|
| /*===================================================================*/
/* NRDF D1769 Data No.60 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,60;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,60;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=2270MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'190';
/* '190' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,60;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'191';
/* '191' Uncertainty in target thickness */
THTL=30DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'192'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 386 +-161
6 416 +-117
7 446 +-96
8 223 +-97
9 238 +-87
10 178 +-73
15 81.7 +-20.3
25 74.3 +-15.0
35 71.3 +-13.7
45 41.6 +-14.8
55 47.5 +-13.0
65 69.8 +-14.0
75 47.5 +-17.8
85 78.7 +-15.0
95 59.4 +-14.5
105 60.9 +-15.2
125 76.5 +-11.5
145 44.6 +-11.3
165 37.9 +-9.7
185 28.2 +-10.5
205 20.8 +-8.8
235 38.6 +-7.9
265 12.9 +-6.5
295 18.8 +-3.9
325 17.8 +-3.2
365 15.6 +-3.0
405 7.05 +-1.83
465 6.19 +-1.32
525 1.49 +-1.06
605 1.49 +-0.40
725 0.124 +-0.504
885 0.186 +-0.151
1085 7.43e-02 +-5.92e-02
1285 7.43e-02 +-6.87e-02
1485 0.00e+00 +-9.33e-03
1685 7.43e-02 +-7.23e-02
1885 7.43e-02 +-5.55e-02
\END;
/*===================================================================*/
|