/* NRDF D1370 Data No.6 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,6;
D#=D1370;
TITLE=/ Pre-equilibrium process in 3He-induced reactions on 59Co,
109Ag, 181Ta and 209Bi /;
ATH=(Y.NAGAME'1', Y.NAKAMURA'2', M.TAKAHASHI'2', K.SUEKI'2',
H.NAKAHARA'2');
INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
/* '1' Department of Radioisotopes */
/* '2' Department of Chemistry, Faculty of Science */
REF=NP/A;
VLP=486(1988)77;
RCTS=(59CO(3HE,N)61CU, 59CO(3HE,2*N)60CU, 59CO(3HE,2*N,2*P)58CO,
59CO(3HE,N,ALPHA)57CO, 59CO(3HE,2*N,ALPHA)56CO,
59CO(3HE,2*P)60CO, 109AG(3HE,N)111IN, 109AG(3HE,2*N)110IN,
109AG(3HE,3*N)109IN, 109AG(3HE,2*N,P)109CD, 209BI(3HE,N)211AT,
209BI(3HE,2*N)210AT, 209BI(3HE,3*N)209AT, 209BI(3HE,4*N)208AT,
209BI(3HE,2*N,ALPHA)206BI, 181TA(3HE,N)183RE);
PHQS=EXC-FUNCT;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,6;
/* 2006-05-23 : Converted, N.Otuka. Converted to EXFOR E1370 */
PHQ=EXC-FUNCT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC;
BEAM-INTNSTY=[0.5UA;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
ANL=PREEQUI-MODEL'3';
/* '3' Code ALICE /LIVERMORE /85 /300 */
/* Experimental Method:
- Stacked target irradiation (Constructed by targets and Al
catcher foils)
/* 2006-06-09 : Altered, Is. Re-digitized */
/* Related references
- R.Michel et al., NP/A, 404(1983)77.
Reference with which data agree. See also EXFOR A0210.004.
RCT=59CO(3HE,2*P)60CO;
THK-TGT=5[10MG/CM**2;
DET-PARTCL=GAMMA'25';
/* '25' Delayed gamma from 60Co */
DET-SYS=GE(LI)'26';
/* '26' To measure radioactivities */
/* Experimental Method:
- Chemical separation
- Gamma ray spectrometry
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,6;
SYS-ERR=(2%'4',5%'5',3%'6',20%'7',8%'8');
/* '4' Uncertainty in current integration with a Faraday cup */
/* '5' Maximum uncertainty in target thickness (2-5%) */
/* '6' Uncertainty in detector efficiency */
/* '7' Maximum uncertainty in gamma- or alpha-ray peak analysis */
/* '8' Uncertainty in chemical yield */
ENGY-GAMMA=1332KEV'27';
INTNSTY-GAMMA=1.00'27';
HALF-LIFE=5.26YEAR'27';
/* '27' Delayed gamma from 60Co */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA
(MEV) (MB)
1.036E+01 3.739E+00
1.274E+01 2.604E+01
1.335E+01 4.001E+01
1.518E+01 5.410E+01
1.710E+01 6.543E+01
1.761E+01 5.491E+01
1.834E+01 8.239E+01
1.914E+01 9.459E+01
2.075E+01 7.660E+01
2.171E+01 8.559E+01
2.310E+01 8.286E+01
2.406E+01 9.408E+01
2.536E+01 8.279E+01
2.658E+01 8.818E+01
2.701E+01 7.169E+01
2.866E+01 7.395E+01
2.953E+01 7.511E+01
3.075E+01 8.001E+01
3.179E+01 7.269E+01
3.405E+01 6.194E+01
3.457E+01 7.033E+01
3.614E+01 7.983E+01
3.649E+01 6.807E+01
3.823E+01 6.589E+01
\END;
/*===================================================================*/
|