/* NRDF D1769 Data No.42 */
/*===================================================================*/
/* Bibliography */
/*===================================================================*/
\\BIB,42;
D#=D1769;
TITLE=/ Double-differential cross sections for the neutron
production from heavy-ion reactions at energies E/A = 290-600
MeV /;
PURPOSE=/ Systematic measurements of neutron-production cross
sections from C, Ne, and Ar projectiles having E/A = 290-600
MeV on C, Cu, and Pb targets. /;
ATH=(Y.IWATA'1', T.MURAKAMI'1', H.SATO'2', H.IWASE'2', T.NAKAMURA'2',
T.KUROSAWA'2', L.HEILBRONN'3', R.M.RONNINGEN'4', K.IEKI'5',
Y.TOZAWA'5', K.NIITA'6');
INST-ATH=(2JPNIRS'1', 2JPNTOH'2', 1USABRK'3', 1USAMSU'4', 2JPNRIK'5',
2JPNJPN'6');
/* '1' Department of Accelerator Physics and Engineering */
/* '2' Cyclotron and Radioisotope Center */
/* '4' National Superconducting Cyclotron Laboratory */
/* '5' Department of Physics */
/* '6' Research Organization for Information Science and
Technology, Tokai, Naka, Ibaraki */
REF=PR/C;
VLP=64(2001)054609;
RCTS=(C(12C,N)X, CU(12C,N)X, PB(12C,N)X, C(20NE,N)X, CU(20NE,N)X,
PB(20NE,N)X, C(40AR,N)X, CU(40AR,N)X, PB(40AR,N)X);
PHQS=(ENGY-SPEC, ANGL-DSTRN, XSECTN, TOT-XSECTN, MLT);
/*===================================================================*/
/* Experimental Conditions */
/*===================================================================*/
\\EXP,42;
/* 2002-08-01 : Compiled, Am + Sr + On */
/* 2006-07-25 : Altered, On. Heading of data error corrected.
Systematic uncertainties added. */
RTY=HEAVY-ION-RCT;
ENR=NAT;
CHM=ELM;
PHYS-FORM=SLD;
BAC=X;
POL-TGT=0%;
ALGN-TGT=0%;
ACC=SYN'7';
/* '7' Heavy Ion Medical Accelerator in Chiba (HIMAC) facility
INST-ACC=2JPNIRS;
BEAM-INTNSTY=XMA'8';
/* '8' A few times 10e4-10e5 particles per pulse */
POL-PRJ=0%;
DET-PARTCL=N;
COINC=NO;
ANT-COINC=NO;
DET-SYS=(SCT'9',SCT'10',TOF);
/* '9' NE102A plastic scintillator */
/* '10' NE213 liquid scintillator */
ERS-DET=XKEV'11';
/* '11' The energy resolutions are shown in Table I in reference.
/* Experimental Method:
- Time-of-flight
RCT=PB(12C,N)X;
PHQ=ENGY-SPEC;
THK-TGT=9080MG/CM**2;
INC-ENGY-LAB=400.0MEV/A;
ANL=X'136';
/* '136' Moving-source model, QMD and HIC */
/*===================================================================*/
/* Descriptive Parameters */
/*===================================================================*/
\\DATA,42;
SYS-ERR=10%'12';
/* '12' Uncertainty in detection efficiency */
INC-ENGY-LAB=400.0MEV/A;
SYS-ERR=4.6%'137';
/* '137' Uncertainty in target thickness */
THTL=80DEG;
/*===================================================================*/
/* Data Table */
/*===================================================================*/
\DATA;
ENGY-EMT-LAB DSIGMA/DOMEGA/DE DELTA-DSIGMA/DOMEGA/DE'138'
(MEV) (MB/SR/MEV) (MB/SR/MEV)
5 361 +-9
6 238 +-7
7 181 +-6
8 142 +-6
9 127 +-4
10 78.6 +-4.0
15 42.0 +-1.0
25 24.1 +-0.8
35 16.2 +-0.7
45 13.6 +-0.6
55 9.37 +-0.60
65 7.70 +-0.58
75 7.86 +-0.50
85 5.02 +-0.52
95 5.19 +-0.42
105 3.51 +-0.32
125 3.10 +-0.29
145 2.01 +-0.19
165 1.34 +-0.21
185 0.920 +-0.173
205 0.753 +-0.145
235 0.558 +-0.089
265 0.223 +-0.089
295 0.112 +-0.032
325 5.58e-02 +-5.93e-02
365 0.167 +-0.034
405 4.18e-02 +-2.00e-02
465 5.58e-02 +-1.63e-02
525 2.79e-02 +-1.30e-02
605 4.18e-02 +-1.18e-02
725 0.00e+00 +-1.57e-02
885 2.09e-02 +-6.22e-03
1085 3.35e-02 +-7.95e-03
1285 1.67e-02 +-5.29e-03
1485 8.37e-03 +-1.05e-02
1685 8.37e-03 +-1.16e-02
1885 0.00e+00 +-2.45e-03
\END;
/*===================================================================*/
|