2.,PARITY=+1.) E250400400006 INC-SOURCE Beam intensity is 95 PPS. E250400400007 SAMPLE Target-thickness is 2540 mg/cm2. E250400400008 METHOD (COINC) Detect prompt gamma and 36Mg in coincidence. E250400400009 STATUS (TABLE) Presented in Table 1 of Phys. Rev. C 93, E250400400010 044306, 2016 E250400400011 ENDBIB 9 0 E250400400012 COMMON 3 3 E250400400013 EN E-LVL E-LVL-ERR E250400400014 MEV/A KEV KEV E250400400015 218. 666. 5. E250400400016 ENDCOMMON 3 0 E250400400017 DATA 2 1 E250400400018 DATA DATA-ERR E250400400019 MB MB E250400400020 15.1 0.16 E250400400021 ENDDATA 3 0 E250400400022 ENDSUBENT 21 0 E250400499999 SUBENT E2504005 20170125 E106E250400500001 BIB 8 9 E250400500002 REACTION (82-PB-0(12-MG-36,INL)82-PB-0,PAR,SIG) E250400500003 PART-DET (G,12-MG-36) E250400500004 EN-SEC (E-LVL,12-MG-36) E250400500005 LEVEL-PROP (12-MG-36,E-LVL=0.665,SPIN=2.,PARITY=+1.) E250400500006 INC-SOURCE Beam intensity is 95 PPS. E250400500007 SAMPLE Target-thickness is 3370 mg/cm2. E250400500008 METHOD (COINC) Detect prompt gamma and 36Mg in coincidence. E250400500009 STATUS (TABLE) Presented in Table 1 of Phys. Rev. C 93, E250400500010 044306, 2016 E250400500011 ENDBIB 9 0 E250400500012 COMMON 3 3 E250400500013 EN E-LVL E-LVL-ERR E250400500014 MEV/A KEV KEV E250400500015 223. 665. 5. E250400500016 ENDCOMMON 3 0 E250400500017 DATA 2 1 E250400500018 DATA DATA-ERR E250400500019 MB MB E250400500020 72. 8. E250400500021 ENDDATA 3 0 E250400500022 ENDSUBENT 21 0 E250400599999 ENDENTRY 5 0 E250499999999