/* NRDF D0815 Data No.9 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,9;
D#=D815;
TITLE=/Analyzing power of the neutron continuum spectrum for the
93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
PURPOSE=/To provide stringent test for various theories by simultaneous
fitting of analyzing powers as well as cross sections for both
neutron and proton spectra/;
ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
/* '2' Department of Physics */
REF=PL/B;
VLP=133(1983)375;
RCTS=93NB(P,N)X;
PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
/* '3' Double differential cross section */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,9;
/* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
O0522 */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foil */
THK-TGT=43.6MG/CM**2;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5'Isochronous cyclotron, RCNP AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=65MEV;
BEAM-INTNSTY=50NA'6';
/* '6' maximum beam current */
POL-PRJ=82.5+-2.5%'7';
/* '7' The beam polarization was measured continuously with a
12C-polarimeter placed down stream the main scattering chamber
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=SCT'8';
/* '8' two liquid scintillation counters (NE213) to detect
neutrons */
/* Experimental Method:
- Time-of-flight (To determine outgoing neutron energy. The time
resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
corresponding energy resolutions of the neutrons were about 4 and
2 MeV for 50 and 30 MeV neutrons, respectively.)
RCT=93NB(P,N)X;
PHQ=ANGL-DSTRN;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,9;
INC-ENGY-LAB=65MEV;
SYS-ERR=10%'40';
/* '40' Estimated errors in the absolute magnitude of the cross
section due to uncertainties in the neutron detection
efficiency calculation */
EMT=N;
EXC-ENGY-MIN=28MEV;
EXC-ENGY-MAX=32MEV;
DELTA-THTL=+-0.6DEG'41';
/* '41' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA/DE=+-4.0%'42';
/* '42' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTL DSIGMA/DOMEGA/DE
(DEG) (MB/SR/MEV)
2.4 7.67
22.0 2.37
31.3 1.9
41.4 1.49
56.7 0.89
70.7 0.486
90.2 0.234
110.1 0.127
130.1 7.54E-02
\END;
/*===================================================================*/
|