/* NRDF D1242 Data No.5 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,5;
D#=D1242;
TITLE=/ Nuclear reactions of 48Ti, 56Fe, 57Fe, 58Ni, 60Ni, 63Cu, and
65Cu by 12-GeV protons /;
ATH=(M.NOGUCHI'1', H.HIRABAYASHI'1', K.KATOH'1', K.KONDO'1',
M.TAKASAKI'1', Y.ASANO'2', S.MORI'2', M.SAKANO'2');
INST-ATH=(2JPNKEK'1', 2JPNTSU'2');
/* '2' Institute of Applied Physics */
REF=PR/C;
VLP=38(1988)1811;
RCTS=(48TI(P,X)X, 56FE(P,X)X, 57FE(P,X)X, 58NI(P,X)X, 60NI(P,X)X,
63CU(P,X)X, 65CU(P,X)X);
PHQS=XSECTN;
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,5;
/* 2007-01-18 : Converted, N.Otuka. Converted to EXFOR E1242 */
PHQ=XSECTN;
/* Additional results shown but not compiled
- Charge distribution (Shown in Fig.6 in reference)
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN;
INST-ACC=2JPNKEK;
INC-ENGY-LAB-RANGE=12GEV;
POL-PRJ=0%;
DET-PARTCL=GAMMA'3';
/* '3' Decay data not given */
COINC=NO;
ANT-COINC=NO;
DET-SYS=GE(LI)'4';
/* '4' For gamma-ray spectroscopy */
/* Experimental Method:
- Stacked target irradiation
- Activation (Irradiated for 14 min)
- Gamma ray spectrometry (Performed during 3 months starting
about 4 hours after the end of irradiation. In addition 56Fe and
57Fe targets were measured about 15 months after irradiation.)
/* By authors: Measurements of short-lived nuclides with lifetimes
much shorter than a few hours were precluded. */
RCT=57FE(P,X)X'16';
/* '16' See DATA section for atomic number (Z) and mass number
(A) of products */
ENR=90.68%;
CHM=FE2.O3;
THK-TGT=10MG/CM**2;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,5;
INC-ENGY-LAB=12GEV;
TOT-ERR=X%'5';
/* '5' Uncertainty in detection efficiency of gamma rays and
statistical errors for photopeak yields (Uncertainties in
normalization are not included.) */
SYS-ERR=(10%'6',15%'7');
/* '6' Uncertainty in beam intensity calibration */
/* '7' Maximum uncertainty in detection efficiency (15% below 200
keV, 10% at 200-400 keV, 5% above 400 keV) */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
Z A ISOMER SIGMA',17' DELTA-SIGMA''
(NODIM) (NODIM) (NODIM) (MB) (MB)
19. 42 X 3.7 +-0.3
21. 44 0 2.9 +-0.18
21. 44 1 3.7 +-0.2
21. 46 X 6.1 +-0.3
21. 48 X 0.56 +-0.06
24. 48 X 0.12 +-0.01
25. 52 X 2.6 +-0.14
25. 54 X 23 +-1.2
27. 58 X 0.20 +-0.02
\END;
/*===================================================================*/
|