DARPE: Search Results
 /*===================================================================*/
 /* NRDF D0360 Data No.43                                             */
 /*===================================================================*/
 /* Bibliography                                                      */
 /*===================================================================*/
 \\BIB,43;
 D#=D360;
 TITLE=/STRUCTURE STUDIES OF 23NA FROM THE 20NE(ALPHA,P)23NA REACTION AT
        E-ALPHA=39.5MEV/;
 ATH=(C.R.BINGHAM'1,2',K.VAN DER BORG'1',R.J.DE MEIJER'1',
      A.VAN.DER WOUDE'1');
 INST-ATH=(2NEDGRN'1',1USATEN'2');
 REF=NP/A;
 VLP=323(1979)26;
 RCTS=(20NE(ALPHA,P)23NA);
 /*===================================================================*/
 /* Experimental Conditions                                           */
 /*===================================================================*/
 \\EXP,43;
 CHM=ELM;
 THK-TGT=200[300TORR'1';
 PHYS-FORM=GAS;
 POL-TGT=NO;
 ACC=(CYC);
 INST-ACC=2NEDGRN;
 INC-ENGY-LAB-RANGE=(39.5MEV);
 POL-PRJ=NO;
 DET-PARTCL=(P);
 DET-SYS=(MAG+PS-SI+CHTR-TLSCP);
 ERS-DET=(<20KEV'2',<50KEV'3');
 /*@25@*/
 /*@26@*/
 ANL=(DWBA'4',SHELL-MODEL'5');
 /*@27@*/
 /*@28@*/
 PHQ=(ANGL-DSTRN,DSIGMA/DOMEGA,EXC-ENGY,SPIN,PTY);
 RCT=96MO(P,P)X;
 PHQ=ENGY-SPEC;
 /*===================================================================*/
 /* Descriptive Parameters                                            */
 /*===================================================================*/
 \\DATA,43;
 INC-ENGY-LAB=39.5MEV;
 EXC-ENGY=14.26MEV;
 INC-ENGY-LAB=18MEV;
 SYS-ERR=X%'90';
 /* '90' Uncertainties associated with the normalization was
         estimated to be within 10% for each target. However, the
         relative uncertainties of the cross sections for different
         targets is believed to be less than 4%. */
 NORM=/ Absolute cross sections were determined by normalizing the
        experimental elastic cross sections to the optical model
        predictions at forward angles. The normalization factors for
        two sets of global optical model parameters were compared in
        order to estimate the uncertainties involved in this method.
        Optical model parameter [F.D. Becchetti, Jr. and G.W.
        Greenlees, Phys. Rev. 182(1969)1190] were adopted. /;
 EMT=P;
 THTL=30DEG;
 /*===================================================================*/
 /* Data Table                                                        */
 /*===================================================================*/
 \DATA;
 THTC DSIGMA/DOMEGA DELTA-DSIGMA/DOMEGA
 (DEG) (MB/SR) (MB/SR)
 /*FIG.6-(7)*/
 ENGY-EMT-CM-MIN ENGY-EMT-CM-MAX DSIGMA/DOMEGA/DE
 DELTA-DSIGMA/DOMEGA/DE'91'
 (MEV) (MEV) (MB/SR/MEV) (MB/SR/MEV)
 \END;
 /*===================================================================*/