/*===================================================================*/ /* NRDF D1411 Data No.76 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,76; /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,76; RCT=235U(P,FISSN)151PM; ENR=>99.0%; INC-ENGY-LAB-RANGE=9[18MEV; DET-PARTCL=GAMMA'220'; /* '220' Delayed gamma from 151Pm */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,76; TOT-ERR=X%'221'; /* '221' The errors cited originate from the consideration of gamma-counting statistics and the half-life fitting for the decay of the photopeak area. */ ENGY-GAMMA=340.1KEV'222'; INTNSTY-GAMMA=0.24'222'; HALF-LIFE=28.4HOUR'222'; /* '222' Delayed gamma from 151Pm */ /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; INC-ENGY-LAB SIGMA DELTA-SIGMA (MEV) (MB) (MB) 10.2 0.27 +-0.05 11.4 0.79 +-0.09 12.0 1.31 +-0.27 12.5 1.68 +-0.30 13.6 1.92 +-0.26 14.6 3.06 +-0.30 15.6 4.03 +-0.44 \END; /*===================================================================*/ |