|
| /*===================================================================*/
/* NRDF D1769 Data No.96 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,96;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,96;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(40AR,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1340MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'298';
/* '298' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,96;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'299';
/* '299' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'300'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 61.0 +-26.3
6 79.3 +-19.3
7 61.0 +-19.4
8 67.1 +-16.8
9 48.8 +-18.4
10 36.6 +-15.7
20 24.1 +-3.5
40 18.9 +-3.7
60 20.4 +-3.5
80 22.9 +-3.7
100 28.1 +-3.4
120 19.2 +-3.3
140 20.1 +-3.1
160 22.0 +-2.9
180 15.9 +-2.6
200 18.0 +-2.6
230 16.1 +-2.0
260 11.6 +-1.6
290 6.71 +-1.47
320 7.32 +-1.20
360 5.03 +-1.02
400 2.59 +-0.83
460 3.36 +-0.52
520 0.813 +-0.389
600 1.07 +-0.35
720 5.08e-02 +-1.90e-01
880 0.381 +-0.123
1080 6.10e-02 +-8.90e-02
1280 0.00e+00 +-8.29e-02
1480 3.05e-02 +-6.09e-02
1680 0.00e+00 +-5.95e-02
1880 0.00e+00 +-3.94e-02
\END;
/*===================================================================*/
|