/* NRDF D1306 Data No.9 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,9;
D#=D1306;
TITLE=/ Isomeric yield ratios in proton-, 3He-, and
alpha-particle-induced reactions on 197Au /;
ATH=(Y.NAGAME'1', K.SUEKI'2', S.BABA'1', H.NAKAHARA'2');
INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
/* '1' Department of Radioisotopes */
/* '2' Department of Chemistry, Faculty of Science */
REF=PR/C;
VLP=41(1990)889;
RCTS=(197AU(P,3*N)195HG, 197AU(3HE,4*N)196TL, 197AU(ALPHA,3*N)198TL,
197AU(3HE,2*P)198AU, 197AU(P,N,P)196AU, 197AU(3HE,ALPHA)196AU,
197AU(ALPHA,N,ALPHA)196AU);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,9;
/* 2006-10-19 : Converted, N.Otuka. Converted to EXFOR E1306 */
/* Related references
- C.F.Williamson et al., CEA-R-, 3042(1966).
(Range-energy data)
- H.L.Smith, LA-, 1721(1975).
(Chemical separation method)
- W.W.Bowman et al., AND, 13(1974)89.
Reference from which data were used (Decay data used in cross
section evaluation)
- C.M.Lederer et al., LEDERER-7, (1978).
Reference from which data were used (Decay data used in cross
section evaluation)
PHQ=XSECTN;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=5[10MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
BEAM-INTNSTY=[0.5UA;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=GE(LI)'3';
/* '3' To measure gamma rays */
ANL=STATIST-MODEL'4';
/* '4' Hauser-Feshbach model */
/* Experimental Method:
- Stacked target irradiation
- Gamma ray spectrometry
/* 2007-01-06 : Altered, Mh. Re-digitized */
RCT=197AU(P,N,P)196AU;
ACC=CYC;
INST-ACC=2JPNINS;
DET-PARTCL=GAMMA'26';
/* '26' Delayed gamma from 196Au (metastable state)Jpi=12- */
/* Experimental Method:
- Chemical separation
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,9;
TOT-ERR=20%'5';
/* '5' Maximum total uncertainty (10-20%) */
SYS-ERR=(2%'6',3%'7',10%'8');
/* '6' Uncertainty in current integration */
/* '7' Uncertainty in detector efficiency */
/* '8' Uncertainty in chemical yield */
STATIST-ERR=15%'9';
/* '9' Maximum uncertainty in gamma-ray peak analysis (5-15%) */
ENGY-GAMMA=147.8KEV'27';
INTNSTY-GAMMA=0.446'27';
HALF-LIFE=9.7HOUR'27';
/* '27' Delayed gamma from 196Au (metastable state) (Jpi=12-) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA
(MEV) (MB)
2.047E+01 3.680E+00
2.531E+01 3.021E+01
2.638E+01 4.442E+01
2.845E+01 8.133E+01
2.946E+01 6.454E+01
3.065E+01 1.114E+02
3.448E+01 1.050E+02
3.806E+01 1.056E+02
4.138E+01 1.114E+02
4.333E+01 9.322E+01
4.433E+01 1.019E+02
4.747E+01 1.094E+02
4.911E+01 1.134E+02
\END;
/*===================================================================*/
|