/* NRDF D1769 Data No.88 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,88;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,88;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(40AR,N)X;
PHQ=ENGY-SPEC;
THK-TGT=720MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'274';
/* '274' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,88;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'275';
/* '275' Uncertainty in target thickness */
THTL=30DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'276'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 29.0 +-16.0
6 -1.05e+01 +-1.43e+01
7 10.5 +-12.3
8 0.00e+00 +-1.21e+01
9 0.00e+00 +-1.11e+01
10 0.00e+00 +-1.04e+01
20 2.77 +-2.09
40 3.56 +-1.81
60 8.83 +-1.80
80 11.7 +-2.0
100 13.3 +-1.9
120 10.8 +-1.9
140 11.9 +-1.8
160 9.36 +-1.59
180 8.43 +-1.68
200 8.57 +-1.48
230 9.58 +-1.17
260 6.41 +-0.91
290 6.85 +-0.82
320 5.27 +-0.70
360 4.61 +-0.59
400 3.76 +-0.41
460 2.64 +-0.29
520 1.32 +-0.20
600 0.791 +-0.145
720 0.351 +-0.105
880 9.88e-02 +-5.75e-02
1080 -7.91e-02 +-5.86e-02
1280 1.32e-02 +-1.04e-02
1480 -2.64e-02 +-3.90e-02
1680 1.32e-02 +-2.84e-02
1880 1.32e-02 +-2.02e-02
\END;
/*===================================================================*/
|