/* NRDF D1769 Data No.48 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,48;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,48;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1800MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'154';
/* '154' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,48;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'155';
/* '155' Uncertainty in target thickness */
THTL=60DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'156'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 3.99 +-3.06
6 3.99 +-2.46
7 5.33 +-1.95
8 1.33 +-2.05
9 2.66 +-1.47
10 2.66 +-1.86
20 2.16 +-0.35
40 1.60 +-0.36
60 2.36 +-0.31
80 2.36 +-0.31
100 1.96 +-0.32
120 1.53 +-0.28
140 1.83 +-0.22
160 1.17 +-0.22
180 0.699 +-0.162
200 0.799 +-0.130
230 0.865 +-0.137
260 0.399 +-0.095
290 0.178 +-0.110
320 0.155 +-0.089
360 4.99e-02 +-6.35e-02
400 1.66e-02 +-6.19e-02
460 4.44e-02 +-1.79e-02
520 2.22e-02 +-1.46e-02
600 2.50e-02 +-1.16e-02
720 1.11e-02 +-6.62e-03
880 8.32e-03 +-5.79e-03
1080 9.99e-03 +-5.36e-03
\END;
/*===================================================================*/
|