/* NRDF D1769 Data No.44 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,44;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,44;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=C(20NE,N)X;
PHQ=ENGY-SPEC;
THK-TGT=1800MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'142';
/* '142' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,44;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=6.8%'143';
/* '143' Uncertainty in target thickness */
THTL=10DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'144'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
15 4.97 +-1.83
25 3.90 +-1.90
35 4.44 +-1.66
45 3.90 +-1.55
55 3.49 +-1.88
65 5.11 +-1.84
75 5.11 +-2.08
85 3.90 +-1.97
95 1.21 +-1.07
105 4.84 +-2.01
125 2.29 +-1.84
145 5.31 +-2.02
165 9.07 +-2.37
185 10.4 +-2.7
205 10.5 +-3.1
235 21.1 +-2.8
265 19.1 +-2.5
295 19.4 +-2.2
325 20.3 +-1.9
365 19.0 +-1.4
405 14.5 +-1.1
465 10.8 +-0.7
525 4.91 +-0.48
605 2.55 +-0.30
725 1.14 +-0.15
885 0.294 +-0.058
1085 4.70e-02 +-2.70e-02
1285 6.72e-03 +-2.03e-02
1485 6.72e-03 +-1.33e-02
1685 6.72e-03 +-1.46e-02
1885 0.00e+00 +-1.22e-02
\END;
/*===================================================================*/
|