/* NRDF D1809 Data No.48 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,48;
D#=D1809;
TITLE=/Spectral measurements of neutrons, protons, deuterons and
tritons produced by 100 MeV/nucleon He bombardment/;
PURPOSE=/To present the angular-energy distributions of neutrons,
protons, deuterons and tritons produced from thick carbon,
aluminum, copper and lead targets bombarded by 100 MeV/nucleon
helium ion. /;
ATH=(T.KUROSAWA'1', T.NAKAMURA'1', N.NAKAO'2', T.SHIBATA'3',
Y.UWAMINO'4', A.FUKUMURA'5');
INST-ATH=(2JPNTOH'1', 2JPNKEK'2', 2JPNKEK'3', 2JPNIPC'4', 2JPNIRS'5');
/* '1' Cyclotron and Radioisotope Center */
/* '2' Tanashi Branch */
REF=NIM/A;
VLP=430(1999)400;
RCTS=(12C(ALPHA,P)X, 27AL(ALPHA,P)X, CU(ALPHA,P)X, PB(ALPHA,P)X,
12C(ALPHA,D)X, 27AL(ALPHA,D)X, CU(ALPHA,D)X, PB(ALPHA,D)X,
12C(ALPHA,T)X, 27AL(ALPHA,T)X, CU(ALPHA,T)X, PB(ALPHA,T)X);
PHQS=ENGY-SPEC'6';
/* '6' Double differential thick target yield */
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,48;
/* 2003-09-13 : Compiled */
PHQ=ENGY-SPEC'7';
/* '7' Double differential thick target yield */
ENR=X%;
CHM=ELM;
PHYS-FORM=SLD;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'8';
/* '8' Heavy Ion Medical Accelerator in Chiba (HIMAC) */
INST-ACC=2JPNIRS;
INC-ENGY-LAB=100MEV/A;
POL-PRJ=0%;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF'11',EDE'12');
/* '9' Plastic scintillator (NE102A) was used as the delta-E
counter, ToF start signal detector, and incident projectile
counter */
/* '10' Liquid scintillator (NE213) was used as the E counter */
/* '11' To measure the energy of outgoing neutrons, protons,
deuterons and tritons */
/* '12' To eliminate charged particles */
ANL=MONTE-MTHD'13';
/* '13' LAHET Monte Carlo Code System, LCS [R.E. Prael, H.
Lichtenstein, LA-UR-89-3014, Los Alamos National Laboratory,
1989.] */
/* Experimental Method:
- Time-of-flight (To measure the energy of outgoing neutrons,
protons, deuterons and tritons)
- Particle identification by 'E/Delta E' measurement (To
eliminate charged particles)
RCT=12C(ALPHA,T)X;
THK-TGT=8850MG/CM**2;
DET-PARTCL=T;
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,48;
INC-ENGY-LAB=100MEV/A;
SYS-ERR=(<3%'302',<1%'303',<1%'304');
/* '302' Uncertainty in the number of accepted beam particles
incident on the target is estimated to be less than 3%. */
/* '303' Uncertainty in the solid angle for the thickest carbon
target, which has the maximum uncertainty, is less than 1%.
/* '304' Uncertainty of charged particle detection efficiency is
estimated to be 1%, considering a small fraction of the slant
incidence of a particle onto the detector. */
STATIST-ERR=X%'305';
/* '305' The statistical uncertainties vary from 2-5% in the low
to medium energy (5-50 MeV) region of the spectra and
increase to about 30% at the highest energies. */
EMT=T;
THTL=30DEG;
DELTA-DN/DOMEGA/DE=<4%'306';
/* '306' Total normalization uncertainty */
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB-MIN ENGY-EMT-LAB-MAX DN/DOMEGA/DE'307'
(MEV) (MEV) (1/SR/MEV/PARTCL)
49.162 54.729 2.3940e-05
54.729 60.834 2.6563e-05
60.834 67.478 2.6178e-05
67.478 74.641 2.1753e-05
74.641 83.027 1.9048e-05
83.027 92.042 1.6304e-05
92.042 102.64 1.0034e-05
102.64 113.98 8.6403e-06
113.98 127.36 4.5419e-06
127.36 141.57 3.6535e-06
141.57 158.38 1.8948e-06
158.38 176.05 1.3031e-06
176.05 196.97 3.9823e-07
196.97 218.61 2.4900e-07
\END;
/*===================================================================*/
|