/* NRDF D1769 Data No.68 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,68;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,68;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=3600MG/CM**2;
INC-ENGY-LAB=600.0MEV/A;
ANL=X'214';
/* '214' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,68;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=600.0MEV/A;
SYS-ERR=6.8%'215';
/* '215' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'216'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 8.66 +-3.60
6 7.79 +-2.94
7 2.16 +-3.00
8 -3.46e+00 +-3.25e+00
9 4.33 +-2.54
10 -8.66e-01 +-2.54e+00
15 1.64 +-0.63
25 1.77 +-0.57
35 0.00e+00 +-7.17e-01
45 1.64 +-0.63
55 0.996 +-0.597
65 1.73 +-0.54
75 2.90 +-0.59
85 2.25 +-0.57
95 1.82 +-0.58
105 0.866 +-0.611
125 2.90 +-0.44
145 1.88 +-0.36
165 1.51 +-0.38
185 1.80 +-0.32
205 1.21 +-0.30
235 1.96 +-0.30
265 1.30 +-0.21
295 1.34 +-0.16
325 1.05 +-0.19
365 1.08 +-0.14
405 0.671 +-0.120
465 0.541 +-0.097
525 0.296 +-0.068
605 0.195 +-0.046
725 7.21e-02 +-2.80e-02
885 5.41e-02 +-1.38e-02
1085 3.25e-02 +-9.36e-03
1285 1.51e-02 +-6.41e-03
1485 1.08e-02 +-5.56e-03
1685 8.66e-03 +-4.75e-03
1885 4.33e-03 +-3.06e-03
\END;
/*===================================================================*/
|