|
| /*===================================================================*/
/* NRDF D1872 Data No.5 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,5;
D#=D1872;
TITLE=/ (d,alpha) reactions on 19F, 20Ne, 31P and 32S at 14.7 MeV /;
ATH=(K.TAKAMATSU'1');
INST-ATH=(2JPNKTO'1');
/* '1' Department of Physics, Faculty of Science */
REF=JPJ;
VLP=17(1962)896;
RCTS=(19F(D,ALPHA)17O, 31P(D,ALPHA)29SI, 20NE(D,ALPHA)18F,
32S(D,ALPHA)30P, 24MG(D,ALPHA)22NA);
PHQS=(ANGL-DSTRN, XSECTN);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,5;
/* 2004-02-20 : Compiled, Ic + On */
/* Related references
- K.Kimura et al., JPJ, 17(1962)9.
(Details of beam handling and scattering chamber)
- T.Yanabu et al., JPJ, 17(1962)914.
(Details of detecting system)
- M.el Nadi, PR, 119(1960)242.
(Two-nucleon picjup process formula used in analysis)
- H.C.Newns, PPS, 76(1960)489.
(Two-nucleon picjup process formula used in analysis)
/* Additional results shown but not compiled
- Energy distribution (Typical pulse-height spectrum (channel
number v.s. counts/channel) of alpha particlles are shown for
19F, 20Ne, 31P and 32S target.)
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNKTO;
POL-PRJ=0%;
DET-PARTCL=ALPHA;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SI'2',CSI'3');
/* '2' To detect alpha. Energy calibration was done with the alpha
particles produced in the known reactions such as
27Al(p,alpha)24Mg, 16O(d,alpha)14N and 27Al(d,alpha)25Mg etc.
/* '3' CSI(Tl) scintillation counter to monitor the beam current
of incident deuterons */
ERS-DET=1.2%'4';
/* '4' Value at 20 MeV */
/* Experimental Method:
- Beam current integrated (Conventional current integrator with
an accuracy better than 10%)
/* 2006-10-05 : Altered, Is. Re-digitized */
RCT=19F(D,ALPHA)17O;
PHQ=ANGL-DSTRN;
CHM=X'18';
/* '18' Polytetra-fluorethylene (Teflon) */
PHYS-FORM=SLD;
THK-TGT=0.76MG/CM**2;
INC-ENGY-LAB=14.7MEV;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,5;
INC-ENGY-LAB=14.7MEV;
SYS-ERR=<30%'19';
/* '19' Maximum uncertainty of absolute values arise from beam
current and target thickness estimation */
EXC-ENGY=4.555MEV;
J-PTY=3/2-;
DELTA-THTL=+-1.5DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
THTC DSIGMA/DOMEGA
(DEG) (MB/SR)
2.330E+01 5.388E-02
3.393E+01 3.609E-02
4.555E+01 4.601E-02
5.619E+01 2.821E-02
6.685E+01 2.302E-02
7.660E+01 2.919E-02
8.680E+01 2.526E-02
9.653E+01 1.756E-02
1.077E+02 2.245E-02
1.267E+02 2.344E-02
\END;
/*===================================================================*/
|