/* NRDF D1194 Data No.7 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,7;
D#=D1194;
TITLE=/ Optical model and folding model potentials for elastic
scattering of 56 MeV polarized deuterons /;
ATH=(N.MATSUOKA'1', H.SAKAI'1', T.SAITO'1', K.HOSONO'1', M.KONDO'1',
H.ITO'1', K.HATANAKA'2', T.ICHIHARA'2', A.OKIHANA'3', K.IMAI'4',
K.NISIMURA'5');
INST-ATH=(2JPNRCN'1', 2JPNIPC'2', 2JPNKUE'3', 2JPNKTO'4',
2JPNINS'5');
/* '3' Department of Physics */
/* '4' Department of Physics */
REF=NP/A;
VLP=455(1986)413;
RCTS=(12C(D,D)12C, 16O(D,D)16O, 40CA(D,D)40CA, 58NI(D,D)58NI,
90ZR(D,D)90ZR, 118SN(D,D)118SN, 144SM(D,D)144SM,
208PB(D,D)208PB);
PHQS=(ANGL-DSTRN, VCTR-ANALPW, TNSR-ANALPW, OPT-POTL-PARA);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,7;
/* 2007-01-31 : Converted, N.Otuka. Converted to EXFOR E1194 */
RTY=ELA-SCATT;
ENR=X%'6';
/* '6' Natural for 12C and 40Ca and enriched (96.7-99.8%) for
58Ni, 90Zr, 118Sn, 144Sm and 208Pb */
CHM=ELM;
THK-TGT=1.88[16.4MG/CM**2'7';
/* '7' 1140 Torr for 16O */
BAC=SELF;
ACC=CYC'8';
/* '8' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB-RANGE=56MEV;
BEAM-INTNSTY=10[200NA;
POL-PRJ=80[85%;
ION-SOURCE=/ Atomic beam source /;
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(CNTR-TLSCP'9',SI'9',NAI'9',EDE'10');
/* '9' To detect scattered particle */
/* '10' E and DE signal by Si and NaI detector */
ERS-DET=600KEV;
ANL=OPT-MODEL;
/* 2007-02-20 : Altered, At. Re-digitized */
RCT=144SM(D,D)144SM;
PHQ=ANGL-DSTRN;
PHYS-FORM=SLD;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,7;
INC-ENGY-LAB=56MEV;
SYS-ERR=8%'17';
/* '17' Uncertainty in absolute normalization, mainly due to
target thickness */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC RUTH-RATIO
(DEG) (NODIM)
1.301E+01 3.324E-01
1.621E+01 3.863E-01
1.891E+01 3.032E-01
2.030E+01 1.473E-01
2.224E+01 1.263E-01
2.479E+01 2.534E-01
2.643E+01 3.148E-01
2.872E+01 2.265E-01
3.075E+01 6.104E-02
3.287E+01 2.437E-02
3.483E+01 1.027E-01
3.615E+01 1.695E-01
3.850E+01 1.585E-01
4.147E+01 7.694E-02
4.276E+01 2.581E-02
4.514E+01 2.633E-02
4.763E+01 4.155E-02
4.963E+01 4.528E-02
5.078E+01 3.882E-02
5.312E+01 3.629E-02
5.514E+01 4.042E-02
5.751E+01 4.307E-02
5.906E+01 3.692E-02
6.099E+01 3.096E-02
6.253E+01 2.713E-02
6.377E+01 3.370E-02
6.546E+01 4.878E-02
6.825E+01 5.429E-02
7.061E+01 5.187E-02
7.294E+01 4.444E-02
7.448E+01 3.809E-02
7.764E+01 3.884E-02
7.965E+01 4.324E-02
8.205E+01 4.814E-02
\END;
/*===================================================================*/
|