/* NRDF D1849 Data No.6 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,6;
D#=D1849;
TITLE=/Some evidence for neutron pick-up from the interior core
through the (p,d) reaction/;
ATH=(T.ISHIMATSU'1', S.HAYASHIBE'1', N.KAWAMURA'1', T.AWAYA'2',
H.OHMURA'2', Y.NAKAJIMA'3', S.MITARAI'3');
INST-ATH=(2JPNTOH'1', 2JPNTOK'2', 2JPNKYU'3');
/* '1' Department of Physics */
/* '2' Department of Physics */
/* '3' Department of Physics */
REF=NP/A;
VLP=185(1972)273;
RCTS=(100MO(P,D)99MO, 94MO(P,D)93MO, 98MO(P,D)97MO);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,6;
/* 2003-10-31 : Converted, Data converted from EXFOR O0586 */
PHQ=ANGL-DSTRN;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foils */
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=52MEV;
POL-PRJ=0%;
DET-PARTCL=D;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',PLST-SCT);
/* '5' Broad-range magnetic spectrometer [K.Yagi et al., Nucl.
Instr. 52(1967)29] */
/* '6' 200 proportional counters along the focal plane followed by
a plastic scintillation counter with 6 phototubes */
/* Experimental Method:
- Pulse-height discrimination (Aluminium foils placed in tront of
proportional counters and a pulse-height discriminator for the
outputs from the scintillation counters allowed the elimination
of triton backgrounds from deuteron spectra.)
RCT=98MO(P,D)97MO;
ENR=97.0%;
THK-TGT=3.12MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,6;
INC-ENGY-LAB=52MEV;
SYS-ERR=(10%'29',X%'30');
/* '29' Uncertainty in the solid angle of spectrometer */
/* '30' Uncertainties in the absolute cross sections are
estimated to be less than +-20%. */
EMT=D;
RSD=97MO;
EXC-ENGY=1.28MEV;
DELTA-EXC-ENGY=0.02MEV;
J-PTY=3/2+;
DELTA-THTL=0.23DEG'31';
/* '31' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.6%'32';
/* '32' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTL DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA'33'
(DEG) (MB/SR) (%)
4.83 2.12 +-X
7.09 1.92 +-X
9.97 1.451 +-X
12.19 1.056 +-X
15.02 0.641 +-X
17.22 0.423 +-X
19.52 0.454 +-X
21.98 0.475 +-X
24.75 0.451 +-X
27.9 0.267 +-X
31.2 0.1452 +-2.
34.05 0.097 +-2.
37.19 0.1118 +-3.
39.95 0.1062 +-3.
42.98 0.0763 +-4.
45.64 0.043 +-4.
48.84 0.0325 +-4.
52.57 0.0283 +-4.
56.48 0.0271 +-5.
\END;
/*===================================================================*/
|