/* NRDF D1769 Data No.93 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,93;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,93;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=CU(40AR,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1340MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'289';
/* '289' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,93;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=2.5%'290';
/* '290' Uncertainty in target thickness */
THTL=10DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'291'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
10 56.8 +-69.1
20 31.7 +-7.9
50 36.3 +-7.1
80 39.2 +-8.0
110 36.3 +-8.5
140 74.5 +-9.7
170 102 +-14
200 129 +-16
230 196 +-16
260 242 +-16
290 232 +-14
320 202 +-12
360 205 +-10
400 144 +-7
460 111 +-4
520 52.1 +-2.8
600 30.3 +-1.8
720 12.0 +-0.9
880 3.55 +-0.42
1080 0.758 +-0.192
1280 0.237 +-0.121
1480 0.284 +-0.095
1680 0.189 +-0.076
1880 9.47e-02 +-5.79e-02
\END;
/*===================================================================*/
|