/* NRDF D1769 Data No.62 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,62;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,62;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=2270MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'196';
/* '196' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,62;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'197';
/* '197' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'198'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 480 +-39
6 371 +-41
7 308 +-34
8 254 +-29
9 208 +-28
10 181 +-24
15 82.4 +-6.7
25 57.1 +-6.1
35 50.7 +-5.7
45 47.1 +-5.1
55 43.5 +-5.4
65 41.7 +-6.1
75 33.5 +-4.9
85 35.3 +-6.1
95 22.6 +-6.1
105 36.2 +-4.8
125 25.4 +-3.3
145 20.8 +-2.9
165 14.0 +-2.6
185 9.51 +-1.50
205 8.60 +-2.37
235 6.94 +-1.66
265 2.42 +-1.12
295 3.92 +-1.24
325 3.02 +-0.73
365 1.36 +-0.83
405 0.00e+00 +-7.02e-01
465 0.453 +-0.233
525 0.302 +-0.145
605 0.113 +-0.099
725 0.151 +-0.074
885 0.170 +-0.084
1085 0.136 +-0.064
1285 4.53e-02 +-4.06e-02
1485 4.53e-02 +-2.88e-02
1685 4.53e-02 +-4.35e-02
1885 0.00e+00 +-2.17e-02
\END;
/*===================================================================*/
|