/* NRDF D1769 Data No.47 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,47;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,47;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1800MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'151';
/* '151' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,47;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'152';
/* '152' Uncertainty in target thickness */
THTL=40DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'153'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 1.73 +-5.37
6 3.46 +-4.30
7 5.19 +-3.90
8 4.33 +-3.76
9 4.33 +-3.43
10 1.73 +-3.40
20 1.99 +-0.68
40 2.81 +-0.62
60 3.07 +-0.55
80 1.34 +-0.73
100 2.60 +-0.66
120 2.38 +-0.58
140 2.86 +-0.52
160 2.64 +-0.50
180 1.73 +-0.45
200 2.25 +-0.47
230 2.11 +-0.32
260 1.79 +-0.27
290 1.04 +-0.28
320 0.779 +-0.228
360 0.909 +-0.155
400 0.693 +-0.104
460 0.433 +-0.067
520 0.173 +-0.043
600 0.119 +-0.031
720 4.33e-02 +-1.53e-02
880 -3.25e-02 +-3.03e-02
1080 -8.66e-03 +-1.90e-02
1280 8.66e-03 +-5.52e-03
1480 4.33e-03 +-3.72e-03
1680 4.33e-03 +-4.28e-03
1880 0.00e+00 +-2.84e-03
\END;
/*===================================================================*/
|