/*===================================================================*/ /* NRDF D1841 Data No.46 */ /*===================================================================*/ /* Bibliography */ /*===================================================================*/ \\BIB,46; D#=D1769; TITLE=/ Double-differential cross sections for the neutron production from heavy-ion reactions at energies E/A = 290-600 MeV /; PURPOSE=/ Systematic measurements of neutron-production cross sections from C, Ne, and Ar projectiles having E/A = 290-600 MeV on C, Cu, and Pb targets. /; ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2', T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5', Y.TOZAWA'5', K.NIITA'6'); INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5', 2JPNJPN'6'); /* '1' Department of Accelerator Physics and Engineering */ /* '2' Cyclotron and Radioisotope Center */ /* '4' National Superconducting Cyclotron Laboratory */ /* '5' Department of Physics */ /* '6' Research Organization for Information Science and Technology, Tokai, Naka, Ibaraki */ REF=PR/C; VLP=64(2001)054609; RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X, PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X); PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT); /*===================================================================*/ /* Experimental Conditions */ /*===================================================================*/ \\EXP,46; /* 2002-08-01 : Compiled, Am + Sr + On */ /* 2006-07-25 : Altered, On. Heading of data error corrected. Systematic uncertainties added. */ RTY=HEAVY-ION-RCT; ENR=NAT; CHM=ELM; PHYS-FORM=SLD; BAC=X; POL-TGT=0%; ALGN-TGT=0%; ACC=SYN'7'; /* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility INST-ACC=2JPNIRS; BEAM-INTNSTY=XMA'8'; /* '8' A few times 10e4-10e5 particles per pulse */ POL-PRJ=0%; DET-PARTCL=N; COINC=NO; ANT-COINC=NO; DET-SYS=(SCT'9',SCT'10',TOF); /* '9' NE102A plastic scintillator */ /* '10' NE213 liquid scintillator */ ERS-DET=XKEV'11'; /* '11' The energy resolutions are shown in Table I in reference. /* Experimental Method: - Time-of-flight RCT=C(20NE,N)X; PHQ=ENGY-SPEC; THK-TGT=1800MG/CM**2; INC-ENGY-LAB=400.0MEV/A; ANL=X'148'; /* '148' Moving-source model, QMD and HIC */ /*===================================================================*/ /* Descriptive Parameters */ /*===================================================================*/ \\DATA,46; SYS-ERR=10%'12'; /* '12' Uncertainty in detection efficiency */ INC-ENGY-LAB=400.0MEV/A; SYS-ERR=6.8%'149'; /* '149' Uncertainty in target thickness */ THTL=30DEG; /*===================================================================*/ /* Data Table */ /*===================================================================*/ \DATA; ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'150' (MEV) (MB/SR/MEV) (MB/SR/MEV) 5 0.00e+00 +-9.26e+00 6 5.46 +-7.50 7 8.73 +-6.00 8 5.46 +-6.41 9 5.46 +-5.07 10 1.09 +-5.50 20 3.71 +-1.06 40 3.77 +-0.85 60 2.18 +-0.97 80 4.15 +-0.93 100 5.19 +-1.00 120 4.09 +-1.04 140 4.42 +-0.96 160 4.04 +-0.93 180 1.75 +-1.00 200 3.93 +-0.81 230 4.04 +-0.73 260 3.75 +-0.52 290 3.13 +-0.50 320 2.40 +-0.39 360 1.83 +-0.33 400 1.42 +-0.19 460 0.782 +-0.144 520 0.328 +-0.084 600 0.191 +-0.043 720 8.19e-02 +-2.35e-02 880 0.00e+00 +-3.04e-02 1080 2.73e-02 +-1.10e-02 1280 5.46e-03 +-5.28e-03 1480 -3.28e-02 +-3.19e-02 1680 5.46e-03 +-1.22e-02 1880 5.46e-03 +-5.14e-03 \END; /*===================================================================*/ |