/* NRDF D1434 Data No.52 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,52;
D#=D1434;
TITLE=/Nuclear structure of even lead isotopes by the (p,t) reaction/;
ATH=(M.TAKAHASHI'1', T.MURAKAMI'1', S.MORITA'1', H.ORIHARA'2',
Y.ISHIZAKI'3', H.YAMAGUCHI'4');
INST-ATH=(2JPNTOH'1', 2JPNTOH'2', 2JPNINS'3', 2JPNTKS'4');
/* '1' Department of Physics */
/* '2' Cyclotron and Radioisotope Center */
/* '3' Institute for Nuclear Study */
/* '4' Faculty of General Education */
REF=PR/C;
VLP=27(1983)1454;
RCTS=(208PB(P,T)206PB, 206PB(P,T)204PB, 204PB(P,T)202PB);
PHQS=ANGL-DSTRN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,52;
/* 2003-10-24 : Converted, Data converted to EXFOR E1434 and EXFOR
O0685 */
PHQ=ANGL-DSTRN;
ENR=>99%;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYNCYC;
INST-ACC=2JPNINS;
INC-ENGY-LAB=51.9MEV;
POL-PRJ=0%;
DET-PARTCL=T;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(MAG'5',PROP-CNTR'6',SCT);
/* '5' To analyze triton momentum */
/* '6' Array of 200 proportional counters serve as position
detectors. They form counter telescopes in combination with
scintillation counters. */
ERS-DET=[90KEV'7';
/* '7' Overall energy resolution for the tritons of interest */
ANL=DWBA'8';
/* '8' Zero-range DWBA approximation (code DWUCK-4, [W.A.Lanford
and J.B.McGrory, Michigan State University Cyclotron Laboratory
Report No.MSUCL-81, 1973 (unpublished); Phys. Lett.
45B(1973)283]) */
RCT=204PB(P,T)202PB;
CHM=ELM'239';
/* '239' Prepared by centrifugal settling of PbO */
PHYS-FORM=SLD;
THK-TGT=2MG/CM**2;
BAC=MYLAR;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,52;
INC-ENGY-LAB=51.9MEV;
SYS-ERR=<20%'240';
/* '240' Error of the absolute cross section of the ground state
transition is estimated to be less than 20%, where the main
part comes from the uncertainty of the solid angle of each
counter on the focal plane of the magnetic spectrograph. */
EMT=T;
RSD=202PB;
EXC-ENGY=3.2MEV;
J-PTY=8+;
DELTA-THTC=0.25DEG'241';
/* '241' Data-point reader uncertainty */
DELTA-DSIGMA/DOMEGA=1.9%'242';
/* '242' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA
(DEG) (UB/SR)
6.54 49.2
7.78 57.6
10.16 44.5
12.67 49.6
14.83 49.1
17.73 43.2
20.25 45.6
22.79 37.7
25.33 34.9
27.7 28.8
30.42 24.7
32.68 11.79
34.88 9.47
37.79 7.72
40.47 8.93
45.25 4.5
50.64 5.1
55.75 3.12
60.79 3.23
\END;
/*===================================================================*/
|