|
| /*===================================================================*/
/* NRDF D1769 Data No.70 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,70;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,70;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=3600MG/CM**2;
INC-ENGY-LAB=600.0MEV/A;
ANL=X'220';
/* '220' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,70;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=600.0MEV/A;
SYS-ERR=6.8%'221';
/* '221' Uncertainty in target thickness */
THTL=80DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'222'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 2.71 +-1.26
6 5.41 +-0.86
7 2.46 +-0.84
8 2.46 +-0.83
9 3.20 +-0.65
10 2.21 +-0.70
15 1.13 +-0.20
25 1.35 +-0.18
35 1.28 +-0.16
45 1.11 +-0.16
55 1.03 +-0.17
65 0.886 +-0.166
75 0.787 +-0.157
85 0.467 +-0.152
95 0.738 +-0.159
105 0.418 +-0.134
125 0.406 +-0.091
145 0.320 +-0.063
165 0.234 +-0.054
185 0.172 +-0.056
205 0.172 +-0.050
235 7.38e-02 +-4.35e-02
265 7.38e-02 +-2.93e-02
295 2.46e-02 +-2.26e-02
325 3.28e-02 +-1.78e-02
365 3.69e-02 +-1.59e-02
405 6.15e-03 +-4.87e-03
465 2.46e-02 +-1.08e-02
525 1.23e-02 +-1.37e-02
605 3.08e-03 +-3.66e-03
725 6.15e-03 +-4.29e-03
885 6.15e-03 +-3.83e-03
1085 4.92e-03 +-2.84e-03
1285 0.00e+00 +-4.21e-04
1485 1.23e-03 +-1.68e-03
1685 2.46e-03 +-1.90e-03
1885 0.00e+00 +-4.03e-04
\END;
/*===================================================================*/
|