/* NRDF D1370 Data No.5 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,5;
D#=D1370;
TITLE=/ Pre-equilibrium process in 3He-induced reactions on 59Co,
109Ag, 181Ta and 209Bi /;
ATH=(Y.NAGAME'1', Y.NAKAMURA'2', M.TAKAHASHI'2', K.SUEKI'2',
H.NAKAHARA'2');
INST-ATH=(2JPNJAE'1', 2JPNTMU'2');
/* '1' Department of Radioisotopes */
/* '2' Department of Chemistry, Faculty of Science */
REF=NP/A;
VLP=486(1988)77;
RCTS=(59CO(3HE,N)61CU, 59CO(3HE,2*N)60CU, 59CO(3HE,2*N,2*P)58CO,
59CO(3HE,N,ALPHA)57CO, 59CO(3HE,2*N,ALPHA)56CO,
59CO(3HE,2*P)60CO, 109AG(3HE,N)111IN, 109AG(3HE,2*N)110IN,
109AG(3HE,3*N)109IN, 109AG(3HE,2*N,P)109CD, 209BI(3HE,N)211AT,
209BI(3HE,2*N)210AT, 209BI(3HE,3*N)209AT, 209BI(3HE,4*N)208AT,
209BI(3HE,2*N,ALPHA)206BI, 181TA(3HE,N)183RE);
PHQS=EXC-FUNCT;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,5;
/* 2006-05-23 : Converted, N.Otuka. Converted to EXFOR E1370 */
PHQ=EXC-FUNCT;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC;
INST-ACC=2JPNIPC;
BEAM-INTNSTY=[0.5UA;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
ANL=PREEQUI-MODEL'3';
/* '3' Code ALICE /LIVERMORE /85 /300 */
/* Experimental Method:
- Stacked target irradiation (Constructed by targets and Al
catcher foils)
/* 2006-06-09 : Altered, Is. Re-digitized */
/* Related references
- R.Michel et al., NP/A, 404(1983)77.
Reference with which data agree. See also EXFOR A0210.007.
RCT=59CO(3HE,2*N,ALPHA)56CO;
THK-TGT=5[10MG/CM**2;
DET-PARTCL=GAMMA'22';
/* '22' Delayed gamma from 56Co */
DET-SYS=GE(LI)'23';
/* '23' To measure radioactivities */
/* Experimental Method:
- Chemical separation
- Gamma ray spectrometry
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,5;
SYS-ERR=(2%'4',5%'5',3%'6',20%'7',8%'8');
/* '4' Uncertainty in current integration with a Faraday cup */
/* '5' Maximum uncertainty in target thickness (2-5%) */
/* '6' Uncertainty in detector efficiency */
/* '7' Maximum uncertainty in gamma- or alpha-ray peak analysis */
/* '8' Uncertainty in chemical yield */
ENGY-GAMMA=847KEV'24';
INTNSTY-GAMMA=1.00'24';
HALF-LIFE=77.3DAY'24';
/* '24' Delayed gamma from 56Co */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
INC-ENGY-LAB SIGMA
(MEV) (MB)
1.778E+01 1.896E-01
1.945E+01 3.425E+00
2.085E+01 3.318E+00
2.137E+01 3.893E+00
2.251E+01 7.743E+00
2.417E+01 1.491E+01
2.566E+01 2.297E+01
2.609E+01 2.695E+01
2.706E+01 2.919E+01
2.854E+01 3.112E+01
2.933E+01 3.831E+01
3.064E+01 4.495E+01
3.160E+01 5.275E+01
3.274E+01 4.870E+01
3.370E+01 5.275E+01
3.475E+01 4.792E+01
3.624E+01 4.568E+01
3.685E+01 5.275E+01
3.816E+01 3.956E+01
3.895E+01 4.792E+01
\END;
/*===================================================================*/
|