/* NRDF D0815 Data No.5 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,5;
D#=D815;
TITLE=/Analyzing power of the neutron continuum spectrum for the
93Nb(p,nX) reaction at 65 MeV and a DWBA analysis/;
PURPOSE=/To provide stringent test for various theories by simultaneous
fitting of analyzing powers as well as cross sections for both
neutron and proton spectra/;
ATH=(H.SAKAI'1', K.HATANAKA'1', N.MATSUOKA'1', T.SAITO'1',
A.SHIMIZU'1', T.MOTOBAYASHI'2', T.SHIBATA'1');
INST-ATH=(2JPNRCN'1', 2JPNOSA'2');
/* '2' Department of Physics */
REF=PL/B;
VLP=133(1983)375;
RCTS=93NB(P,N)X;
PHQS=(ENGY-SPEC'3', ANALPW, ANGL-DSTRN);
/* '3' Double differential cross section */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,5;
/* 2003-10-24 : Converted, Data converted to EXFOR E815 and EXFOR
O0522 */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD'4';
/* '4' Metallic foil */
THK-TGT=43.6MG/CM**2;
BAC=SELF;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=CYC'5';
/* '5'Isochronous cyclotron, RCNP AVF cyclotron */
INST-ACC=2JPNRCN;
INC-ENGY-LAB=65MEV;
BEAM-INTNSTY=50NA'6';
/* '6' maximum beam current */
POL-PRJ=82.5+-2.5%'7';
/* '7' The beam polarization was measured continuously with a
12C-polarimeter placed down stream the main scattering chamber
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=SCT'8';
/* '8' two liquid scintillation counters (NE213) to detect
neutrons */
/* Experimental Method:
- Time-of-flight (To determine outgoing neutron energy. The time
resolution (FWHM) of the beam burst was typically 1.0-1.5 ns, and
corresponding energy resolutions of the neutrons were about 4 and
2 MeV for 50 and 30 MeV neutrons, respectively.)
RCT=93NB(P,N)X;
PHQ=ANALPW;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,5;
INC-ENGY-LAB=65MEV;
SYS-ERR=10%'25';
/* '25' Estimated errors in the absolute magnitude of the cross
section due to uncertainties in the neutron detection
efficiency calculation */
EMT=N;
THTL=30DEG;
DELTA-ENGY-EMT-LAB=+-0.28MEV'26';
/* '26' Data-point reader uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB ANALPW DELTA-ANALPW'27'
(MEV) (NODIM) (NODIM)
14.87 -0.006 +-0.008
18.59 0.01 +-0.006
20.33 0.005 +-0.0027
22.09 0.011 +-0.007
23.22 0.012 +-0.004
24.86 0.037 +-0.009
26.04 0.013 +-0.005
27.19 0.023 +-0.005
28.17 0.025 +-0.005
29.71 0.037 +-0.006
31.47 0.042 +-0.005
32.41 0.061 +-0.006
33.59 0.059 +-0.005
35.3 0.087 +-0.007
37.53 0.059 +-0.009
38.46 0.08 +-0.005
39.71 0.055 +-0.009
40.71 0.046 +-0.01
41.5 0.045 +-0.008
42.4 0.081 +-0.005
44. 0.068 +-0.006
44.6 0.067 +-0.007
45.72 0.011 +-0.012
46.46 0.029 +-0.01
47.4 0.046 +-0.008
48.69 0.003 +-0.013
49.86 0.007 +-0.015
50.69 -0.01 +-0.013
51.82 0.013 +-0.011
52.8 0.011 +-0.016
54.09 0.048 +-0.011
55.09 0.116 +-0.014
55.89 0.119 +-0.017
\END;
/*===================================================================*/
|