/* NRDF D1891 Data No.8 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,8;
D#=D1891;
TITLE=/ Gamow-Teller transitions in the (7Li, 7Be) reaction at 65A MeV
ATH=(S.NAKAYAMA'1', H.AKIMUNE'2', I.DAITO'2', H.FUJIMURA'2',
Y.FUJITA'3', M.FUJIWARA'2', K.FUSHIMI'1', T.INOMATA'2',
K.ISHIBASHI'2', H.KOHRI'2', N.KOORI'1', K.TAKAHISA'2', A.TAMII'4',
M.TANAKA'5', H.TOYOKAWA'6', T.YAMAGATA'7');
INST-ATH=(2JPNTKS'1', 2JPNRCN'2', 2JPNOSA'3', 2JPNKTO'4', 2JPNKTJ'5',
2JPNJSR'6', 2JPNKON'7');
/* '1' Department of Physics */
/* '3' Department of Physics */
/* '4' Department of Physics */
/* '7' Department of Physics */
REF=PR/C;
VLP=60(1999)047303;
RCTS=(6LI(7LI,7BE)6HE, 12C(7LI,7BE)12B, 28SI(7LI,7BE)28AL);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN-RATIO);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,8;
/* 2004-05-20 : Compiled, Sr + On */
CHM=ELM;
PHYS-FORM=SLD;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNRCN;
INC-ENGY-LAB=65MEV/A;
BEAM-INTNSTY=[1NA;
CHRG-INC-ION=3+;
POL-PRJ=0%;
DET-SYS=(MAG'8',SCT'9');
/* '8' Grand RAIDEN spectrograph [M. Fujiwara et al., Nucl.
Instrum. Meth. A422(1999)484] to analyze 7Be ejectiles. The
aperture of entrance slit of the Grand RAIDEN was set to be
+-25 mr horizontally and +-15 mr vertically. The angular
resolution in horizontal (theta) was about 2mr, but in vertical
(phi) was only about 10mr. */
/* '9' GSO gamma-detector system NYMPHS [S. Nakayama et al., Nucl.
Instrum. Meth. A404(1998)34] to detect 7Be 0.43 MeV gamma-ray.
The total absolute detection efficiency was about 0.2. */
ERS-DET=[500KEV'10';
/* '10' Mainly due to beam energy spreading */
RCT=12C(7LI,7BE)12B;
PHQ=XSECTN-RATIO;
ENR=98.9%;
THK-TGT=1.0MG/CM**2;
DET-PARTCL=(GAMMA'23',7BE);
/* '23' Prompt gamma from 7Be */
COINC=NO;
ANT-COINC=(GAMMA'24',7BE);
/* '24' Delayed gamma from 7Be */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,8;
INC-ENGY-LAB=65MEV/A;
RSD=12B;
EXC-ENGY-EMT=0.43MEV'25';
/* '25' Level energy for numerator of ratio */
EXC-ENGY-EMT=0.0MEV'26';
/* '26' Level energy for denominator of ratio */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC XSECTN-RATIO DELTA-XSECTN-RATIO
(DEG) (NODIM) (NODIM)
6.281E-01 8.113E-01 +-8.690E-02
1.399E+00 8.168E-01 +-9.392E-02
2.168E+00 7.824E-01 +-9.392E-02
2.739E+00 7.812E-01 +-1.127E-01
3.317E+00 7.988E-01 +-1.245E-01
3.878E+00 7.155E-01 +-1.198E-01
4.454E+00 8.764E-01 +-1.362E-01
\END;
/*===================================================================*/
|