/* NRDF D1769 Data No.97 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,97;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,97;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(40AR,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1340MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'301';
/* '301' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,97;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'302';
/* '302' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'303'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 51.6 +-16.1
6 70.4 +-12.9
7 46.9 +-12.3
8 28.1 +-11.7
9 37.5 +-10.1
10 56.3 +-8.2
20 16.9 +-2.4
40 14.1 +-2.0
60 16.2 +-1.8
80 14.5 +-1.7
100 12.9 +-1.6
120 12.0 +-1.5
140 9.62 +-1.38
160 8.21 +-1.10
180 6.33 +-1.14
200 5.63 +-1.16
230 4.53 +-0.82
260 3.28 +-0.63
290 1.88 +-0.49
320 1.25 +-0.53
360 0.469 +-0.469
400 1.06 +-0.35
460 0.704 +-0.254
520 0.313 +-0.213
600 0.176 +-0.154
720 0.117 +-0.110
880 0.117 +-0.076
1080 0.117 +-0.042
1280 4.69e-02 +-2.78e-02
1480 2.35e-02 +-4.11e-02
1680 -4.69e-02 +-5.21e-02
1880 0.00e+00 +-2.73e-02
\END;
/*===================================================================*/
|