|
| /*===================================================================*/
/* NRDF D1586 Data No.68 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,68;
D#=D1586;
TITLE=/ Single-particle states in 59Ni with 58Ni(d,p)59Ni reaction
at 56 MeV and neutron-bound-state complex potentials /;
PURPOSE=/ To measure the cross sections and analyzing powers /;
ATH=(O.IWAMOTO'1', A.NOHTOMI'1', Y.UOZUMI'1', T.SAKAE'1', M.MATOBA'1',
M.NAKANO'2', T.MAKI'2', N.KOORI'3');
INST-ATH=(2JPNKYU'1', 2JPNKIT'2', 2JPNTKS'3');
/* '1' Department of Nuclear Engineering */
/* '2' School of Nursing and Technology */
/* '3' Faculty of Integrated Arts and Sciences */
REF=NP/A;
VLP=576(1994)387;
RCTS=58NI(D,P)59NI;
PHQS=(SPEC-FCTR, ANGL-DSTRN, VCTR-ANALPW, SPEC-FCTR'4');
/* '4' Sum of spectroscopic factor */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,68;
/* 2005-09-24 : Converted, Sr + On. Converted to EXFOR E1586 */
/* 2005-11-07 : Altered, At + Kc + Sr. Re-digitized */
/* Related references
- N.Matsuoka et al., NP/A, 455(1986)413.
ENR=99.89%;
CHM=ELM;
PHYS-FORM=SLD;
THK-TGT=0.473MG/CM**2;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5' Isochronous cyclotron, AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=56MEV;
POL-PRJ=[50%;
DET-PARTCL=P;
COINC=NO;
ANT-COINC=NO;
DET-SYS=MAG'6';
/* '6' Magnetic spectrograph RAIDEN [H.Ikegami, et al. Nucl.
Instr. Meth. 175(1980)33] with the focal-plane detector system
KYUSHYU [M.Matoba, et al. Nucl. Instr. Meth. 180(1981)419] */
ERS-DET=45KEV;
ANL=DWBA'7';
/* '7' Code DWUCK [P.D.Kunz, code DWUCK, University of Colorado
(unpublished)] */
RCT=58NI(D,P)59NI;
PHQ=SPEC-FCTR'305';
/* '305' Sum of spectroscopic factor */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,68;
INC-ENGY-LAB=56MEV;
SYS-ERR=X%'306';
/* '306' Uncertainty in run-to-run variations of the integrated
beam current are on the order of a few percent. */
EMT=P;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
TRNSF-L TRNSF-J'307' SPEC-FCTR'308' SPEC-FCTR'309'
(NODIM) (NODIM) (NODIM) (NODIM)
1 3/2 0.664 0.850
3 5/2 0.834 0.849
1 1/2 0.877 0.986
3 7/2 0.026 0.026
4 9/2 0.418 0.504
2 5/2 0.290 0.438
0 1/2 0.360 0.573
\END;
/*===================================================================*/
|